Panasonic KV-S1065C / KV-S1046C (serv.man3) Service Manual ▷ View online
49
(6) Remove the spacer from the Paper Feed Roller Shaft, while
unlocking the poly slider.
Then, remove the gear from the shaft.
unlocking the poly slider.
Then, remove the gear from the shaft.
Reassembling Note:
Make sure to re-assemble the Feed Roller Assy., paying
attention to the arrow marked on each assy.
attention to the arrow marked on each assy.
50
8.4.
Circuit Board Assemblies
8.4.1.
PANEL Board
8.4.2.
PAPER SENSOR Board
(1) Remove the Top Cover. (See 8.2.6.)
(2) Unlock the 2 claws to release the PANEL Board from the
Top Cover.
Top Cover.
(1) Remove the Top Cover. (See 8.2.6.)
(2) While unlocking the 2 claws, remove the PAPER SENSOR
Board from the scanner.
Board from the scanner.
(3) Disconnect the connector.
Note: Disassembling Arm (for Paper Sensor)
(1) Open the Double-feed Prevention Cover.
(2) Push out the arm in the direction of the arrow after
releasing the tip of the arm from the hook of the cover.
releasing the tip of the arm from the hook of the cover.
51
8.4.3.
DOOR DETECTION Board
(1) Remove the Top Cover. (See 8.2.6.)
(2) Remove the 2 screws on the DOOR DETECTION Board.
(3) Disconnect the connector.
Reassembling Note:
Make sure to install the DOOR DETECTION Board so that
the hole position of the board matches with the
projection portion on the Conveyor-chassis Upper.
Reassembling Note:
Make sure to install the DOOR DETECTION Board so that
the hole position of the board matches with the
projection portion on the Conveyor-chassis Upper.
52
8.4.4.
CONTROL Board
(1) Remove the Bottom Cover. (See 8.2.3.)
(2) Remove the screw that secures the USB connector.
(3) Disconnect the 2 connectors.
(4) Remove the 7 screws on the CONTROL Board.
Reassembling Note:
When reassembling the CONTROL Board, attach the
screw that secures the USB connector before securing
the bottom of the board with the 7 screws.
When reassembling the CONTROL Board, attach the
screw that secures the USB connector before securing
the bottom of the board with the 7 screws.
(5) While holding the CONTROL Board, disconnect the
2 connectors and the flat-cable to release the board from the
scanner.
2 connectors and the flat-cable to release the board from the
scanner.
Click on the first or last page to see other KV-S1065C / KV-S1046C (serv.man3) service manuals if exist.