ADJ-5
SECTION 3 ADJUSTMENTS
< RZ21K / RS20K >
1. 3. Convergence adjustment
1. 3. 1. Electrical convergence adjustment
• This function is to align each R/G/B convergence in pixels electrically.
1. Project the internal crosshatch pattern and check the misalignment of each R/G/B component.
2. Enter the service mode, and select submenu [ELECTRICAL CONVERGENCE] of [EXTRA OPTION].
3. Select the mode of adjustment with the [ q ][ w ] button and press the [ENTER] button.
- OFF : Does not perform electrical convergence adjustment.
- NORMAL : Adjust the entire screen up, down, left, and right in units of 1 pixels.
- FINE : Adjust the four corners of the screen in the center direction in units of 0.25 pixels.
4. Select the color to convergence adjustment and press the [ENTER] button.
5. Select the item to be adjusted and adjust with [ q ][ w ][ a ][ s ] button.
• Press [ a ][ s ] buttons to adjust VERTICAL, and [ q ][ w ] buttons
to adjust HORIZONTAL.
• Press [ a ][ s ] buttons to select the adjustment point on screen,
and [ q ][ w ] buttons to adjust each items.
6. After completing the alignment, exit the adjustment mode by pressing [MENU] button.
In FINE mode, select [STORE] on the color selection screen and press the [OK] button on the confirmation screen.
The setting value will be saved at this time.
• Because of using the entire pixels of DMD, the edge pixel of the projected screen is missing when adjusted.
• [FINE] Mode adjustment is a temporary adjustment function until mechanical convergence adjustment is
performed. Since the geometry correction circuit is used, the sharpness of the screen deteriorates.
EXTRA OPTOPN
DYNAMIC GAMMA MODE
3DCMS
3DCMS
SHUTTER KEEP
ON
ON
ON
OFF
NORMAL
0SEC.
SELF CHECK
POWER OFF MESSAGE
ERROR OSD
POWER OFF MESSAGE
ERROR OSD
ELECTRICAL CONVERGENCE
MECHANICAL CONVERGENCE
MODEL
MODEL
INDICATOR SETTING
LIGHT ADJUST
COMMAND CONTROL TIMEOUT
PHOTO SENSOR CALIBRATION
PHOTO SENSOR CALIBRATION
MENU SELECT
SUB MENU
ENTER
ELECTRICAL CONVERGENCE:NORMAL
RED
RED
GREEN
BLUE
BLUE
MENU SELECT
SUB MENU
ENTER
ELECTRICAL CONVERGENCE:FINE
RED
RED
GREEN
BLUE
BLUE
MENU SELECT
SUB MENU
ENTER
STORE
NORMAL mode
FINE mode
ELECTRICAL CONVERGENCE:NORMAL
VERTICAL
RED
0
HORIZONTAL
0
ADJUST
ELECTRICAL CONVERGENCE:FINE
RED
UPPER LEFT
VERTICAL
O.00
O.00
O.00
O.00
O.00
O.00
O.00
O.00
O.00
O.00
O.00
O.00
O.00
O.00
O.00
HORIZONTAL
UPPER RIGHT
VERTICAL
HORIZONTAL
LOWER LEFT
VERTICAL
HORIZONTAL
LOWER RIGHT
VERTICAL
HORIZONTAL
MENU SELECT
CHANEG
NORMAL mode
FINE mode
Adjustment item
Adjustment point
UPPER LEFT
VERTICAL
Upper left corner of the screen downward
HORIZONTAL
Upper left corner of the screen to rightward
UPPER RIGHT VERTICAL
Upper right corner of the screen downward
HORIZONTAL
Upper right corner of the screen leftward
LOWER LEFT
VERTICAL
Lower left corner of the screen upward
HORIZONTAL
Lower left corner of the screen to rightward
LOWER RIGHT VERTICAL
Lower right corner of the screen upward
HORIZONTAL
Lower right corner of the screen leftward
STORE
OK
CANCEL
CHANGE
EXECUTE
ENTER
ADJ-6
SECTION 3 ADJUSTMENTS
< RZ21K / RS20K >
1. 3. 2. Mechanical convergence adjustment
• Use the B component as a standard and align each R/G component onto it mechanically.
• Perform only the [ELECTRICAL CONVERGENCE] (NORMAL mode) adjustment usually, because advanced skills are
necessary for the adjustment.
1. Project the internal crosshatch pattern and check the misalignment of each R/G/B component.
2. Enter the service mode, and select submenu [MECHANICAL CONVERGENCE] of [EXTRA OPTION].
3. Select color and press the [ENTER] button. The adjustment procedure will be displayed on the screen.
1) Loosen 4 fixing screws on the DMD plate you intend to adjust 45-degree turn.
• Please set [ELECTRICAL CONVERGENCE] to "OFF" beforehand.
EXTRA OPTOPN
DYNAMIC GAMMA MODE
3DCMS
3DCMS
SHUTTER KEEP
ON
ON
ON
OFF
OFF
OFF
0SEC.
SELF CHECK
POWER OFF MESSAGE
ERROR OSD
ELECTRICAL CONVERGENCE
POWER OFF MESSAGE
ERROR OSD
ELECTRICAL CONVERGENCE
MECHANICAL CONVERGENCE
MODEL
INDICATOR SETTING
LIGHT ADJUST
COMMAND CONTROL TIMEOUT
PHOTO SENSOR CALIBRATION
PHOTO SENSOR CALIBRATION
MENU SELECT
SUB MENU
ENTER
MECHANICAL CONVERGENCE
GREEN
GREEN
RED
MENU SELECT
SUB MENU
ENTER
GREEN
1/5
NEXT
ENTER
Loosen 4 screws 45-degree turn
RED
1/5
NEXT
ENTER
Loosen 4 screws 45-degree turn
DMD plate (G)
Fixing screw
DMD plate (R)
Fixing screw
ADJ-7
SECTION 3 ADJUSTMENTS
< RZ21K / RS20K >
2) Adjust the horizontal position by turning the H adjustment screw.
3) Adjust the vertical position by turning two V adjustment screws in the
same direction.
4) Adjust the tilt by turning two V adjustment screws in the opposite direction.
5) Repeat steps 2) to 4), until the green and red lines converge properly.
6) After completing the adjustment, tighten 4 fixed screws on the DMD plate.
GREEN 2/5
NEXT
ENTER
Adjust horizontal
GREEN 3/5
NEXT
ENTER
Adjust vertical
GREEN 4/5
NEXT
ENTER
Adjust tilt
RED 2/5
NEXT
ENTER
Adjust horizontal
RED 3/5
NEXT
ENTER
Adjust vertical
RED 4/5
NEXT
ENTER
Adjust tilt
GREEN 2/5
NEXT
ENTER
Adjust horizontal
GREEN 3/5
NEXT
ENTER
Adjust vertical
GREEN 4/5
NEXT
ENTER
Adjust tilt
RED 2/5
NEXT
ENTER
Adjust horizontal
RED 3/5
NEXT
ENTER
Adjust vertical
RED 4/5
NEXT
ENTER
Adjust tilt
GREEN 2/5
NEXT
ENTER
Adjust horizontal
GREEN 3/5
NEXT
ENTER
Adjust vertical
GREEN 4/5
NEXT
ENTER
Adjust tilt
RED 2/5
NEXT
ENTER
Adjust horizontal
RED 3/5
NEXT
ENTER
Adjust vertical
RED 4/5
NEXT
ENTER
Adjust tilt
GREEN
5/5
END
ENTER
Fasten 4 screws
RED
5/5
END
ENTER
Fasten 4 screws
H-Adj. Screw(R)
H-Adj. Screw(G)
V-Adj. Screw(R)
V-Adj. Screw(G)
V-Adj. Screw(R)
V-Adj. Screw(G)
ADJ-8
SECTION 3 ADJUSTMENTS
< RZ21K / RS20K >
1. 3. 3. Usage of special wrench
• It is very hard to access the fixing screws on the G-DMD unit in the state of DMD block mounting on the set. We provide a
special wrench for convergence adjustment.
Special wrench part no.: DPKW1001ZA
• This special wrench can also be used for DZ21K2 / RZ12K / RZ31K / RQ13K / RQ32K series.
DMD plate (G) fixing screws
Special wrench
Special wrench
Click on the first or last page to see other PT-RZ21KE / PT-RS20K service manuals if exist.