JBL SPOT (serv.man3) EMC - CB Certificate ▷ View online

 
Page 39 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
9.1.1.2 
Determination of accessible parts 
Add the following after the fourth paragraph 
Moving parts of loudspeaker systems, such as 
dust caps, cones of drivers, or passive radiators, 
are not regarded as preventing accessibility. 
Note 1A: See also Clause 13.3.1 
 N 
9.2 
Removal of protective covers 
Add the following after the second paragraph 
This requirement applies also to internal parts of 
loudspeaker systems that become accessible by 
removal of a loudspeaker grille from the outside 
either by hand or with the use of a tool, coin, or 
other object. In such cases, the apparatus shall 
be marked according to Clause 5.3A. 
Replace the third paragraph with the following 
Compliance is checked by inspections and by 
application of the tests of Clause 9.1.1, except 
that the measurements are made 2 s after 
removal of the cover or grille.  
 N 
10 
Insulation requirements 
 
— 
10.2A 
Enclosure type designation and use 
Add the following paragraph 
If equipment is installed in environments where 
the enclosure is required to prevent ingress of 
water or dust, the enclosure shall be classified as 
a type recognized by the Canadian Electrical 
Code, Part I
, and shall comply with the 
requirements of CAN/CSA – C22.2 No. 94. 
 N 
11.2 
Heating 
Add the following paragraph 
Flammable gases shall not be emitted from a 
component for more than 10 s. 
No such gas. 
12 
Mechanical strength 
See below. 
— 
12.3A 
Television Impacts 
Add the following clause 
Not TV. 
 
Page 40 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
12.3A.1 
For television sets and similar apparatus using a 
cathode ray tube larger than 160 mm diagonally, 
the top, sides, front, and rear of the enclosure, 
including the safety screen where provided, shall 
be capable of withstanding a single impact of 7 J in 
accordance with Clause 12.3A.2 without 
developing any opening larger than 130 mm in the 
enclosure of the cathode ray tube, unless the 
minor dimension of 2 any opening is not more than 
7 mm. 
When applied to a safety screen, the impact shall 
not result in damage to its mounting to the extent 
that it is mechanically unsuitable for reuse, nor 
shall tempered glass, if used, be cracked. 
When applied to the face of a directly viewed 
cathode ray tube, the impact shall not cause any 
opening in the face of the tube. 
Scaling and cracking of the glass shall be 
permissible. A cathode ray tube that has been 
shown to comply with CAN/CSA – C22.2 No. 228 
or CAN/CSA – E 61965 shall be considered 
acceptable with no further tests. 
Not TV 
12.3A.2 
The impact specified in clause 12.3A.1 shall be 
caused by following a solid, smooth, steel sphere 
51mm in diameter and weighing approximately 
0.5kg to strike the enclosure with the specified 
impact in a direction perpendicular to the 
enclosure surface. If deemed necessary, the 
enclosure shall be tested with the proper cathode 
ray tube mounted. 
Not TV 
13.3 
Clearances 
 
— 
13.3.1 
General 
Add the following after the third paragraph 
Clearances between a loudspeaker voice coil 
and adjacent conductive parts shall be 
disregarded. 
 N 
14.2 
Capacitors and RC - units 
 
— 
14.2.1 
Add the following paragraph 
As an alternative, an isolating capacitor 
complying with applicable requirements of CSA 
C22.2 No. 1 shall be acceptable for bridging 
basic or supplementary insulation.  
 N 
 
Page 41 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
14.2.2 
Add the following paragraph 
As an alternative, a cross-line capacitor 
complying with applicable requirements of CSA 
C22.2 No. 1 shall be acceptable. 
 N 
14.5.1 
Thermal releases 
 
— 
14.5.1.2 
Add the following paragraph 
As an alternative, a thermal link complying with 
CSA C22.2 No. 209 shall be acceptable 
No thermal link 
14.5.2 
Fuse – links and fuse holders 
 
— 
14.5.2.1 
Add the following paragraph 
As an alternative, a fuse-link complying with CSA 
C22.2 No. 284.14 shall be acceptable. 
 N 
14.5.2.4 
Add the following paragraph 
As an alternative, a fuseholder assembly 
complying with CSA Standard C22.2 No. 39 shall 
be acceptable. 
No fuse holder 
14.6 
Switches  
 
— 
14.6.1 
Add the following paragraph 
As an alternative, a TV-rated switch complying 
with CSA C22.2 No. 1, Clause 9 shall be 
acceptable. 
No switch controls exceeding 
0,2A, 35 V peak a.c. or 24 V 
d.c. 
14.6.2 
Add the following paragraph 
As an alternative, a TV-rated switch complying 
with CSA C22.2 No. 1, Clause 9 shall be 
acceptable. 
 N 
14.6.3 
Add the following paragraph 
As an alternative, a TV-rated switch complying 
with CSA C22.2 No. 1, Clause 9 shall be 
acceptable. 
 N 
14.6.4 
Add the following paragraph 
As an alternative, a TV-rated switch complying 
with CSA C22.2 No. 1, Clause 9 shall be 
acceptable. 
 N 
14.6.5 
Add the following paragraph 
As an alternative, a TV-rated switch complying 
with CSA C22.2 No. 1, Clause 9 shall be 
acceptable. 
 N 
 
Page 42 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
14.11 
Optocouplers 
Add the following paragraph 
As an alternative, an optocoupler complying with 
CSA C22.2 No. 1 shall be acceptable. 
None N 
14.12 
Surge supperssion varistors  
Add the following paragraph 
As an alternative, a varistor complying with CSA 
C22.2 No. 1 shall be acceptable.  
No such varistor 
14.12A 
Gas discharge tubes 
Add the following clause 
Gas discharge tubes complying with following tests 
may be connected to bridge basic or reinforced 
insulation. Ten samples of gas discharge tubes 
isolating the ac supply from exposed parts shall be 
subjected to the varistor pulse tests of Clause 
14.12. 
Following the pulses, the device shall be allowed 
to return to room temperature. The dielectric 
breakdown voltage of the gas tube shall not 
decrease by more than 50%, and the gas 
discharge tube shall comply with the dielectric 
strength test of Clause 10.3, with the test voltage 
reduced to twice the mains voltage.  
No gas tube. 
15.1 
Plugs and sockets 
 
— 
15.1.1 
Add the following paragraph 
A receptacle provided for general purpose mains 
output shall comply with the requirements of CSA 
Standard C22.2 No. 42 (dimensional requirements 
are also specified in IEC 60906-2). The attachment 
plug cap shall be polarized type when the 
apparatus is provided with a manually operated, 
MAINS connected single pole switch for apparatus 
on-off operation, a socket screw shell lampholder, 
or a 15 or 20 ampere socket outlet. 
No socket outlet 
15.1.2 
Add the following paragraph 
Banana plugs shall be acceptable. 
No banana plugs 