DOWNLOAD JBL SPOT (serv.man3) Service Manual ↓ Size: 7.74 MB | Pages: 72 in PDF or view online for FREE

Model
SPOT (serv.man3)
Pages
72
Size
7.74 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
spot-sm3.pdf
Date

JBL SPOT (serv.man3) EMC - CB Certificate ▷ View online

 
Page 59 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
 
Modifications to figures: 
Fig 14 – Illustrates the articulated finger probe. 
Fig 15 – Illustrates the shock hazard marking and 
associated graphical symbols. 
Fig 16 – Illustrates the shock hazard graphical 
symbol. 
Fig 17 – Illustrates the portable cart marking. 
Fig 18 – High voltage spacings graph. 
Fig 19 – Class 105 insulation aging temperature 
graph. 
Fig 20 – Flowchart for horizontal force test. 
 N 
 
 
Page 60 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
 
 
Annex A 
Modification: Apparatus intended for outdoor use 
or wet locations has any of the following attributes: 
a) provided with a means to make it transportable, 
b) has a mass less than 35kg, c) can be battery 
operated, d) associated literature states or implies 
such use 
Add: Apparatus in a), b), or c) above is not 
considered for outdoor use or in wet locations if 
marked as specified in 5.4..A.5, A.5.4.1 are 
deleted. 
A9.1.1 – Add: Touch current test shall be 
conducted after the water spray test described in 
A.11.1.1 and the touch current shall not be more 
than 0.5MIU when the open-circuit potential 
between any accessible part and earth or any 
other accessible part is more than 21.2V peak. 
A.10, A10.2, A10.2.1, and A.10.2.2 are deleted. 
A.11.1.1 – Add: Apparatus shall be subjected to 
the water spray test according to UL 1571. 
A.16.1 – Add: Flexible cords shall be suitable for 
out door use. 
A.20.2.1 – Add: Enclosures for an apparatus 
intended for permanent outdoor location shall 
comply with requirements for Type 3 enclosures in 
UL 50. 
Not such equipment. 
 
Page 61 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
Annex B 
5th paragraph – add reference to clause 4.2.1.1 in 
IEC 62151. 
Add to 12th paragraph. “The requirements of 
4.2.1.1 shall be replaced by the requirements or 
2.3.1 of UL 60950, Third Edition.” 
13th paragraph, 2nd dash replace with: “In the 
event of a single insulation fault, the voltages on 
the TNV-0 circuits, TNV-1 circuits and accessible 
conductive parts shall not exceed the values given 
in clause 9.1.1.1a of this standard for more than 
0.2s. Moreover, the limits values as given in 11.1 
shall not be exceeded. After 0.2s the voltage limits 
of 4.1.2 (35 V peak, or 60 V d.c.) shall apply.” 
Add to 19th paragraph: “Apparatus intended to be 
connected to telecommunication networks and 
having ringing voltages applied to the apparatus 
ids subjected to touch current limits in accordance 
with clause 5.1.8.1.1 of UL 60950, Third 
Edition“ Add to 21st 
paragraph: ”Telecommunication network that uses 
outside cable shall comply with the requirements 
for protection against overvoltage from power line 
crosses per 6.4 of UL 60950, Third Edition” 
Add to 22nd paragraph: “Acoustic tests per 6.5 of 
UL 60950, Third Edition for apparatus containing 
earphone held against the ear.” 
Add to 24th paragraph: “Apparatus shall be 
provided with appropriate markings and 
instructions as described in Annex NAA of UL 
60950, Third Edition.” 
No TNV. 
Annex D 
Figure D.1 & Note delete reference to IEC 60990 
and add reference to ANSI C101. Add touch 
current value in MIU where MIU=U2x2 (r.m.s. 
value) 
 N 
Annex G 
Deleted 
 
Annex Q 
Add: Safety requirements for video apparatus for 
use in health care facilities 
Not such apparatus. 
Annex R 
Add: Safety requirements founder cabinet 
apparatus 
Not such apparatus. 
Annex S 
Add: Safety requirements for in-wall mounted 
apparatus 
Not such apparatus. 
Annex T 
Add: Safety requirements for apparatus with 
projection lamps 
Not such apparatus. 
Annex U 
Add: Safety requirements for permanently 
connected apparatus 
Not such apparatus. 
 
Page 62 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
Annex V 
Add: Safety requirements for carts, stands, and 
sillier apparatus for use with specific apparatus 
covered by this standard 
Not such apparatus. 
Annex W 
Add: Construction details for a 0.02-ohm shunt for 
use in the peak inrush-current measurement 
described in 14.6.11.1 
No such concern. 
Annex X 
Add: Manufacturing and production-line tests 
Added. 
Annex Y 
Add: Normative standards for components. 
Added. 
 
Page of 72