DOWNLOAD Panasonic PT-RZ21KE / PT-RS20K Service Manual ↓ Size: 31.52 MB | Pages: 127 in PDF or view online for FREE

Model
PT-RZ21KE PT-RS20K
Pages
127
Size
31.52 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / 3-CHIP DLP BASED PROJECTOR
File
pt-rz21ke-pt-rs20k.pdf
Date

Panasonic PT-RZ21KE / PT-RS20K Service Manual ▷ View online

INF-11
SECTION 1 SERVICE INFORMATION
< RZ21K / RS20K >
1. DYNAMIC GAMMA MODE
 • Setting of the DYNAMIC GAMMA operation.
   - ON : Enable the Dynamic gamma function. (Default setting)
   - OFF : Disable the Dynamic gamma function.
2. 3DCMS
 • Setting of the 3D Color Management System operation.
   - ON : Enable the 3D Color Management system function. (Default setting)
   - OFF : Disable the 3D Color Management system function.
3. SELF CHECK
 • Self-diagnosing information Displays.
⑫ --- LD sub driver 
⑬ --- FRC
⑭ --- Power
------------ DEVICE CHECK ------------
⑮ --- Intake air temperature (Celsius/Fahrenheit) 
⑯ --- DMD temperature (Celsius/Fahrenheit)
⑰ --- Exhaust air temperature (Celsius/Fahrenheit) 
⑱ --- LD1 temperature (Celsius)
⑲ --- LD2 temperature (Celsius)
⑳ --- FPGA2 temperature (Celsius)
㉑ --- LD1 check (1: normal / 0: abnormal / *: intentional Off)
㉒ --- LD2 check (1: normal / 0: abnormal / *: intentional Off)
① --- Model number
② --- Serial number
------------ Firmware version ------------
③ --- Main 
microprocessor
④ --- Sub 
microprocessor
⑤ --- Digital Link
⑥ --- FPGA (FPGA1/FPGA2/FPGA3)
⑦ --- CPLD
--- Formatter [R]
⑨ --- Formatter [G]
⑩ --- Formatter [B]
⑪ --- LD driver
SELF CHECK
MODEL        : RZ21K
SERIAL NO.   : SW1234567890
---------- VERSION --------------
1/3
MAIN         : 1.00.00
SUB          : 1.00.00
DIGITAL LINK : 1.30.20.5
FPGA         : 01.01/02.02/03.03
CPLD         : 01.01
FM(R)        : 00.0400.00
FM(G)        : 00.0400.00
FM(B)        : 00.0400.00
LD DRIVER    : 01.00/01.00
q�w  CHANGE
DEVICE CHECK : OK
SELF CHECK
LD SUB       : 01.00/01.00
FRC          : 1.00.00
POWER        : 1.00.00
2/3
---------- DEVICE CHECK ---------
OK : AIR TEMP  123/456
OK : DMD TEMP  123/456
OK : OUT TEMP  123/456
OK : LD1 TEMP  123
OK : LD2 TEMP  123
OK : FPGA TEMP 123
OK : LD1 1 1 1 1 1 1
OK : LD2 1 1 1 1 1 1
q�w  CHANGE
DEVICE CHECK : OK
FPGA No.
PCB
Ref No.
FPGA1
A
IC3508
FPGA2
DG
IC5001
FPGA3
G
IC6522
INF-12
SECTION 1 SERVICE INFORMATION
< RZ21K / RS20K >
– Device check (OK: Normal, NG: abnormal)
㉓ --- Fan [1] check (1: normal / 0: abnormal) 
㉔ --- Fan [2] check (1: normal / 0: abnormal)
㉕ --- Luminance sensor check (detected value)
㉖ --- Luminance sensor check (initial value)
㉗ --- Atmospheric pressure sensor check (hPa/Celsius)
㉘ --- Angle sensor check (Horizontal angle / Vertical angle)
㉙ --- Shutter control check 
(Opening and shutting times [Failure times])
 
SELF CHECK
OK : FAN[1] 1111 1111 1111 1111 1111
OK : FAN[2] 1111 1
OK : PHOTO Y 123456.7(R=+123/G=+123/B=+123)
3/3
OK : PHOTO INIT
OK : ATM 1234/567
OK : ANGLE H -123.4/ V +123.4
OK : SHUTTER 65535 [    0]
q�w  CHANGE
DEVICE CHECK : OK
Sensor
PCB
Ref No.
Luminance
M3
SN1401
Atmospheric pressure
RM
IC1501
Angle
A
IC3751
• Items 
 to 
 indicates the status of "NG" or "OK". If the "NG" indicates in red, the projector has an abnormal- 
  ity now. If the "OK" indicates in red, the projector had an abnormality in the past and operates normally now. 
• To clear the error status, press the [MENU] key in the SELF CHECK mode, the confirmation window will ap- 
   pear and select [OK] to clear. 
 
 
 
 
 
 
• This must be done after finishing the repair or maintenance.
 CLEAR ERROR INFOMATION?
OK
CANCEL
w
 How to read the status of light source
---  LD1 check (1: normal / 0: abnormal / *: intentional Off)
---  LD2 check (1: normal / 0: abnormal / *: intentional Off)
LD1-1 --- LD1-2 --- LD1-3 --- LD1-4 --- LD1-5 --- LD1-6 ---
OK : LD1 1 1 1 1 1 1
LD2-1 --- LD2-2 --- LD2-3 --- LD2-4 --- LD2-5 --- LD2-6 ---
OK : LD2 1 1 1 1 1 1
• Intentional Off 
  If one of the laser device has an open failure for blue or yellow light, the projector cuts off the other laser 
  device intentionally to maintain the proper white balance. It will return the normal operation when the LD 
  unit which has an open failure device actually is replaced with new one.
INF-13
SECTION 1 SERVICE INFORMATION
< RZ21K / RS20K >
w
 LD units location
LD1-3
LD1-2
LD1-1
LD2-3
LD2-2
LD2-1
LD1-6
LD1-5
LD1-4
LD2-6
LD2-5
LD2-4
w
 How to read the status of fans
㊱–  Fan[1] check (1: normal / 0: abnormal)
㊲–  Fan[2] check (1: normal / 0: abnormal)
R
A
D
IA
TO
--
-
R
A
D
IA
TO
--
-
R
A
D
IA
TO
--
-
R
A
D
IA
TO
--
-
R
A
D
IA
TO
--
-
R
A
D
IA
TO
--
-
E
X
H
AU
ST 
--
-
E
X
H
AU
ST 
--
-
D
M
D
 IN
TA
K
E 1
 -
--
D
M
D
 IN
TA
K
E 2
 -
--
H
E
AT
PI
PE
 ---
CI
R
CU
LA
TI
O
N
 1
 -
--
CI
R
CU
LA
TI
O
N
 2
 -
--
C
O
LO
PR
IS
--
-
C
O
LO
PR
IS
--
-
C
O
LO
PR
IS
--
-
C
O
LO
PR
IS
--
-
C
IR
C
U
IT
 IN
TA
K
E 1
 -
--
C
IR
C
U
IT
 IN
TA
K
E 2
 -
--
LD 
D
R
IV
ER 
--
-
OK : FAN[1] 1111 1111 1111 1111 1111
PU
M
1(
D
M
D
-R
) -
--
PU
M
2(
D
M
D
-G
) -
--
PU
M
3(
D
M
D
-B
) -
--
PU
M
4(
LD
1) 
--
-
PU
M
5(
LD
2) 
--
-
OK : FAN[2] 1111 1
w
 Fans location
EXHAUST1
RADIA
TOR3
HEA
TPIPE
RADIA
TOR1
DMD INT
AKE1
CIRCUIT
 INT
AKE1
CIRCUIT
 INT
AKE2
CIRCULA
TION1
CIRCULA
TION2
COLOR PRISM2
COLOR PRISM3
COLOR PRISM4
COLOR PRISM1
LD DRIVER
DMD INT
AKE2
RADIA
TOR5
RADIA
TOR2
RADIA
TOR4
RADIA
TOR6
EXHAUST2
Fan/Pump error
No. of detection
Projector operation
Cooling fans
1 pcs
Decrease the LD output and
keep projector-on.
more than 2 pcs Shutdown
Liquid cooling pump
1 pcs
Shutdown
INF-14
SECTION 1 SERVICE INFORMATION
< RZ21K / RS20K >
w
 Cooling pumps location
PUMP4 (LD1)
PUMP3 (DMD-B)
PUMP2 (DMD-G)
PUMP1 (DMD-R)
PUMP5 (LD2)
4. POWER OFF MESSAGE
 • Setting of the shutter function with standby operation
     - SHUTTER KEEP:  When pushing the standby key while the shutter mode is on, the projector keeps the shutter 
mode on and sets into standby mode.
     - SHUTTER OPEN:  When pushing the standby key while the shutter mode is on, the projector opens the shutter and 
displays the "Power OFF confirmation message". (Default setting)
5. ERROR OSD
 •   Enables to display the error information of the LIGHT indicators on the screen (It is useful when using the projector with 
rear projection mode)
     - ON :  "LIGHT1\LIGHT2 ERROR" is displayed on the screen if the lighting error occurs. (It will disappear when any of 
the control buttons is pressed.)
     - OFF : No message is displayed on the screen if the lighting error occurs. (Default setting)
6. ELECTRIC CONVERGENCE
 • Aligns the convergence electrically. Refer to chapter SECTION 3 (Adjustments)
     - OFF : Invalid. (Default setting)
     - NORMAL : Correct in horizontal / vertical direction in 1 pixel unit.
     - FINE :  Correct in vertical / horizontal direction with 0.25 pixel unit for each corner of the screen (upper left / upper 
right / lower left / lower right).
7. MECHANICAL CONVERGENCE
 • Aligns the convergence mechanically procedure is displayed on the projection screen. 
   Refer to chapter SECTION 3 (Adjustments)
8. MODEL
 This setting is necessary when the A-P.C. Board is replaced with new one.
   • If you can copy EEPROM data from old A-P.C. Board, this setting is unnecessary.
   • This model setting is effective after power restart.
Page of 127