INF-35
SECTION 1 SERVICE INFORMATION
<VZ585N/VW545N/VX615N/VZ580/VW540/VX610>
5. 5. Lamp log data
5. 5. 1. Log data format
The lamp log data consists of 4 byte as below.
TIME HOURS (upper 8 bit) TIME HOURS (lower 8 bit)
TIME MINUTES (8 bit)
EVENT CODE (8 bit)
4 byte
- Data length : 4 byte fixed
- Maximum events : 1,984 events
- Time stamp : Lamp usage hours converted in Normal mode.
(Example of output lamp log data)
Lamp memory type: VX2
Lamp memory version:100
Lamp model number:TXZVL01VLLZ
Lamp lot number:CTK
Lamp serial number:1234
Lamp starting voltage:66.0
LAMP(NORMAL)(VZ570):     9 h 20 m
LAMP(NORMAL)(VZ580):     9 h 20 m
LAMP(ECO)   (VZ570):     9 h 50 m
LAMP(ECO1)  (VZ580):     0 h 20 m
LAMP(ECO2)  (VZ580):     9 h 30 m
LAMP ON:    51 times
LAMP IGNITION FAIL:     0 times
LAMP ERROR:     4 times
00 00 03 11:     0 h  3 m LAMP OFF
00 00 03 d0:     0 h  3 m 72 VOLT
00 00 0a 31:     0 h 10 m LAMP1 ON (Floor)(Lamp Power:Normal)
00 00 0b d2:     0 h 11 m 76 VOLT
00 00 19 11:     0 h 25 m LAMP OFF
00 00 19 d0:     0 h 25 m 72 VOLT
00 00 1e 31:     0 h 30 m LAMP1 ON (Floor)(Lamp Power:Normal)
00 00 1e 11:     0 h 30 m LAMP OFF
00 00 28 31:     0 h 40 m LAMP1 ON (Floor)(Lamp Power:Normal)
00 00 28 11:     0 h 40 m LAMP OFF
00 00 32 31:     0 h 50 m LAMP1 ON (Floor)(Lamp Power:Normal)
    :
    :
    :
-  Actual lamp used time (Normal) displayed on the "STATUS" when the lamp is 
installed in the model PT-VZ570 series.
-  Actual lamp used time (Normal) displayed on the "STATUS" when the lamp is 
installed in the model PT-VZ580 series.
-  Actual lamp used time (Eco) displayed on the "STATUS" when the lamp is 
installed in the model PT-VZ570 series.
-  Actual lamp used time (Eco1) displayed on the "STATUS" when the lamp is 
installed in the model PT-VZ580 series.
-  Actual lamp used time (Eco2) displayed on the "STATUS" when the lamp is 
installed in the model PT-VZ580 series.
- Times of lamp turing-on .
- Times of lamp turning -on fail.
- Times of lamp fail.
Data written at the factory shipping
Operation log
Refer to "5.5.2. Lamp log table" for further details.
Logs the time with normal converted used time.
Lamp voltage (Vla) is memorized at 1 minutes later when 
the lamp turns on, and at 0 to 5 minutes before when the 
lamp turns off.
Lamp voltage (Vla) cannot be memorized if the lamp-on 
period is less than 1 minute.
INF-36
SECTION 1 SERVICE INFORMATION
<VZ585N/VW545N/VX615N/VZ580/VW540/VX610>
5. 5. 2. Lamp log table
EVENT
DESCRIPTION
CODE(hex)
Lamp On 
LAMP1 ON (Floor)(Lamp Power:Eco2) 
1
LAMP1 ON (Floor HIGHLAND)(Lamp Power:Eco2) 
5
Lamp Off
LAMP OFF 
11
LAMP IGNITION ERR NOT START
14
LAMP IGNITION ERR VLA
15
LAMP IGNITION ERR TEMP.
18
LAMP IGNITION ERR LOW VLT
19
LAMP FAIL NOT START
1b
LAMP FAIL VLA
1c
LAMP FAIL TEMP.
1f
LAMP FAIL LOW VLA
20
Lamp power 
change
LAMP POWER CHANGE NORMAL 
23
LAMP POWER CHANGE ECO1
25
LAMP POWER CHANGE ECO2
26
LAMP LOG RESET 
27
Warning
WARNING INTAKE TEMP. 
28
WARNING LAMP AROUND TEMP.
2a
WARNING CLOG TEMP.
2c
Error
ERROR INTAKE TEMP.
2d
ERROR LAMP AROUND TEMP.
2f
ERROR CLOG TEMP.
30
Lamp On (extra)
LAMP1 ON (Floor)(Lamp Power:Normal) 
31
LAMP1 ON (Floor HIGHLAND)(Lamp Power:Normal) 
35
LAMP1 ON (Ceiling)(Lamp Power:Eco2) 
45
LAMP1 ON (Ceiling HIGHLAND)(Lamp Power:Eco2) 
49
LAMP1 ON (Ceiling)(Lamp Power:Normal) 
55
LAMP1 ON (Ceiling HIGHLAND)(Lamp Power:Normal) 
59
Lamp Off (extra)
LAMP IGNITION ERR ETC 
a0
LAMP FAIL ETC 
a1
Lamp On (extra)
LAMP1 ON (Floor)(Lamp Power:Eco1)
aa
LAMP1 ON (Floor HIGHLAND)(Lamp Power:Eco1)
ac
LAMP1 ON (Ceiling)(Lamp Power:Eco1)
b2
LAMP1 ON (Ceiling HIGHLAND)(Lamp Power:Eco1)
b4
-  Voltage at lamp 
on in 1 min.
-  Voltage at lamp 
off before 5 min.
40 VOLT 
c0
42 VOLT 
c1
:
166 VOLT 
ff
INF-37
SECTION 1 SERVICE INFORMATION
<VZ585N/VW545N/VX615N/VZ580/VW540/VX610>
Bit
Displayed logs
Type of errors
Error occuring condition
Note
UPPER
31
30
29
28 Temp error[IN]
Intake temp. error
Intake temp. reached a specified error temp.
27 Temp error[OUT]
Exhaust temp. error
Exhaust temp. reached a specified error temp.
26
25 DC OUT error
USB power supply error
Over current was detected.
24 Error[Lamp time]
Lamp used time error
Lamp used time reached a specified used time.
23
22 LAMP error
Lamp error
Failed to turn on the lamp, Lamp failed, Lamp sw was 
opened.
21 Iris error
Iris error
Iris error was detected.
:
:
13 Temp warning[IN]
Intake temp. warning
Intake temp. reached a specified warning temp.
12 Temp warning[OUT]
Exhaust temp. warning
Exhaust temp. reached a specified warning temp.
11
10 Dirty air filter
Filter clog warning
Filter clogged
9
8
7
6 Warning[Lamp time]
Lamp used time warning
Lamp used time reached (Lamp time - 200H)
5 Filter Clog error
Filter clog warning
Filter clog error was detected.
:
:
0
LOWER
31
:
:
24 Ballast error
Ballast communication error
Failed to communicate with ballast.
:
:
12 FAN7 error
POWER FAN ERROR
Fan rotating speed came down to a specified value.
11 FAN6 error
EXHAUST FAN ERROR
Fan rotating speed came down to a specified value.
10 FAN5 error
LAMP FAN ERROR
Fan rotating speed came down to a specified value.
9
8 FAN3 error
INTAKE3 FAN ERROR
Fan rotating speed came down to a specified value.
7 FAN2 error
INTAKE2 FAN ERROR
Fan rotating speed came down to a specified value.
6 FAN1 error
INTAKE1 FAN ERROR
Fan rotating speed came down to a specified value.
5
4
3 LAMP IGN error
Lamp ignition error
Failed to turn on the lamp (Fails 3 times)
2 EEPROM[LAMP]
Lamp memory communication 
error
Failed to communicate to lamp memory
1
0
5. 6. 2.  How to read the returned value and the self-diagnosis serial control command.
  Use the command "QVX:ERRS1" to get the information of Self-diagnosis for this model.
  The returned value provides the 64bit self-diagnosis information as follows.
  (Table below shows no error occurs)
 
UPPER bit
LOWER bit
31
30
29
• • • • • • • • •
1
0
31
30
• • • • • • • • •
2
1
0
ERRS1=
N
N
N
• • • • • • • • •
N
N
N
N
• • • • • • • • •
N
N
N
   The returned value "N" indicates normal and "E" indicates error status. The first bit 0 starts from right and it ends by 64th bit 
at left.
  Example:  If the self-diagnosis information is inquired under the condition of the power fan error, the "E" will appear on 12th 
bit as the below.
 
"E" will appear on lower 12th bit. 
UPPER bit
LOWER bit
31
30
29
• • • • • • • • •
1
0
31
30
• • • •
12
• • • •
2
1
0
ERRS1=
N
N
N
• • • • • • • • •
N
N
N
N
• • • •
E
• • • •
N
N
N
5. 6. Error cord of system log
5. 6. 1. Error code table
INF-38
SECTION 1 SERVICE INFORMATION
<VZ585N/VW545N/VX615N/VZ580/VW540/VX610>
5. 7. Troubleshooting
* The letters in the left of inspection items indicate the P.C. Boards related to their respective descriptions.
* Please check items with the interlock switch on. 
■ Power does not turn ON. (ON(G)/STANDBY(R) LED does not light in red)
■ Lamp does not turn ON. 
Check the connection of each connector
  AC inlet - P11, P12, P01, P03 - K8R
NG
Connect the cables properly
Check the connection of each connector on A-P.C Board and 
lamp.
Check the lamp fixing screws.
NG
Connect the cables properly
A Disconnect the connector [P02], check the short circuit between 
pins (14)-(15), (7)-(15), (12)-(15) of connector K8R.
NG
A Check or replace [A] P.C.Board
Check the lamp condition
NG
Replace the lamp
Is each thermal sensor operating in normal?
NG
Check each thermal sensor and connection
Is each fan rotating when the projector turns on?
NG
Check each fan and connection
Next page
OK
OK
OK
OK
OK
OK
K Confirm the fuse [F601]
NG
K Replace fuse
P Check or replace [P] P.C.Board
P Check the short circuit of Q611, Q612, Q613, Q614
NG
Replace the shorted parts
OK
OK