DOWNLOAD Sharp UP-800 (serv.man32) Service Manual ↓ Size: 5.14 MB | Pages: 68 in PDF or view online for FREE

Model
UP-800 (serv.man32)
Pages
68
Size
5.14 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
ECR / UP-800 In-Line (IRC) Instruction Manual
File
up-800-sm32.pdf
Date

Sharp UP-800 (serv.man32) User Manual / Operation Manual ▷ View online

15
List of downloading jobs (PGM2 mode)
Downloading Jobs
Description
Department preset data
Dept./PLU key preset data for direct depts./PLUs
PLU/EAN, link PLU, condiment, promotion, combo, PLU 
convert, crate and PLU information text preset data
PLU menu key preset data
Link PLU preset data
Condiment PLU preset data
EAN/ITF PLU convert preset data
Crate PLU preset data
Promotion preset data
Combo meal preset data
EAN non-PLU code format data
EAN press code format data
PLU information text preset data
Transaction preset data
Training text and training clerk/cashier No. preset data
Clerk preset and contactless clerk key preset data
Cashier preset data (Only for the clerk + cashier system)
Manager preset data
Date, time
Other preset data
Text preset data
Function menu key preset data
Device configuration preset data
Tax preset data
Customer preset data
Name & address preset data
Online preset data
Inline preset data
All PGM mode preset data excluding Online and Device 
Config preset data
Department preset data
Department price preset data
PLU/EAN, link PLU, condiment, promotion, combo, PLU 
convert, crate and PLU information text preset data
PLU/EAN price preset data
Link PLU preset data
Condiment PLU preset data
Crate PLU preset data
Promotion preset data
Combo meal preset data
PLU information text preset data
Transaction preset data
INITIAL D/L
(Preset data copying with 
existing data clearing)
MAINTENANCE D/L
(Preset data copying only)
Item
DEPT
DIRECT KEY
PLU/EAN
PLU MENU KEY
LINK PLU
CONDIMENT
PLU CONVERT
CRATE
PROMOTION
COMBO MEAL
EAN NON-PLU
PRESS CODE
PLU INFORMATION
TRANSACTION
TRAINING PRESET
CLERK
CASHIER
MANAGER
DATE/TIME
OPTION
MESSAGE
FUNC. MENU KEY
DEVICE CONFIG
TAX
CUSTOMER PRESET
NAME & ADDRESS
ONLINE PRESET
INLINE PRESET
ALL PGM
DEPT
DEPT PRICE
PLU/EAN
PLU/EAN PRICE
LINK PLU
CONDIMENT
CRATE
PROMOTION
COMBO MEAL
PLU INFORMATION
TRANSACTION
16
• The PLU/EAN file (INITIAL D/L and MAINTENANCE D/L) does not include stock data.
• The OPTION file includes the following data:
Optional feature preset, EAN deletion term, scale preset, happy hour, zero skip, general report
format, trans. report format, clerk report format, hourly report, stacked report, drawer alarm,
screen save time, customer control program, bonus point, bonus point redemption table and
auto key preset data.
• The MESSAGE file includes the following data:
Logo text, dept. group text, PLU group text, currency descriptor, VP text, slip text, slip footer,
payee name, Entertainment bill message, PLU hourly group text, scrolling message for pole
display, working time shift text and free text.
• The DEVICE CONFIG file includes the following data:
Journal printer, receipt printer, slip printer, report printer and kitchen printer#1-#9.
• The PLU/EAN file (INITIAL D/L and MAINTENANCE D/L) includes LINK PLU preset data.
• Initial downloading of all preset data (ALL PGM) should not be performed when totals exist in
the system. (The totalizers of the receiving satellite are cleared.)
• Performing individual initial D/L jobs will result in a non-reset error when sales data exists in the
satellite.
NOTE
17
In the IRC system, the following two types of GLU file allocation system are available: a centralized system
and an individual system.
In choosing the type of GLU file system, please consult your authorized SHARP dealer.
(1) Centralized GLU file system
In this system, the GLU file exists only in the master. All satellites in the IRC system can access the GLU file
in the master for registration.
The GLU file is accessed by satellites for the following purposes:
• New order or reorder
• Payment entry or temporary finalization
• Bill printing
• Slip printing
• Bill transfer/bill totalizing
• Bill separating
• Customer ordering
There are two types of GLU data transmission.
1) The GLU data is transmitted from the master to a satellite for GLU file look up (in case of a new
order/reorder). In this case, the GLU reserve counter* is retained at the master.
* The reserve counter reserves some records of GLU files to prevent a “LACKING MEMORY” error
in finalization.
2) The GLU data is transmitted from a satellite to the master upon finalization of a transaction (in case
of payment entry or temporary finalization).
The data transmitted from the satellite is once saved in the temporary GLU data receiving file and
then updated in the GLU file of the master. In this case, the GLU reserve counter is cleared at the
master.
If a satellite looks up the GLU file in the master or asks the master to update the file, the backup master
performs the same process as the master.
(2) Individual GLU file system
In this system, the master and satellites have their own GLU files and look up them for registration.
Therefore, no inline communications are made regarding GLU data.
9. Look-up and updating of the GLU file
18
In the IRC system, the following two systems for PLU/EAN stock control are available: a centralized system
and an individual system.
In choosing the type of PLU/EAN stock control system, please consult your authorized SHARP dealer.
Centralized system
Preset stock data is stored only in the master. Stock data in each satellite must be zero before a PLU/EAN
entry is made.
When a consolidated report is generated, stock data in respective satellites is consolidated into the stock file
in the master and calculated there.
The stock data calculated at the master is displayed or printed out and the stock data in each satellite is
reset to zero at the same time.
Individual system
The master and satellites store their own preset stock data. When a consolidated report is generated, the
stock data in the master and satellites is consolidated and displayed or printed out.
In the individual system, the consolidation does not affect the stock data in the master.
NOTE
10. PLU/EAN stock control
Page of 68