INF-27
SECTION 1 SERVICE INFORMATION
<VZ585N/VW545N/VX615N/VZ580/VW540/VX610>
1)  Turn on the projector.
2)  Press the <MENU> button on the remote control or the control panel.
 
f
The main menu screen is displayed.
3)  Press as to select [PROJECTOR SETUP].
4)  Press the <ENTER> button.
 
f
The 
[PROJECTOR SETUP] screen is displayed.
5)  Press as to select [FILTER COUNTER].
6)  Press the <ENTER> button.
 
f
The 
[FILTER COUNTER] screen is displayed. 
7)  Press as to select [FILTER COUNTER RESET] and press the <ENTER> button.
8)  When the confirmation screen is displayed, press 
qw to select [OK], then press the <ENTER> button.
 
f
The [PROJECTOR SETUP] menu → [FILTER COUNTER] → [FILTER COUNTER] is displayed as “0H”.
Note
 
f
The lamp unit is a consumable component. Refer to “When to replace the lamp unit”  for details 
about the replacement cycle.
When purchasing the optional Replacement Lamp Unit (Model No.: ET-LAV400), consult your dealer.
It is recommended to replace the lamp unit by a professional technician. Consult your dealer for details.
Warning
Replace the lamp unit after the lamp has cooled (after waiting at least one hour).
The high temperature inside the cover will cause burns.
Notes on the replacement of the lamp unit
 
f
A Phillips screwdriver is required when replacing the lamp unit.
 
f
Since the luminous lamp is made of glass, it may burst if dropped or hit with a hard object. Handle with care.
 
f
Do not disassemble or modify the lamp unit.
 
f
When replacing the lamp unit, be sure to hold it by the handle because its surface is pointed and its shape is 
protruded.
 
f
The lamp may rapture. Replace the lamp unit carefully so that the glass fragments of the lamp do not scatter. 
While attaching the projector to the ceiling, do not work right under the lamp unit or do not conduct work while 
your face is near the lamp unit.
 
f
The lamp contains mercury. When disposing of used lamp units, contact your local authorities or dealer for 
correct methods of disposal.
Attention
 
f
Panasonic takes no responsibility for any damage or malfunction of the product resulting from use of lamp units which are not manufactured 
Note
 
f
The model numbers of accessories and optional accessories are subject to change without prior notice.
4. 3. 2. Lamp unit
INF-28
SECTION 1 SERVICE INFORMATION
<VZ585N/VW545N/VX615N/VZ580/VW540/VX610>
The lamp unit is a consumable component. Since its brightness gradually decreases over time, it is necessary to replace the 
lamp unit regularly. The estimated duration before replacement is 5 000 hours, but the lamp may go off before reaching to 
5 000 hours, depending on the characteristics of the individual lamp, usage conditions, and the installation environment. It is 
recommended that the Replacement Lamp Unit be prepared earlier.
If you continue to use the lamp unit after 5 000 hours has elapsed, the lamp turns off automatically after approximately 10 
minutes, as it may cause malfunction of the projector.
On screen display
REPLACE LAMP
LAMP indicator
On screen display
REPLACE LAMP
LAMP indicator
Over 4 800 hours
The message is displayed for 30 seconds. If you 
press any button on the control panel or the remote 
control within 30 seconds, the message disappears. Lights in red (even in stand-by mode).
Over 5 000 hours The message remains displayed until you press any 
button.
Note
• To predict the lamp unit replacement time, convert the runtime of [NORMAL], [ECO1] and [ECO2], which are set from the    
  [PROJECTOR SETUP] menu → [LAMP POWER], to the equivalent runtime of [[NORMAL] respectively. After checking    
   the runtime of [NORMAL], [ECO1] and [ECO2] displayed in the [PROJECTOR SETUP] menu → [STATUS] → [RUNTIME] →  
   [LAMP (ET-LAV400)], calculate the converted runtime by referring to “Formula for lamp unit replacement time 
   (rough estimate)”.
• The lamp unit replacement time of 5 000 hours is a rough guideline instead of a guarantee.
Lamp cover
Lamp cover 
Handles
Fig. 1
Fig. 2
1)  After turning off the projector, remove the plug from the outlet.
 
f
Wait at least one hour and make sure the lamp unit and surroundings have cooled down. 
2)  Remove the lamp cover. (Fig. 1)
 
f
turns freely, slowly slide the lamp cover in the direction of the arrow, and then remove it.
3)  Remove the lamp unit. (Fig. 2)
 
f
×3) with a Phillips screwdriver in the counterclockwise direction until it 
turns freely, and remove lamp unit.
 
f
Hold the handle of the lamp unit and take it straight out.
 
f
4)  Press in the new lamp unit while paying attention to the insertion position.
 
f
The connector part may be damaged if it is 
pressed by force.
5)  Use a Phillips screwdriver to firmly tighten the lamp unit fixing screws (x3).
 
f
Make sure to attach the lamp unit securely.
6)  Attach the lamp cover.
i)  Perform Step 
2) in the reverse order to attach the lamp cover.
ii)  Use a Phillips screwdriver to firmly tighten the lamp cover fixing screw (x1).
 
f
Make sure to attach the lamp cover slowly and securely.
Note
 
f
When you replace the lamp unit with a new one, the projector resets the runtime of the lamp unit automatically.
How to replace the lamp unit
Attention
 
f
When the projector is mounted on a ceiling, do not work with your face close to the lamp unit.
 
f
 
f
Attach the lamp unit and the lamp cover securely.
INF-29
SECTION 1 SERVICE INFORMATION
<VZ585N/VW545N/VX615N/VZ580/VW540/VX610>
4. 3. 3. Calculation formula of lamp runtime
The lamp runtime that is displayed in the [STATUS] is real time.
The following conversion is required to calculate the rough estimate for lamp replacement.
Formula for lamp replacement time (rough estimate)
=  “Lamp runtime of [NORMAL] ×1”+ “Lamp runtime of [ECO1]” × 5/6 + “Lamp runtime of [ECO2]” × 5/7
Lamp cover
Lamp cover 
Handles
Fig. 1
Fig. 2
1)  After turning off the projector, remove the plug from the outlet.
 
f
Wait at least one hour and make sure the lamp unit and surroundings have cooled down. 
2)  Remove the lamp cover. (Fig. 1)
 
f
turns freely, slowly slide the lamp cover in the direction of the arrow, and then remove it.
3)  Remove the lamp unit. (Fig. 2)
 
f
×3) with a Phillips screwdriver in the counterclockwise direction until it 
turns freely, and remove lamp unit.
 
f
Hold the handle of the lamp unit and take it straight out.
 
f
4)  Press in the new lamp unit while paying attention to the insertion position.
 
f
The connector part may be damaged if it is 
pressed by force.
5)  Use a Phillips screwdriver to firmly tighten the lamp unit fixing screws (x3).
 
f
Make sure to attach the lamp unit securely.
6)  Attach the lamp cover.
i)  Perform Step 
2) in the reverse order to attach the lamp cover.
ii)  Use a Phillips screwdriver to firmly tighten the lamp cover fixing screw (x1).
 
f
Make sure to attach the lamp cover slowly and securely.
Note
 
f
When you replace the lamp unit with a new one, the projector resets the runtime of the lamp unit automatically.
How to replace the lamp unit
Attention
 
f
When the projector is mounted on a ceiling, do not work with your face close to the lamp unit.
 
f
 
f
Attach the lamp unit and the lamp cover securely.
INF-30
SECTION 1 SERVICE INFORMATION
<VZ585N/VW545N/VX615N/VZ580/VW540/VX610>
4. 4. Security password
4. 4. 1. Control device password
• To revert to the factory default password (AAAA), perform the following operations while the screen prompting input of 
   [MENU LOCK PASSWORD] is displayed.
  1.  Press the [AUTO SETUP] button on the remote control or the control panel of the projector for at lease 3 seconds.
  2. Press the [▼] button for at least 3 seconds.
      The password will be initialized.
4. 4. 2. Initial security password
• Initial password : Press [p  q  p  q ] button sequentially and press [ENTER] button.
  If the initial password has been changed, ask user to have it.