DOWNLOAD Panasonic CS-A9CKPG / CU-A9CKP6G / CS-A12CKPG / CU-A12CKP6G (serv.man2) Service Manual ↓ Size: 8.78 MB | Pages: 82 in PDF or view online for FREE

Model
CS-A9CKPG CU-A9CKP6G CS-A12CKPG CU-A12CKP6G (serv.man2)
Pages
82
Size
8.78 MB
Type
PDF
Document
Service Manual / Supplement
Brand
Device
Air Conditioner / ROOM AIR CONDITIONER
File
cs-a9ckpg-cu-a9ckp6g-cs-a12ckpg-cu-a12ckp6g-sm2.pdf
Date

Panasonic CS-A9CKPG / CU-A9CKP6G / CS-A12CKPG / CU-A12CKP6G (serv.man2) Service Manual / Supplement ▷ View online

29
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
 1. Vertical Airflow Direction
  • The louver swings up and down as shown above.
  • The louver does not swing when the Indoor Fan stops
during operation at the upper limit.
Heating Mode
  • When the intake air temp. reaches 38°C (100.4°F), the
louver is changed from upper to lower limit. When the
intake air temp falls to 35°C (95°F), the louver is
changed from lower to upper limit.
 2. Horizontal Airflow Direction
  • The louver can be selected between 14° - 36° (as
shown above) when pressing Manual Airflow Direction
Selection Button.
  • The louver can be selected between 0° - 61° (as shown
above)
when
pressing
Manual
Airflow
Direction
Selection Button.
8.9. Airflow Direction Control
Cooling, Ion and Soft Dry Mode
  • The left and right airflow direction louvers can be adjusted manually.
30
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
8.10. Powerful Mode Operation
Purpose of this operation is to be obtain the setting temperature quickly.
 1. Cooling and Soft Dry Mode
  • When the Powerful Mode is set, the set temperature will be automatically decreased 3°C (37.4°F) against the present
setting temperature (Lower temperature: 16°C [60.8°F]). This operation automatically will be running under SHi Fan speed
(cooling), Lo- Fan Speed (Soft Dry).
  • Vertical Airflow Direction:-
In “Manual” setting, the vane will automatically shift down 10° lower than previous setting.
In “Auto” setting, the vane will automatically swing up and down. However the upper and lower limit will be shifted 10°
downward.
 2. Heating Mode
  • When the Powerful Mode is set, the set temperature will be automatically increased 3°C (37.4°F) against the present setting
temperature (Higher temperature: 30°C [86°F]).
  • The Fan Speed will shift as shown below:
  • Vertical Airflow Direction:-
In “Manual” setting, the vane will automatically shift down 5° lower than previous setting.
In “Auto” setting, the vane will automatically shift between upper and lower limit depending on the intake air temperature as
Heating Mode, Airflow Direction Auto-Control. However the upper and lower limit will be shifted 5° downward.
 3. Powerful mode will operate for 15 minutes only.
 4. Powerful Mode will stop if:
  • Powerful mode button is pressed again.
  • Stopped by ON / OFF switch.
  • Timer-off activates.
  • Quiet mode button is pressed.
  • Operating mode is changed.
31
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
8.11. Economy Mode Operation
Purpose of this operation is to save or reduced electrical power consumption of the room air conditioner.
However consumer is advised to use Economy Mode operation after the room temperature reaches the desired temperature.
 1. Cooling and Soft Dry Mode
  • When the Economy Mode is set, the set temperature will be automatically increased 0.5°C (32.9°F) against the present
setting temperature. This operation automatically will be running under Lo- Fan speed.
  • Vertical Airflow Direction:-
In “Manual” or “Auto” setting, the vane will automatically change to Auto Air Swing.
 2. Heating Mode
  • When the Economy Mode is set, the temperature will be automatically decreased 0.5°C (32.9°F) against the present setting
temperature.
  • The Fan Speed will shift as shown below:
  • Vertical Airflow Direction:-
In “Manual” or “Auto” setting, the vane will automatically change to Auto Air Swing.
 3. Economy Mode will stop if:
  • Economy mode button is pressed again.
  • Stopped by ON / OFF switch.
  • Timer-off activates.
  • Powerful mode button is pressed.
  • Fan Speed control button is pressed.
  • Quiet mode button is pressed ON.
  • Operating mode is changed.
  • Air Swing condition is changed.
32
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
Page of 82
Display

Click on the first or last page to see other CS-A9CKPG / CU-A9CKP6G / CS-A12CKPG / CU-A12CKP6G (serv.man2) service manuals if exist.