27
Programming the rate (
%
e
*: Rate
0.00 — 100.00 (% rate)
0.000000 — 999.999999 (Currency
exchange rate)
You must use a decimal point when setting rates that are fractional.
Programming the discount key amount (
-
Programming the percent rate limitation (
%
)
You can program the upper limit of percent rates for percent entries.  Percent entries that exceed the upper limit
may be overridden in the MGR mode.
10.00% can be entered as
1 0
or 
1 0 . 0 0
.  The 
.
key is needed only for
fractional entry.
Percentage limit
Ñ
10
15
.
00
É
Print
Key operation example
Ñ
10
Percentage limit (0.00 -100.00)
É
To program zero
To program for another percent key
or
∞ §
Discount amount
1000
-
É
Print
Key operation example
Discount amount (max. six digits)
É
-
To program zero
Percent rate
Currency exchange rate (0.606800)
10 
.
25
.
6068
e
É
Print
Key operation example
*Rate
or
e
É
§
To program another rate
To program zero
Programming for miscellaneous keys
4
28
Programming function parameters for 
-
and 
%
keys
+/- sign
Programming of the +/- sign assigns the premium or discount function for each key.
Item % / Item 
â
Percent/discount calculation for the individual department and PLU
Subtotal % / Subtotal 
â
Percent/discount calculation for the subtotals
Entry digit limit (For discount key only)
The limit is in effect for the REG-mode operations but can be overridden in the MGR mode.
*: Item:
Selection:
Entry:
A
+/- sign
+ (premium) sign
0
- (discount) sign
1
B
Item % / Item 
â
Enable
0
Disable
1
C
Subtotal % / Subtotal 
â
Enable
0
Disable
1
D
Entry digit limit*
0-7
* When programming for percent keys, always enter 0.
The default setting is ABCD = 1007 for 
-
key and 1000 for 
%
key.
Programming function parameters for 
e
key
Currency exchange rate entry selection
You can enable or disable preset and manual entry of currency exchange rate.
Number of digits after decimal point
Set the number of digits after decimal point which is printed on the receipts for currency exchange amount.
Foreign currency symbol
Foreign currency symbol for 
e
key is printed on a foreign currency exchange amount of which rate is preset by
programming.
*: Item:
Selection:
Entry:
A
Manual rate entry
Enable
0
Disable
1
B
Preset rate entry
Enable
0
Disable
1
C
Number of digits after decimal point
0-3
D
Foreign currency symbol
0
(space)
1
2
The default setting is ABCD = 0021.
*ABCD 
É
To program “0” for all items
e
From left, BCD
Sign
1006
- É
Print
Key operation example
*ABCD
or
,
-
É
§
To program for another key
To program “0” for all items
29
Programming an entry digit limit for 
'
î
r
and 
p
keys
The limit is in effect for REG-mode operation but can be overridden in the MGR mode.
When “0” is set, the operation of the corresponding key is prohibited.
• Be very careful not to enter a wrong number for the number entry after the first 
Ñ
key.  Be sure
to enter the number described in the "Procedure".
• You can continue programming until  
É
key is pressed for the programming described in this
section.  To continue programming, repeat from the first numeric key entry.
Setting the register number
When your store has two or more registers, it is practical to set separate register numbers for their identification.
Setting the consecutive number
The consecutive number is increased by one each time a receipt is issued.
Ñ
1000 
Ñ É
Print
Key operation example
Ñ
123 
Ñ É
Print
Key operation example
Programming various functions
5
Entry digit limit
8
Ŕʃ
Print
Key operation example
Entry digit limit(0-8)
or
É
To program  “0”
To program for another key
'
,
î
,
r p
From left, ABCD
0001
e É
Print
Key operation example
1
Ñ
Ñ
É
Register number (one to three digits)
To set the register number “0”
2
Ñ
Ñ
É
A number (one to four digits) that is one 
less than the desired starting number
To begin the count from 0001
30
Programming optional feature selection
You can enable or disable the operation of Paid out, Received-on account, Refund, No-sale, Void in the 
REG-mode, and also select if you enable fractional quantity entry or not.
* Item:
Selection:
Entry:
A
Paid-out in the REG-mode
Enable
0
Disable
1
B
Received on account in the REG-mode
Enable
0
Disable
1
C
Subtotal void in the REG-mode
Enable
0
Disable
1
D
Indirect void in the REG-mode
Enable
0
Disable
1
E
Direct void in the REG-mode
Enable
0
Disable
1
F
Refund entry in the REG-mode
Enable
0
Disable
1
G
No sale in the REG-mode
Enable
0
Disable
1
H
Fractional quantity entry
Enable
0
Disable
1
The default setting is ABCDEFGH = 00000000.
Programming print format
You can program; 
Printer type - Use printer as journal printer or for issuance of receipt 
If you select the journal printer type and complete journal information is mandatory, the receipt
ON/OFF function should be in the “ON” state.
Receipt print form - Detailed receipt print or summary receipt print
On the summary receipt print, the details of each item are not printed.
Date print selection
Consecutive number print selection
Zero skip for reports
Ñ
6
*ABCDEFGH
É
Ñ
To set “0” for all items
Ñ
00000100 
ÑÉ
Print
Key operation example
Ñ
5
*ABCDEFGH
É
Ñ
To set “0” for all items
Page of 48
Display