Panasonic TH-75EQ1W (serv.man2) Service Manual ▷ View online
INF-9
SECTION 1 SERVICE INFORMATION
<86/75/65/55/50/43EQ1>
Sub mode
Function
Aging
Carry out aging by the specified color.
On/Off -- (Default : Off White (100%))
Adjusts by [VOL(+/–)] button.
↓ White (100%)
↓ White (75%)
↓ White (50%)
↓ White (25%)
↓ Red
↓ Green
↓ Blue
↓ Yellow
↓ Magenta
↓ Cyan
↓ Black
* Disable the input selection and recall function
during the aging. This sub menu is not available
when the USB input is selected.
EDID
Operation
Checking and writing of EDID data for digital
inputs. (HDMI1, HDMI2, DVI-D)
EDID(VGA)
Write Protect
Factory use.
Local dimming
Factory use.
To exit the IIC mode
Press the [RETURN] button to return to the CAT mode menu
IIC
Aging
Panel Color
Panel Color
Off White (100%)
IIC
EDID Operation
EDID Verify : --
EDID Verify : --
IIC
EDID(VGA) Write Protect
Protect
Protect
IIC
Local dimming
On
On
INF-10
SECTION 1 SERVICE INFORMATION
<86/75/65/55/50/43EQ1>
3. 3. Software, EEPROM version and failure information (CD Mode)
• This model provides a power failure history function (5 histories) as PTCT information in the CD mode.
• On the self check for a signal system, only one history is displayed (it will disappear after self checking). The PTCT displays
up to 5 histories and they do not disappear even if the self check has been done. You can see the history of power failure
any time.
1. Display the CAT mode (Refer to 3.1.).
2. The CAT mode menu appears on the screen. Select the [CD Mode] menu with [pq] buttons and press the [MUTE] button
for more than 3 seconds to enter the CD mode.
For further information of PTCT failure code, refer to the item [4.2. Self check of power system].
To exit the CD mode
Press the [RETURN] button to return to the CAT mode menu
01. 04. 09. 0D. 04.
First failure
Second failure
3rd latest failure
2nd latest failure
Latest failure
Second failure
3rd latest failure
2nd latest failure
Latest failure
About PTCT information
Firmware version of Main MCU
EEPROM version Destination code
EEPROM address
EEPROM data
Firmware version of Sub MCU
Panel size
Firmware version of FRC (Only for 86EQ1/75EQ1)
MAC address
Product serial number
PTCT failure history information
(Refer to the below.)
EEPROM version Destination code
EEPROM address
EEPROM data
Firmware version of Sub MCU
Panel size
Firmware version of FRC (Only for 86EQ1/75EQ1)
MAC address
Product serial number
PTCT failure history information
(Refer to the below.)
CAT Panel sys.8.2
IIC Mode
CD Mode
NW Mode
SD Mode
MS Mode
ID Mode
INF-11
SECTION 1 SERVICE INFORMATION
<86/75/65/55/50/43EQ1>
3. 4. Network connection check mode (NW Mode)
1. Display the CAT mode (Refer to 3.1.).
2. The CAT mode menu appears on the screen. Select the [NW Mode] menu with [pq] buttons and press the [ENTER] button
to enter the NW mode.
3. Press the [ENTER] button to start the network connection check. The check result will be displayed in a few seconds.
To exit the NW mode
Press the [RETURN] button to return to the CAT mode menu
CAT Panel sys.8.2
IIC Mode
CD Mode
NW Mode
SD Mode
MS Mode
ID Mode
Displays the result of [TEST]
• OK
: There is a response of PING
• BSY
: On test executing
• G_NG
: No response of PING
• L_NG
: A LINK state is not established
INF-12
SECTION 1 SERVICE INFORMATION
<86/75/65/55/50/43EQ1>
3. 5. Status display mode (SD Mode)
• In the SD mode, internal temperature, cumulated used time and cumulated power-on times can be checked.
1. Display the CAT mode (Refer to 3.1.).
2. The CAT mode menu appears on the screen. Select the [SD Mode] menu with [pq] buttons and press the [ENTER] button
to enter the SD mode.
To exit the SD mode
Press the [RETURN] button to return to the CAT mode.
•
Parameter
WT : Cumulated power-on times
PT : Cumulated used time (hour)
•
Condition : Internal temperature (ºC)
BL : Back Light setting value *
CAT Panel sys.8.2
IIC Mode
CD Mode
NW Mode
SD Mode
MS Mode
ID Mode