DOWNLOAD JBL SPOT (serv.man3) Service Manual ↓ Size: 7.74 MB | Pages: 72 in PDF or view online for FREE

Model
SPOT (serv.man3)
Pages
72
Size
7.74 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
spot-sm3.pdf
Date

JBL SPOT (serv.man3) EMC - CB Certificate ▷ View online

 
Page 31 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
 
 
NATIONAL DIFFERENCES OF AUSTRALIA : IEC 60065, 7th Edition (CB Bulletin No. 110A, June 2006) 
 
ZZ.1 Introduction 
 
 
This Annex sets out variations between this Standard and IEC 60065:2001. 
These variations indicate national variations for purposes of the IECEE CB 
Scheme and will be published in the IECEE CB Bulletin. These variations are 
indicated within the body of the Standard by shading and strikethrough.  
 
ZZ.2 
Variations 
 
 
The variations are as follows: 
 
7.1.5 
In Table 3 under item c) add an h) in both columns 
against 'thermoplastic materials' and add the 
following new footnote: 
h  As an alternative to the method described in 
footnote f) the following variation may be used 
where there is any doubt about the suitability of 
the material:  
The ball-pressure test described in AS/NZS 
60695.10.2 may be carried out.  
To assess compliance under normal operating 
conditions, the test shall be made in a heating 
cabinet at a temperature of 40°C ± 2°C plus the 
maximum temperature rise determined under 
normal operating conditions but, it shall be at 
least;  
-       for external parts 75°C ± 2°C 
-      for material supporting parts conductively 
connected to the mains  125°C ± 2°C. 
 N 
7.2 
After the second paragraph, add the following: 
The alternative method described in footnote h) of 
Table 3 may be used. 
 N 
15.1.1 
After the second paragraph, add the following:  
 
 
Plugs for the connection of apparatus to mains-
powered socket-outlets shall comply with AS/NZS 
3112 or AS/NZS 3123. Apparatus with a plug 
portion, suitable for insertion into a 10 A 3-pin flat-
pin socket-outlet complying with AS/NZS 3112, 
shall comply with the requirements of AS/NZS 
3112 for equipment with integral pins for insertion 
into socket-outlets. 
18 Vdc powered equipment 
15.3.5 
In Table 15, in the second and third rows of the 
first column replace ‘6’ with ‘7.5’. 
 
 
Page 32 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
16.2 
In Table 18, in the second and third rows of the 
first column replace ‘6’ with ‘7.5’. 
 
16.3 
In item (b), add the following:  
 
 
A flexible cord complying with AS/NZS 3191 need 
not undergo this test. 
 N 
20 
Add the following after NOTE 2:  
 
 
For alternative test refer to Clause 20.201. 
 
20.1.4 
In Table 21, in the third and fourth columns 
change both ‘HB75’ and ‘No requirement’ to ‘V-1’.  
No potential ignition sources 
20.2.3 
After this Clause, add the following variation: 
 
 
20.201 
Resistance to fire-Alternative tests 
 
 N 
20.201.1 General 
Parts of non-metallic material shall be resistant to 
ignition and the spread of fire.  
This requirement does not apply to decorative 
trims, knobs and other parts unlikely to be ignited 
or to propagate flames originating from inside the 
apparatus, or the following: 
 N 
 
(a) Components that are contained in an 
enclosure having a flammability category of V-O 
according to AS/NZS 60695.11.10 and having 
openings only for the connecting wires filling the 
openings completely, and for ventilation not 
exceeding 1 mm in width regardless of length. 
 N 
 
(b) The following parts which would contribute 
negligible fuel to a fire: 
- small mechanical parts, the mass of which does 
not exceed 4 g, such as mounting parts, gears, 
cams, belts and bearings; 
- small electrical components, such as capacitors 
with a volume not exceeding 1 750 mm
3
integrated circuits, transistors and optocoupler 
packages, if these components are mounted on 
material of flammability category V-1 or better 
according to AS/NZS 60695.11.10. 
NOTE - In considering how to minimize 
propagation of fire and what 'small parts' are, 
account should be taken of the cumulative effect 
of small parts adjacent to each other for the 
possible effect of propagating fire from one part 
to another. 
 N 
 
Page 33 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
 
Compliance shall be checked by the tests of 
20.201.2.1, 20.201.2.2. and 20.201.2.3 
 N 
 
For the base material of printed boards, 
compliance shall be checked by the test of 
20.201.2.4.  
 N 
 
The tests shall be carried out on parts of non-
metallic material which have been removed from 
the apparatus. When the glow-wire test is carried 
out, they are placed in the same orientation as 
they would be in normal use. 
These tests are not carried out on internal wiring.
 N 
20.201.2 Tests 
 
20.201.2.1  Testing of non-metallic parts 
 
 
Parts of non-metallic material shall be subject to 
the glow-wire test of AS/NZS 60695.2.11 which 
shall be carried out at 550
o
C. 
 N 
 
Parts for which the glow-wire test cannot be 
carried out, such as those made of soft or foamy 
material, shall meet the requirements specified in 
ISO 9772 for category FH-3 material. The glow-
wire test shall not be carried out on parts of 
material classified at least FH-3 according to ISO 
9772 provided that the sample tested was not 
thicker than the relevant part. 
 N 
20.201.2.2  Testing of insulated parts 
Part of insulating material supporting potential 
ignition sources shall be subject to the glow-wire 
test of AS/NZS 64695.2.11 which shall be carried 
out at 750
o
C. 
 N 
 
The test shall be also carried out on other parts of 
insulating material which are within a distance of 
3 mm of the connection 
NOTE - Contacts in components such as switch 
contacts are considered to be connections. 
 N 
 
For parts which withstand the glow-wire test but 
produce a flame, other parts above the 
connection within the envelope of a vertical 
cylinder having a diameter of 20 mm and a height 
of 50 mm shall be subjected to the needle-flame 
test. However, parts shielded by a barrier which 
meets the needle-flame test need not be tested. 
 N 
 
The needle-flame test shall be made in 
accordance with AS/NZS 4695.2.2 with the 
following modifications: 
 N 
 
 
Page 34 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
 
 
5 Severities 
 
 
Replace with:  
 
 
The duration of application of the test flame shall 
be 30 s ± 1 s. 
 Noted 
8 Test 
procedure 
 
8.2 
Replace the first sentence with: 
 
 
The specimen shall be arranged so that the flame 
can be applied to a vertical or horizontal edge as 
shown in the examples of figure 1. 
 Noted 
8.4 
The first paragraph does not apply. 
 
Noted 
 . 
Addition: 
 
 
If possible, the flame shall be applied at least 10 
mm from a corner. 
 Noted 
8.5 
Replace with:  
 
 
The test shall be made on one specimen. If the 
specimen does not withstand the test, the test 
may be repeated on two further specimens, both 
of which shall then withstand the test. 
 Noted 
10 
Evaluation of test results 
 
 
Replace with: 
 
 
The duration of burning (tb) shall not exceed 30 
s. However, for printed circuit boards, it shall not 
exceed 15 s. 
 Noted 
 
The needle-flame test shall not be carried out on 
parts of material classified as V-0 or V-1 
according to AS/NZS 60695.11.10 provided that 
the sample tested was not thicker than the 
relevant part. 
 N 
20.201.2.3  Testing by needle-flame test 
If parts, other than enclosures, do not withstand 
the glow wire tests of 20.201.2.2, by failure to 
extinguish within 30 s after the removal of the 
glow-wire tip, the needle-flame test detailed in 
20.201.2.2 shall be made on all parts of non-
metallic material which are within a distance of 50 
mm or which are likely to be impinged upon by 
flame during the tests of 20.201.2.2. Parts 
shielded by a separate barrier which meets the 
needle-flame test shall not be tested. 
 N 
Page of 72