DOWNLOAD Panasonic CS-A9CKPG / CU-A9CKP6G / CS-A12CKPG / CU-A12CKP6G (serv.man2) Service Manual ↓ Size: 8.78 MB | Pages: 82 in PDF or view online for FREE

Model
CS-A9CKPG CU-A9CKP6G CS-A12CKPG CU-A12CKP6G (serv.man2)
Pages
82
Size
8.78 MB
Type
PDF
Document
Service Manual / Supplement
Brand
Device
Air Conditioner / ROOM AIR CONDITIONER
File
cs-a9ckpg-cu-a9ckp6g-cs-a12ckpg-cu-a12ckp6g-sm2.pdf
Date

Panasonic CS-A9CKPG / CU-A9CKP6G / CS-A12CKPG / CU-A12CKP6G (serv.man2) Service Manual / Supplement ▷ View online

Cooling Operation Time Diagram
17
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
Quiet Operation Control
(For Cooling Mode or cooling region of Soft Dry Mode)
  • Purpose of this operation is to provide quite cooling operation compare to normal operation.
  • When the Quiet Mode is set at the remote control, Quiet Mode LED illuminates, the sound level will be automatically decreased
2 dB (Lo), decreased 3 dB (Hi, Me), against the present sound level operation.
  • Quiet setting of fan speed rpm refer to Indoor Fan Speed Control.
  • Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1h 30 min (1h QLo, 30 min QLo + 50).
After that, it goes back to Lo cool (However Quiet LED remains on).
  • Manual Airflow Direction:-
  − RPM control during Lo cool
  − RPM control during Hi & Me cool
  • Auto Airflow Direction:-
  • Quiet Mode Operation will stop if:-
  − Quiet mode button is pressed again.
  − Stopped by ON/OFF switch.
  − Timer OFF activates.
  − Powerful mode button is pressed.
  − When change mode to Air Circulation mode.
18
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
Time Delay Safety Control
Starting Current Control
Anti-Freezing Control
Compressor Reverse Rotation Protection Control
Compressor Protection Control
Automatic Fan Speed Mode
8.2. Soft Dry Mode Operation
  • The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and
then Soft Dry operation will start.
  • During Soft Dry operation, the Indoor Fan will operate at Lo- speed.
  • The operation will be switched on and off for up to 10 minutes “ON” and 6 minutes “OFF”. Once Soft Dry operation is turned
off, it stops for 6 minutes.
  • Once the compressor stops, it will not start for 3 minutes during Cooling operation.
  • Same as Starting Current Control for Cooling Mode operation.
  • Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor
stops.)
  • Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting
is valid during compressor stops.)
  • Same as Compressor Protection Control for Cooling Mode Operation.
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
  • Fan speed rotates at Lo- speed.
  • Deodorizing Control.
19
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
Soft Dry Operation Time Diagram
Quiet Operation Control
(For Dry region at Soft Dry Mode)
20
CS-A9CKPG CU-A9CKP6G / CS-A12CKPG CU-A12CKP6G
Page of 82
Display

Click on the first or last page to see other CS-A9CKPG / CU-A9CKP6G / CS-A12CKPG / CU-A12CKP6G (serv.man2) service manuals if exist.