Page 43 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
15.1.3 
Add the following title 
Adapter output connectors 
Replace the first paragraph with the following 
Terminals and connectors used in output circuits of 
supply apparatus, whose output voltage is not a 
standard nominal mains voltage according to IEC 
60038 (1), IEC 60320, IEC 60884, IEC 60906 
(parts 1, 2, and 3), and CSA C22.2 No. 42.  
 N 
15.2 
Provisions for protective earthing 
Replace the first paragraph with the following 
Earthing connections shall comply with the test 
requirements of CSA C22.2 No. 0.4. 
 N 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
 
— 
15.3.1A 
Add the following clause 
Equipment intended for permanent connection to 
the mains shall have provisions for connection to 
the wiring system in accordance with the Canadian 
Electrical Code, Part I. 
The terminal parts and all other provisions for 
permanent connection to fixed wiring shall comply 
with CSA Standard CAN/CSA-C22.2 No. 0. 
Not such equipment. 
15.4 
Devices forming a part of the mains plug 
 
— 
15.4.2 
Add the following paragraphs 
Mains plugs of non-permanently installed 
equipment shall comply with 
a) CSA C22.2 No. 21 for moulded-on type 
attachment plugs; and 
b) CSA C22.2 No. 42 for disassembly type 
attachment plugs (dimensional requirements are 
also specified in IEC 60906-2). 
Class II equipment provided with a general 
purpose mains outlet, or lampholder, shall be 
provided with a polarized-type plug.  
If the plug is a polarized type, single pole switches 
or over current protectors shall not be connected in 
the identified conductor. 
 N 
16 
External flexible cords 
 
— 
 
Page 44 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
16.1 
Replace this clause with the following 
Flexible cord used for mains supply shall comply 
with the requirements of CSA C22.2 No. 49. The 
cord type shall be in accordance with Table 4 of 
CSA C22.2 No. 1. 
The attachment plug shall be rated not less than 
125% of the apparatus rated current. 
Cord sets shall comply with the requirements of 
CSA C22.2 No. 21. 
Non-detachable flexible cables and cords of Class 
I apparatus shall be provided with a green/yellow 
core connected to the protective earthing terminal 
of the apparatus and, if a plug is provided , to the 
protective earthing contact of the plug. 
Compliance is checked by inspection. 
Note: The colour for cores of flexible mains cords is contained in 
IEC 60173 (4). 
No such cord. 
17 
Electrical connections and mechanical fixings   
— 
17.9A 
Adhesive securement and conductive coatings
Add the following clause 
No such part. 
17.9A.1 
Adhesive securement 
The following parts, the displacement of which may 
result in a fire or shock hazard, shall not be 
secured solely by adhesive, unless the adhesive 
system complies with the resistance to external 
forces test of Clause 9.1.7, the bump test of 
Clause 12.1.1, and the impact test of Clause 
12.1.3, after conditioning in accordance with 
Clause 17.9A.2: 
a) internal metal parts/conductive coatings; 
b) barriers; and 
c) required enclosure parts. 
Note: Cathode ray tubes are excluded from this test. 
 N 
17.9A.2 
Adhesive and conductive coating securement 
conditioning 
 
— 
17.9A.2.1 
General 
Where required by Clause 17.9A.1, one sample of 
the apparatus or enclosure section shall be 
conditioned in accordance with the requirements of 
Clause 17.9A.2.2. Equivalent ageing test data 
supplied by the manufacturer will be considered in 
lieu of ageing. 
 N 
 
Page 45 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
17.9A.2.2 
Ageing 
Day 1: Place in oven at 100
±
1°C for 1 week, or 82
±
1°C for 8 weeks at the manufacturer’s option. 
Day 8 or Day 57: 
1.  Remove from oven and leave at room 
temperature for 1h. 
2.  Place in freezer at –35°C for 2h. 
3.  Remove from freezer and allow to reach room 
temperature overnight. 
Day 9 or Day 58: 
1.  Place in a compartment at 96% relative 
humidity for 3h. 
2.  Remove and leave at room temperature and 
humidity for 1h. 
3.  Place in oven at a temperature selected in the 
first cycle for 3h. 
4.  Remove and allow to come to room 
temperature overnight. 
Day 10 or Day 59: 
1.  Place in Freezer at –35°C for 2h. 
2.  Remove and leave at room temperature for 
1h. 
3.  Place in humidity chamber at 96% relative 
humidity for 3h. 
4.  Remove and allow to come to room 
temperature overnight. 
Day 11 or Day 60: 
1.  Place in oven at a temperature selected in the 
first cycle for 3h. 
2.  Remove for 1h. 
3.  Place in Freezer at –35°C for 2h. 
4.  Remove and allow to come to room 
temperature overnight. 
Day 12 or Day 61: 
1.  Place in humidity chamber at 96% relative 
humidity for 3h. 
2.  Remove and perform mechanical tests as 
required by Clause 17.10.1 or 17.10.2 as 
applicable. 
 N 
 
Page 46 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
18 
Mechanical strength of picture tubes and 
protection against the effects of implosion 
 
— 
18.1A 
Add the following clause 
A picture tube with a maximum face dimension 
exceeding 75mm either shall be intrinsically 
protected with respect to effects of implosion and 
to mechanical impact in accordance with 
CAN/CSA - C22.2 No. 228 or CAN/CSA – E61965, 
or the enclosure of the apparatus shall provide 
adequate protection against the effects of an 
implosion of the tube (see Clause 12) 
No such tube. 
19 
Stability and mechanical hazards 
Add the following after the second paragraph 
The test of Clause 19.3 is only required for 
a) 
apparatus with a mass of 25kg or more
b) 
apparatus, excluding loudspeaker 
systems, with a height of 1m or more, or 
c) 
apparatus, including loudspeaker 
systems, in combination with a supplied or 
recommended cart of stand with a total height 
of 1m or more. 
Add the following paragraph 
Apparatus not tested because it is intended to be 
fastened in place shall be provided with the 
following warning: 
“WARNING: This apparatus must be securely 
attached to the floor/wall per installation instruction. 
Tipping, shaking or rocking the machine may 
cause injury/death.” 
 N 
20.2 
Fire enclosure 
 
— 
20.2.1A 
Add the following clause 
Enclosures of apparatus containing high voltage or 
projection lamps shall have a minimum 
flammability rating of category FV1 according to 
IEC 60707 at the minimum thickness used. 
No such parts 
Annex B 
(normative) 
Apparatus to be connected to the 
telecommunication networks 
Replace this annex with the following 
Apparatus intended for direct connection to a 
telecommunication network shall comply with 
a)  Clasue 19 of CSA C22.2 No.1; or 
b)  CAN/CSA – C22.2 No. 60950. 
No TNV. 