8.12. Low outdoor ambient temperature control
A. Purpose
To protect air conditioner from damage under the low outdoor ambient temperature.
(Low outdoor ambient temperature < -10°C [14°F]).
B. During low outdoor ambient temperature control activated, other compressor & outdoor fan motor control is ignored. (Apply
to all operation modes.)
C. Basic operation
 1. Protection control
Outdoor unit stop operation regardless operation mode setting.
33
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
Note:
# : Fan motor off condition depends on:
a. 1 min over after FM ON. And
b. Air temperature < -3°C (26.6°F) during 1 min.
So the FM Off time is between 5 sec. to 1 min. 5 sec.
D. Indoor condition during protection control
Operation mode
I/D FM
Protection control;
Cooling
Setting speed
Compressor reverse
rotation protection
Soft dry
Cooling zone
Setting speed
Compressor reverse
rotation protection
Soft dry zone
S Lo
Compressor reverse
rotation protection
Heating
Speed
depends
on
I/D
piping temperature
Nil
Automatic
Depends on mode judgement.
#1
#1: I/D fan speed and protection control depends on the operation mode. Then, the condition follow operation mode in table above.
34
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
9 Operating Instructions (U.S.A. Models)
SAFETY PRECAUTIONS
Before operating, please read the following
“Safety Precautions” carefully.
● To prevent personal injury, injury to others and
property damage, the following instructions must be
followed.
● Incorrect operation due to failure to follow instructions
will cause harm or damage, the seriousness of which
is classified as follow:
!
  Warning
This sign warns of death or serious injury.
!
  Caution
This sign warns of damage to property.
● The instructions to be followed are classified by the
following symbols:
This symbol (with a white background) denotes an
action that is PROHIBITED.
These symbols (with a black background) denote
actions that are COMPULSORY.
OFF
■ Installation Precautions
Warning
● This room air conditioner must be
earthed.
Improper grounding could cause
electric shock.
● Ensure that the drainage piping is
connected properly.
Otherwise, water will leak out.
● Do not install the unit in a
potentially explosive atmosphere.
Gas leak near the unit could cause
fire.
● Do not install, remove and reinstall the unit by
yourself.
Improper installation will cause leakage, electric
shock or fire. Please engage an authorized dealer
or specialist for the installation work.
!
  Caution
■ Operation Precautions
!
  Warning
This sign warns of death or serious injury.
● Do not operate with wet hands.
● Do not insert finger or other objects into the
indoor or outdoor units.
● Do not expose directly to cold air for a long
period of time.
● Use specified power cord.
● If abnormal condition (burnt smell, etc.)
occurs, switch off the power supply.
!
  Caution
This sign warns of injury.
● Do not wash the unit with water.
● Do not use for other purposes such as
preservation.
● Do not use any combustible equipment at
airflow direction.
● Do not sit or place anything on the outdoor
unit.
● Switch off the power supply before cleaning.
● Ventilate the room regularly.
● Pay attention as to whether the installation
rack is damaged after a long period of usage.
● Switch off the power supply if the unit is not
used for a long period.
OFF
OFF
■ Accessories
 Remote Control
 Remote Control Holder
 Two RO3 (AAA) dry-cell batteries or equivalent
 Air Purifying Filter
(Air Purifying Filter)
(Solar Refreshing Deodorizing Filter)
NAME OF EACH PART
■ Indoor Unit
1 Front Panel
2 Air Intake Vent
3 Air Outlet Vent
4 Vertical Airflow Direction Louver
5 Horizontal Airflow Direction Louver
(manually adjusted)
6 Indicator Panel
1 Auto Operation Button
(when the front panel is opened)
2 Economy Mode Indicator – GREEN
3 Powerful Mode Indicator – ORANGE
4 Power Indicator
GREEN
5 Quiet Mode Indicator
ORANGE
6 Timer Mode Indicator
ORANGE
 Indoor Unit
(when the front panel is opened)
1 Front Panel
2 Air Filters
3 Air Purifying Filter
■ Outdoor Unit
1 Air Intake Vents
2 Ground Terminal
(Inside cover)
3 Piping
4 Conduit
5 Drain Hose
6 Air Outlet Vents
1
2
3
4
5
POWER
POWER
TIMER
TIMER
QUIET
QUIET
POWERFUL
POWERFUL
POWERFUL
POWERFUL
ECONOMY
ECONOMY
ECONOMY
ECONOMY
POWER
POWER
TIMER
TIMER
QUIET
QUIET
6
2
1
3
1
6
2
3
4
5
POWER
POWER
TIMER
TIMER
QUIET
QUIET
POWERFUL
POWERFUL
POWERFUL
POWERFUL
ECONOMY
ECONOMY
ECONOMY
ECONOMY
POWER
POWER
TIMER
TIMER
QUIET
QUIET
1
2 3
6
5
4
CH
EC
K
TEM
P
AU
T
AUT
O
ON
OFF
AU
T
AUT
O
HE
A
HEA
T
T
DR
DR
Y
FAN
AN
COO
L
COOL
FA
N
AN
AU
T
AUT
O
F
RE
SE
T
BAT
TE
RY
CLO
CK
MO
DE
SLE
EP
ECO
NOM
Y
FAN
 SPE
ED
AIR
 SW
IN
G
OF
F
CAN
CEL
ON
SE
T
Ste
p
1
2
3
TIM
ER
+
QU
IET
OFF
/O
N
35
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
● How  to Insert the Batteries
1
Slide down the remote control cover completely
to remove it.
2
Insert the batteries
– Be sure the direction is correct
– 12:00 on display - flashing
• Set the current time (CLOCK) immediately to
prevent battery exhaustion.
3
Re-install the remote control cover by inserting it
in the side groves and pushing inward.
● About the batteries
• Can be used for approximately one year.
● Observe the following when replacing the
batteries
• Replace with new batteries of the same type.
• Do not use rechargeable batteries (Ni-Cd).
• Remove the batteries if the unit is not going to be
used for a long period.
CHECK
AU
TO
OF
AU
TO
HEA
T
DR
Y FA
N
COOL
FA
N
AU
TO
AU
TO
RESET
CLOCK
AIR
 SW
IN
G
OF
F
CAN
CEL
1
2
3
TIM
ER
PO
WERFUL
AU
TO
MA
NU
AL
ECO
NOM
Y
SLE
ON
SE
T
FAN SPEED
MO
DE
2
1
1.5V
1.5V
NAME OF EACH PART
■ Remote Control
● Remote Control Signal
• Make sure it is not obstructed.
• Maximum distance : 10 m (32.8 ft.).
• Signal received sound :
One short beep or one long beep.
● Notes for Remote Control
• Do not throw or drop.
• Do not get it wet.
• Certain types of fluorescent lamps may affect
signal reception. Consult your dealer.
CHECK
TEMP
AUTO
ON
OFF
AUT
AUTO HEA
HEAT
DR
DRY FAN
AN
F
COOL
COOL
FAN
AUTO
RESET CLOCK
MODE
POWERFUL
ECONOMY
FAN SPEED
AIR SWING
OFF
CANCEL
ON
SET
1
2
3
TIMER
OFF/ON
QUIET
AUTO
MANUAL
#
!
$
%
^
$
*
&
3
5
8
7
9
0
6
4
(
2
1
1 Signal Transmitter
2 Operation Display
3 Quiet Mode Operation Button
4 Room Temperature Setting Button
(Illuminating button)
5 Operation Mode Selection Button
6 Economy Mode Operation Button
7 Auto Airflow Direction Button
8 ON-Timer Button
9 OFF-Timer Button
0 Reset Point
(Press with fine-tipped object to clear the memory)
! OFF/ON Button
(Illuminating button)
@ Powerful Mode Operation Button
# Fan Speed Selection Button
$ Manual Airflow Direction Selection Button
% Timer Set Button
^ Timer Cancellation Button
& Time-Setting Button
* Clock Button
( Remote Control Cover
PREPARATION BEFORE OPERATION
■ Indoor Unit
1
Open the front panel
2
Remove the air filters
3
Fit the air purifying filters in place
4
Insert the air filters
5
Close the front panel
■ Remote Control – To set the current time
1
Press 
1.
2
Then press 
2 to increase or decrease the time.
3
Press 
1 again.
Set time on display will light up.
CHECK
AUTO
AUTO HEAT
DRY FAN
COOL
FAN
AUTO
RESET CLOCK
FAN SPEED
AIR SWING
OFF
CANCEL
ON
SET
1
2
3
TIMER
AUTO
MANUAL
1
2
5
1
3
4
2
Operation
Cooling
Soft Dry
Cooling Model
COOL –>   75°F ~ 78°F
DRY
–>       2°F ~   4°F
lower than the
room temperature
HOW TO OPERATE
■ To start the operation
• Press 
1.
• POWER indicator (green) on the indoor unit will light
up.
• To stop, press once more.
■ Setting Mode
• Press 
2 to select:-
Cooling Model
AUTO
– Automatic Operation
COOL
– Cooling Operation
DRY
– Soft Dry Operation
FAN
– Air Circulation Operation
Heat Pump Model
AUTO
– Automatic Operation
HEAT
– Heating Operation
COOL
– Cooling Operation
DRY
– Soft Dry Operation
Operation
Cooling
Soft Dry
Heating
Indoor
temperature
73°F
68°F
■ Setting Temperature
• Press 
3 to increase or decrease the temperature.
• The temperature can be set between 60°F ~ 86°F.
• Recommended temperature:
• During AUTO Operation, press 
3 to select:-
• Operation with 4°F higher than the standard
temperature.
• Operation with the standard temperature.
• Operation with 4°F lower than the standard
temperature.
● Standard Temperature
Cooling Model
• Once the Automatic Operation is selected, the indoor
temperature sensor operates automatically to select
the desired operation mode with Cooling or Soft Dry.
• After the operation mode has been selected, the
mode does not change.
Heat Pump Model
• At the beginning of the automatic operation, Heating,
Cooling or Soft Dry is automatically selected according
to the indoor temperature.
• The operation mode changes every hour, when
necessary.
Standard
temperature
77°F
72°F
Standard
temperature
77°F
72°F
70°F
Indoor
temperature
73°F
OFF
ON
HE
A
HEA
T
DR
DR
Y F
AN
AN
CO
OL
COOL
CHECK
TE
M
P
AU
T
AUT
O
AUT
O
FAN
AU
T
AUT
O
RESET
CLOCK
AIR
 S
W
IN
G
OFF
CA
NCEL
1
2
3
TIM
ER
OFF
/ON
QU
IET
AU
TO
MAN
UA
L
ECO
NOM
Y
POWERFUL
ON
SE
T
FAN SPEED
MO
DE
2
3
5
1
6
4
Heat Pump Model
COOL –> 75°F ~ 78°F
DRY
–>   2°F ~   4°F
lower than the
room temperature
HEAT –> 68°F ~ 75°F
36
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
Page of 82
Display

Click on the first or last page to see other CS-A9CKPG / CU-A9CKP6G / CS-A12CKPG / CU-A12CKP6G (serv.man2) service manuals if exist.