JBL SPOT (serv.man3) EMC - CB Certificate ▷ View online
Page 47 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
NATIONAL DIFFERENCES OF Malaysia : IEC 60065, 7th Edition (CB Bulletin No. 110A, June 2006)
Energy Commission circular No. 1 year 2003(no. 1/2003)
States that a Certificate of Approval is required for manufacturing, selling, advertising,
displaying or importing into Malaysia, electrical/electronic products Listed in Annex A
displaying or importing into Malaysia, electrical/electronic products Listed in Annex A
-
- The supply voltage in Malaysia is 240Vac, at
50hz
50hz
Adaptor: 100-240Vac, 50/60Hz
N
- Class 0 and 01 appliances are not allowed
18 Vdc powered equipment
N
- 13A fused plug-tops shall comply to Malaysian
standard(MS 589:Part1: 1997), if applicable.
standard(MS 589:Part1: 1997), if applicable.
N
- 2-pin plug tops shall comply to Malaysian
standard (MS 1578:2003) if applicable.
standard (MS 1578:2003) if applicable.
N
Page 48 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
NATIONAL DIFFERENCES OF USA : IEC 60065, 7th Edition (CB Bulletin No. 110A, June 2006)
1.1.1 Scope
clarification:
The standard also covers commercial and
professional apparatus; professional apparatus
may also be investigated using UL 1419.
Projection apparatus is not covered. Household
games, household gaming and scoring machines,
satellite receiver antenna positioners are covered
by this standard but commercial games and
commercial gaming and scoring machines, and
other types of antenna positioners are covered by
other standard.
professional apparatus; professional apparatus
may also be investigated using UL 1419.
Projection apparatus is not covered. Household
games, household gaming and scoring machines,
satellite receiver antenna positioners are covered
by this standard but commercial games and
commercial gaming and scoring machines, and
other types of antenna positioners are covered by
other standard.
Add: Mains connected apparatus intended for field
installation requires compliance with the National
Electrical Code, ANSI, NFPA 70.
installation requires compliance with the National
Electrical Code, ANSI, NFPA 70.
N
1.1.3
Protection against splashing water replaced with
apparatus intended for outdoor use (See Annex
A).
apparatus intended for outdoor use (See Annex
A).
Not outdoor use.
N
1.1.5
Add: Some equipment covered by these
requirements may also be required to comply with
applicable requirements in other standards
requirements may also be required to comply with
applicable requirements in other standards
No special application
N
1.2
Add references to ANSI, ASTM and UL standards. Noted
N
4.2.1
Add Note: In the U.S. the RATED SUPPLY
VOLTAGE for single-phase apparatus is assumed
to be 120 V or 120/240 V.
VOLTAGE for single-phase apparatus is assumed
to be 120 V or 120/240 V.
18 Vdc powered equipment
N
4.2.4
Revision to sub-clause a): Minimum audio output is
not less than 0.5 W per channel unless the
maximum audio output is less than 0.5 W per
channel.
not less than 0.5 W per channel unless the
maximum audio output is less than 0.5 W per
channel.
0.5W applied for tests
P
4.2.4.1
Add: “An apparatus with multiple modes of
operation, multiple signal input sources, or both, is
to be operated using each mode of operation or
signal input source separately, or in combination,
according to the manufacturer’s instructions to
produce the maximum power input”.
operation, multiple signal input sources, or both, is
to be operated using each mode of operation or
signal input source separately, or in combination,
according to the manufacturer’s instructions to
produce the maximum power input”.
Table 2: External supply sources are assumed to
be capable of delivering 30 A, unless otherwise
specified (no-load voltage and internal resistance
values in the Table are modified).
be capable of delivering 30 A, unless otherwise
specified (no-load voltage and internal resistance
values in the Table are modified).
N
4.3.4
PTC thermistors may also comply with UL 1434.
No such component.
N
Page 49 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
5.1
Add: Component power supplies and adapters
complying with the construction and test
requirements of UL 1310, UL 1950, or UL 60950
fulfill the requirements of items “a” through “i” of
this clause.
complying with the construction and test
requirements of UL 1310, UL 1950, or UL 60950
fulfill the requirements of items “a” through “i” of
this clause.
N
5.1f
Add: Rated frequency is required on all apparatus. 18 Vdc powered equipment
N
5.1g
Add: Rated current or power required on all
apparatus.
apparatus.
18 Vdc, 2,5A
P
5.1j
Add: Date of Manufacture marking required on all
apparatus.
apparatus.
Marked P
5.1k
Add: Manufacturing identification marking required.
P
5.1l
Add: Combination of two graphical symbols and
supplementary marking is required.
supplementary marking is required.
N
5.1m
Add: Equipment rack marking required for
audio/video systems.
audio/video systems.
Not such equipment.
N
5.1n
Add: Units having leakage current levels greater
than 0.75 MIU and equal to or less than 3.5 MIU
must be marked with a high leakage current
marking.
than 0.75 MIU and equal to or less than 3.5 MIU
must be marked with a high leakage current
marking.
N
5.2c
Modification: Output terminals must be marked
with voltage, frequency and current or power;
output terminals installed or interconnected in the
field must be marked with the class of wiring.
with voltage, frequency and current or power;
output terminals installed or interconnected in the
field must be marked with the class of wiring.
N
5.2d
Add: Audio output connections shall be marked
“Class 1 Wiring”, “Class 2 Wiring” or “Class 3
Wiring”. Operation manual shall discuss risks and
proper connecting and insulation techniques when
connecting a speaker.
“Class 1 Wiring”, “Class 2 Wiring” or “Class 3
Wiring”. Operation manual shall discuss risks and
proper connecting and insulation techniques when
connecting a speaker.
< 10W audio output
N
5.3
Add: “An explanation and illustration of safety
related graphical symbols used on the apparatus
shall be included in the owner’s instructions
preceding any operating instructions.
related graphical symbols used on the apparatus
shall be included in the owner’s instructions
preceding any operating instructions.
N
5.4
Add: Important Safety Instructions are to be
packed with each apparatus and shall be verbatim.
packed with each apparatus and shall be verbatim.
P
5.4.1
Warning about Outdoor Use is required.
Not outdoor use.
N
5.4.3
Add: When apparatus contains instructions for use
by service personnel the instructions are separate
in format and preceded by a precautionary warning
statement.
by service personnel the instructions are separate
in format and preceded by a precautionary warning
statement.
18 V d.c. powered equipment
N
Page 50 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
6.1
Starting from second paragraph replace all
by:”Compliance is checked in accordance with the
requirements in the U.S. Code of Federal
Regulation, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3 and 1020.10 by
measuring the radiation produced by the
apparatus employing a design center chassis.”
by:”Compliance is checked in accordance with the
requirements in the U.S. Code of Federal
Regulation, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3 and 1020.10 by
measuring the radiation produced by the
apparatus employing a design center chassis.”
No radiation.
N
6.2
Starting from second paragraph replace all by:
“Apparatus shall be classified and labeled in
accordance with the Code of Federal Regulations,
Title 21, Chapter 1, Subchapter J, Sections
1010.2, 1010.3, 1040.10 and 1040.11.”
“Apparatus shall be classified and labeled in
accordance with the Code of Federal Regulations,
Title 21, Chapter 1, Subchapter J, Sections
1010.2, 1010.3, 1040.10 and 1040.11.”
N
6.2.2 Deleted
Table 3: Temperature limits added for various
classes of insulation systems.
classes of insulation systems.
Add to Note a): “Materials rated in accordance with
UL 746B may be used at their rated higher
temperature.”.7.2 – Add: A material temperature
rating can be accepted in lieu of the softening
temperature. The softening test need not be
performed on materials used in UL Listed or
Recognized parts.
UL 746B may be used at their rated higher
temperature.”.7.2 – Add: A material temperature
rating can be accepted in lieu of the softening
temperature. The softening test need not be
performed on materials used in UL Listed or
Recognized parts.
N
8.1
Add: “A metal part that is not inherently resistant to
corrosion shall be protected against corrosion
when corrosion of that part is capable of
contributing to or resulting in a risk of fire, shock, or
injury to persons.”
corrosion shall be protected against corrosion
when corrosion of that part is capable of
contributing to or resulting in a risk of fire, shock, or
injury to persons.”
No such part.
N
8.9.1
Add: “Sleeving, tape, tubing, and wire insulation
are suitable for the conditions of use, such as
voltage and temperature, and comply with UL 224,
UL 510, and UL 1441, as applicable.”
are suitable for the conditions of use, such as
voltage and temperature, and comply with UL 224,
UL 510, and UL 1441, as applicable.”
N
8.10
Add: “Component power supplies and their internal
insulation complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition,
or UL 60950 are considered to fulfill the test
requirements on the clause.”
insulation complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition,
or UL 60950 are considered to fulfill the test
requirements on the clause.”
N
8.12
Modification: Conductors and internal wiring
connecting mains socket-outlets shall comply with
the wire size requirements in clause 16.2 based on
the marked rating of the outlet but shall not be less
than 18 AWG.
connecting mains socket-outlets shall comply with
the wire size requirements in clause 16.2 based on
the marked rating of the outlet but shall not be less
than 18 AWG.
No such component.
N
8.17
As an option, winding wire insulation may comply
with the requirements in UL Subject 2353.
with the requirements in UL Subject 2353.
N
8.19.1
Modification: An all-pole switch or circuit breaker is
not required to have contact separation of 3 mm.
not required to have contact separation of 3 mm.
No switch.
N