INF-15
SECTION 1 SERVICE INFORMATION
< RZ21K / RS20K >
9. LIGHT ADJUST
 •  Used to take a optical adjustment. (Factory use only)
   - LIGHT SELECT
     Select the LD to turn on. Press the [ENTER] key to switch.
     -- ALL : Both of LD1/LD2 turn on (Default)
     -- LD1 : Only LD1 turns on 
     -- LD2 : Only LD2 turns on
     *The selection will be reset to "ALL" after turning off the projector.
   - LIGHT ADJUSTMENT MODE
     Select a lighting pattern when taking optical adjustment.
   - TEST PATTERN
     Select a test pattern (white raster) when taking optical adjustment.
10. INDICATOR SETTING
 •  Set this when you want to turn off the indicator LED.
    - INDICATOR MODE
     -- NORMAL : The indicator lights normally. (Default)
     -- OFF : The indicator will be forcibly turned off. 
     -- TIMEOUT : The indicator turns off when there is no operation for a fixed time.
   - NO ACTIVITY TIME
     Set the time to turn off when INDICATOR MODE setting is TIMEOUT.
     You can set up to 15 minutes in 1 minute increments. (default setting is 15 MIN.)
     *If INDICATOR MODE setting is NORMAL or OFF, it will be grayed out.
   - 7SEG DISPLAY MODE
     Set this when you want to turn off the Self-diagnosis display (7SEG) on the control panel.
     -- ON : Self-diagnosis will be displayed. (Default)
     -- OFF : Turns off the Self-diagnosis display.
     -- TIMEOUT : Self-diagnosis display turns off when there is no operation for a fixed time.
   - DIRECTION
     Set whether to vertical flip the self-diagnosis display (7 SEG) on the control panel.
     -- AUTO : Automatically displays according to the installation status of the projector. (Default)
     -- NORMAL : Self-diagnosis display not turns flip vertical.
     -- FLIPPED : Self-diagnosis display turns flip vertical.
11. COMMAND CONTROL TIMEOUT
 •  Set up the communication specifications of the command control.
   - 0SEC : 1 Command 1 session mode. (Default)
   - 30SEC : Keeps a session for 30 seconds.
12. PHOTO SENSOR CALIBRATION
•  This is to calibrate the luminance sensor circuit. 
   This calibration is necessary when the [A]-P.C Board, EEPROM (IC3711) or [M3]- P.C. Board is replaced.
   Refer to the chapter SECTION 3 (Adjustments) for the procedure.
INF-16
SECTION 1 SERVICE INFORMATION
< RZ21K / RS20K >
3. 3. 2. Additional function of each menu
1. [PICTURE] menu
 • [AI WINDOW] is added to the setting of the sub menu [DYNAMIC CONTRAST].
   Sets up the APL detective area. (AUTO/MANUAL, further settings are available in MANUAL mode)
2. [POSITION] menu
 • [DVI EQUALIZER] is added to a sub menu. 
    When noise contamination to DVI input caused by long cable or external device, set this item so that the noise decreas-
es. (AUTO/LOW/MID/HIGH)
3. [DISPLAY OPTION] menu
 • The following items are added to [SDI IN] sub menu.
   [XYZ TO RGB SETTING]
   - FACTORY SETTING : Uses the value of FACTORY Yxy conversion factor to the original data of XYZ → RGB.
   - MEASURED : Uses the value of MEASURED Yxy conversion factor to the original data of XYZ → RGB.
   - REC709 : Uses the value of REC709 Yxy conversion factor to the original data of XYZ → RGB.
   - DCI P3 : Uses the value of DCI P3 Yxy conversion factor to the original data of XYZ → RGB.
   [XYZ TEST PATTERN]
   - WHITE : 10% ~ 100%
   - DARK GRAY : 1 ~ 10
   - COLOR : Red/Green/Blue/Cyan/Magenta/Yellow of 1 ~ 2
INF-17
SECTION 1 SERVICE INFORMATION
< RZ21K / RS20K >
4. [PROJECTOR SETUP] menu
(1) The following two items are added to the sub-menu. 
   [COOLING CONDITION]
   - Fan control can be set manually. (Usually set to [AUTO].)
   [HIGH ALTITUDE MODE]
   - Altitude can be set manually. (Usually set to [AUTO].)
(2) [ZOOM BACKLASH CORRECTION] is added to [LENS CALIBRATION] of sub menu [LENS].
   This menu is displayed only when a stepping motor attached projection lens.
   -  Adjust when the accuracy of position numerical information is reduced by repeating the zoom operation.
   -  Do not adjusted in normal.
   -  Refer to chapter SECTION 3 (Adjustments).
(3)  [CALIBRATION TIME] is added to [BRIGHTNESS CONTROL SETUP] of sub menu [BRIGHTNESS CONTROL].
   Measure the brightness and color at specified time.
   Normally, setting is unnecessary because it is automatically measured.
LENS
LENS TYPE
LENS MEMORY
LENS INFORMATION SETTING
ET-D75LE10
LENS HOME POSITION
ACTIVE FOCUS OPTIMIZER
LENS CALIBRATION
MENU SELECT
SUB MENU
ENTER
LENS CALIBRATION:ET-D75LE10
SHIFT/FOCUS/ZOOM
SHIFT/FOCUS
21 -       +
ZOOM
ZOOM BACKLASH CORRECTION
MENU SELECT
ADJUST
a
INF-18
SECTION 1 SERVICE INFORMATION
< RZ21K / RS20K >
(5)   [SHUTTER COUNTER] is added in sub menu [INITIALIZE].
   -  Initialize the count if replaced the mechanical shutter.
(6) The following items are added to the sub menu [STATUS].
 1) Page 2
     • The sensor value is added.
   - VERTICAL TILT    Vertical angle
   - HORIZONTAL TILT    Horizontal angle
   - P.SENSOR 
  Luminance sensor
(4)  In the [BRIGHTNESS CONTROL STATUS] sub menu, [DETAILED INFORMATION] is displayed by pressing the [ENTER] 
key.  The detailed information of brightness control can be checked.