JBL SPOT (serv.man3) EMC - CB Certificate ▷ View online
Page 27 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
14
TABLE: list of critical components and materials
P
Object / part No.
manufacturer /
trademark
trademark
Type / model
technical data
standard
mark(s) of
conformity
conformity
1
)
Power Adaptor
Kuantech
(Shenzhen)
(Shenzhen)
KSAFH1800250T
1M2
1M2
Input: 100-240Vac,
50/60Hz, 1,2A;
Output: 18Vdc, 2,5A
IEC60065
2001
2001
TUV Product
Service, CB
(DE 3 –
81920)
Service, CB
(DE 3 –
81920)
PCB Material
Various
Various
V-1or better,
minimum 105
°C
UL 94
UL
Plastic Enclosure Various
Various
Rated HB or better
UL 94, UL
746C.
746C.
UL
Speaker
(two provided)
(two provided)
Various Various 4
Ω, 3 W
-- --
Subwoofer
Speaker
Speaker
Various Various 5
Ω, 30 W
-- --
1
) an asterisk indicates a mark which assures the agreed level of surveillance
Page 28 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
ZB
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
N
2.6.1
DK: certain types of Class I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
N
13.3.1
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
N
15.1.1
DK: mains cord for single-phase equipment having
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
N
DK: Class I equipment with socket-outlets with
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
N
DK: socket-outlets for providing power to Class II
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
No socket-outlets
N
DK: mains socket-outlets with earthing contact
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
No socket-outlets
N
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
N
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
N
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
following amendments:
N
- dimensions 2,5 A, 250 V socket-outlets shall
comply with Standard Sheet 1 page 132 of
EN 60 065:98
comply with Standard Sheet 1 page 132 of
EN 60 065:98
No socket-outlets
N
- mechanical strength 2,5 A, 250 V socket-outlets
tested as specified in EN 60 065, 12.1.3
tested as specified in EN 60 065, 12.1.3
N
- protecting rim also tested
N
Page 29 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
No TNV.
N
J.2
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
N
ZC
ANNEX ZC TO EN 60 065, A-DEVIATIONS
N
5
DE: additional markings required in German language:
N
- cathode ray tubes with an accelerating voltage
between 20 kV and 30 kV (marking on the tube)
between 20 kV and 30 kV (marking on the tube)
No tube
N
- TV receivers whose picture tube has an
accelerating voltage between 20 kV and 30 kV
accelerating voltage between 20 kV and 30 kV
N
- TV receivers whose picture tube has an
accelerating voltage greater than 30 kV
accelerating voltage greater than 30 kV
N
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
accelerating voltage less than 20 kV
N
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N
IT: user instructions in Italian language including a
conformity declaration
conformity declaration
N
IT: certification number on the back cover
N
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
No such components used.
N
Page 30 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
NATIONAL DIFFERENCES OF ARGENTINA : IEC 60065, 7th Edition (CB Bulletin No. 110A, June 2006)
Ratings shall cover 220 Vac - 50 Hz
18 Vdc powered equipment N
Class 0 and Class 0I appliances are not allowed
N
Safety instructions and manuals shall be written in
Spanish language (Resolution 92/98)
Spanish language (Resolution 92/98)
It shall be provided when it is
marketed for Argentina.
marketed for Argentina.
N
Country of origin shall be shown on the marking
plate or, if not possible, in the primary packaging
(Resolution 92/98)
plate or, if not possible, in the primary packaging
(Resolution 92/98)
Marked N
Address of the importer in Argentina shall be
shown on the product or on the primary packaging
(Resolution 92/98)
shown on the product or on the primary packaging
(Resolution 92/98)
It shall be provided when it is
marketed for Argentina.
marketed for Argentina.
N
Class I appliances provided with plugs shall be
provided with the label specified in sheet "Class I"
(Disposition 731/87)
provided with the label specified in sheet "Class I"
(Disposition 731/87)
N
Class II appliances provided with plugs shall be
provided with the label specified in sheet "Class II"
(Disposition 731/87)
provided with the label specified in sheet "Class II"
(Disposition 731/87)
N
Plugs shall be in conformity with IRAM 2063
Standard for Class II appliances and IRAM 2073
Standard for Class I appliances (Resolution
524/98)
Standard for Class II appliances and IRAM 2073
Standard for Class I appliances (Resolution
524/98)
N
Adaptors/Transformers
provided with integrated
plugs shall be provided with blades which shall
meet the geometry of IRAM 2063 standard
forClass II appliances or IRAM 2073 standard for
Class I appliances (Resolution 524/98)
meet the geometry of IRAM 2063 standard
forClass II appliances or IRAM 2073 standard for
Class I appliances (Resolution 524/98)
No such equipment
N
Appliances certified under System Nº 4 (Type
Certification scheme) shall be marked with the
symbol specified in sheet "St Mark" (Resolution
197/04)
Certification scheme) shall be marked with the
symbol specified in sheet "St Mark" (Resolution
197/04)
It shall be provided when it is
marketed for Argentina.
marketed for Argentina.
N
Appliances certified under System Nº5 (Mark of
Conformity Certification scheme) shall be marked
with the symbols specified in sheet "S Mark"
(Resolution 799/99)
Conformity Certification scheme) shall be marked
with the symbols specified in sheet "S Mark"
(Resolution 799/99)
N