53
8.4.5.
STARTING SENSOR Board
(1) Remove the Base Plate. (See 8.3.1.)
(2) While unlocking the claw, remove the STARTING SENSOR
Board from the scanner.
Board from the scanner.
(3) Disconnect the connector.
Reassembling Note:
Make sure to support the board with the claw after
inserting the tip of the board into the hole to fix the
sensor position.
inserting the tip of the board into the hole to fix the
sensor position.
54
Note: Arm (for Starting Sensor)
1. Disassembling
(1) Remove the STARTING SENSOR Board. (See 8.4.5.)
(2) Remove the Conveyor Roller. (See 8.3.3.)
(3) Rotate the arm in the direction of the arrow (1),
and pull it up in the direction of the arrow (2).
2. Reassembling: Arm with Spring
55
8.4.6.
RELAY Board
8.4.7.
DOUBLE FEED (R) Board
(1) Remove the Top Cover. (See 8.2.6.)
(2) Release the 2 bands that secure the wire cables.
(2) Release the 2 bands that secure the wire cables.
(3) Remove the 3 screws that secure the RELAY Board
Shield-plate.
Shield-plate.
(4) Disconnect the 2 connectors and flat-cable.
(5) Remove the 4 screws to release the RELAY Board from the
Shield-plate.
Shield-plate.
(1) Remove the Base Plate. (See 8.3.1.)
(2) Remove the screw, and then pull the DOUBLE FEED (R)
Board's Assembly upward.
Board's Assembly upward.
56
8.4.8.
ULTRASONIC SENSOR (R) Board
(3) Remove the screw on the DOUBLE FEED (R) Board.
(4) Disconnect the 2 connectors.
Reassembling Note:
When reassembling the DOUBLE FEED (R) Board, make
sure to match the guide of the board with the slit of the
Relay Shield Plate.
sure to match the guide of the board with the slit of the
Relay Shield Plate.
(1) Remove the Base Plate. (See 8.3.1.)
(2) Remove the screw, and then disconnect the connector.