Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
15.1.3.1
Add: “An audio amplifier having an open-circuit
audio output voltage not limited to 120V that is
permanently connected to the mains shall be
provided with a means for connection complying
with U.21.1.1-U.21.1.7 and wire-binding screws
No. 6-32 or larger complying with U.21.3.1-
U.21.3.5, or quick-connect terminals, or leads.
Quick Connect Terminal shall comply with the
following: a) Male tabs firmly mounted in place, b)
Mating female connectors shall be provided with
the apparatus, c) Strain Relief Test of Clause 16.5,
d) Installation instructions shall be provided for
assembly of terminal to a conductor and strain
relief, e) Terminals shall be appropriate for use
with the size and type of wire specified.”
audio output voltage not limited to 120V that is
permanently connected to the mains shall be
provided with a means for connection complying
with U.21.1.1-U.21.1.7 and wire-binding screws
No. 6-32 or larger complying with U.21.3.1-
U.21.3.5, or quick-connect terminals, or leads.
Quick Connect Terminal shall comply with the
following: a) Male tabs firmly mounted in place, b)
Mating female connectors shall be provided with
the apparatus, c) Strain Relief Test of Clause 16.5,
d) Installation instructions shall be provided for
assembly of terminal to a conductor and strain
relief, e) Terminals shall be appropriate for use
with the size and type of wire specified.”
Not such equipment.
N
15.1.3.2
Add: “Audio amplifiers having an audio output not
limited to 120V that are connected to the mains by
a flexible cord shall have suitable cord or provision
for field installation or a receptacle for plug-in
connections,”
limited to 120V that are connected to the mains by
a flexible cord shall have suitable cord or provision
for field installation or a receptacle for plug-in
connections,”
N
15.2
Add after 3rd paragraph: “The earthing conductor
in a supply cord, or in an interconnecting cable
shall have an equivalent or large cross-sectional
area that the current-carrying conductors in the
supply cord or cable. With reference to earthing
conductors, the insulation color may be green or
green/yellow.
in a supply cord, or in an interconnecting cable
shall have an equivalent or large cross-sectional
area that the current-carrying conductors in the
supply cord or cable. With reference to earthing
conductors, the insulation color may be green or
green/yellow.
N
15.3.5
Revise 2nd paragraph to read: “For rated currents
exceeding 13A, reference is made to Article 310 of
the National Electrical Code, ANSI/NFPA 70.”
Table 15 – Replace with: “Normal cross-sectional
area AWG” and modify values.
exceeding 13A, reference is made to Article 310 of
the National Electrical Code, ANSI/NFPA 70.”
Table 15 – Replace with: “Normal cross-sectional
area AWG” and modify values.
Not such equipment.
N
15.4
Add: “Component power supply adaptors
complying with the construction and test
requirements on the clause.”
complying with the construction and test
requirements on the clause.”
N
16.1
Modification: Mains supply flexible cords shall
comply with UL 817, be marked VW-1, and have
an ampacity not less than the current drawn by the
apparatus. Delete reference to IEC 60227, 60245
and 60173.
comply with UL 817, be marked VW-1, and have
an ampacity not less than the current drawn by the
apparatus. Delete reference to IEC 60227, 60245
and 60173.
Table 17A – Add: Types of cords and lengths for
various types of apparatus.
various types of apparatus.
N
Page 56 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
16.2
An integral earthing conductor shall be at least the
same size as the other cord conductors. Substitute
“IEC 60950, table 3B” with Article 400 of the
National Electrical Code”.
same size as the other cord conductors. Substitute
“IEC 60950, table 3B” with Article 400 of the
National Electrical Code”.
Table 18 – Replace with “Wire sizes of external
flexible cords” Upper current limit in column 1
increased from 16 to 30A and “AWG” wire sizes
added.
flexible cords” Upper current limit in column 1
increased from 16 to 30A and “AWG” wire sizes
added.
N
16.3
Add: c) Flexible cords not complying with 16.1,
used as connection between the apparatus and
other apparatus used in combination with it, shall
be marked VW-1.
used as connection between the apparatus and
other apparatus used in combination with it, shall
be marked VW-1.
N
17.8
Expanded to include all cart/stand parts supplied
by the manufacturer, such as casters and
brackets. Suitable assembly instructions required.
Add: “Relevant fixing means are not required when
installation is to be done by a skilled person.”
by the manufacturer, such as casters and
brackets. Suitable assembly instructions required.
Add: “Relevant fixing means are not required when
installation is to be done by a skilled person.”
N
17.10
Add: Aluminum conductors used as internal wiring
shall be terminated by a method capable of being
used in the combination of metals involved at the
connection point.
shall be terminated by a method capable of being
used in the combination of metals involved at the
connection point.
No such conductor.
N
17.11
Add: An accessory shall be investigated to
determine that: a) The accessory, and the
combination of the accessory and the apparatus
shall present no hazard in the sense of this
standard and b) The accessory is provided with
installation instructions.
determine that: a) The accessory, and the
combination of the accessory and the apparatus
shall present no hazard in the sense of this
standard and b) The accessory is provided with
installation instructions.
No other accessory.
N
17.11.1
Add: The installation of an accessory of a killed
person shall be such that: a) The mechanical
positioning is accomplished by means of tools
normally available or by means of special tools
provided by the organization responsible for
providing the apparatus as part of the installation
kit, and b) The electrical connections are made by
using existing terminals and connections in the
apparatus or the building wiring.
person shall be such that: a) The mechanical
positioning is accomplished by means of tools
normally available or by means of special tools
provided by the organization responsible for
providing the apparatus as part of the installation
kit, and b) The electrical connections are made by
using existing terminals and connections in the
apparatus or the building wiring.
N
18
Modification: Non-intrinsically protected picture
tubes shall comply with 18.1, 18.2.2 and 18.3.
Intrinsically protected picture tubes shall comply
with UL 1418 or UL 61965.
tubes shall comply with 18.1, 18.2.2 and 18.3.
Intrinsically protected picture tubes shall comply
with UL 1418 or UL 61965.
Add: “A bulb of a picture tube having a face
diameter of 7.5cm or more shall be mounted in an
enclosure. The enclosure shall have no opening
that exceeds 130 mm
diameter of 7.5cm or more shall be mounted in an
enclosure. The enclosure shall have no opening
that exceeds 130 mm
2
unless the minor dimension
of the opening is 10 mm or less.”
No such tube.
N
Page 57 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
18.1
All tubes shall be mounted such that the enclosure
of the apparatus protects the tube against the
effects of implosion. Delete reference to clause
18.2.
of the apparatus protects the tube against the
effects of implosion. Delete reference to clause
18.2.
18.2, 18.2.1, and 18.2.3 are deleted..19-Add
reference to 19.2.1. The test of 19.3 is conducted
on 1) apparatus with direct view CRT with 48cm
reference to 19.2.1. The test of 19.3 is conducted
on 1) apparatus with direct view CRT with 48cm
diagonal min., 2) apparatus, other than a speaker,
with a mass greater than 47kg, and 3) apparatus,
other than a speaker, with a mass or 25kg or
greater and height of 1 m or more. The tests in
19.1, 19.2 and 19.3 shall not cause the apparatus
to overturn. During the test of 19.2.1, the
apparatus shall not slide.
with a mass greater than 47kg, and 3) apparatus,
other than a speaker, with a mass or 25kg or
greater and height of 1 m or more. The tests in
19.1, 19.2 and 19.3 shall not cause the apparatus
to overturn. During the test of 19.2.1, the
apparatus shall not slide.
N
19.2.1
Add: Slide test requirements.
Not such equipment.
N
19.3
Replace by Horizontal force stability test
requirements.
requirements.
Add: table 20A – Values for horizontal force test
N
19.6
Add: “or equipment rack mounting”.
N
20.1a Delete
N
20.1b
Replace “IEC 60707” with “UL 94”
Add: “-parts such as protection TV lenses,
loudspeaker parts, external accessories, and
fibrous materials less than 0.25mm thick.”
loudspeaker parts, external accessories, and
fibrous materials less than 0.25mm thick.”
N
20.1.2
Revise text to read: “Sleeving, extruded tubing and
insulation on wiring shall be rated VW-1 under
following conditions: a) wiring located in a circuit
that is considered a potential ignition source” or b)
wiring not located in a circuit that is a potential
ignition source but is in contact with wiring located
in a circuit that is a potential ignition source. “Tape
should be flame retardant.”
insulation on wiring shall be rated VW-1 under
following conditions: a) wiring located in a circuit
that is considered a potential ignition source” or b)
wiring not located in a circuit that is a potential
ignition source but is in contact with wiring located
in a circuit that is a potential ignition source. “Tape
should be flame retardant.”
Delete Note and add: “Tape in contact with parts of
circuits that are potential ignition source shall be
flame retardant.”
circuits that are potential ignition source shall be
flame retardant.”
N
Page 58 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
20.1.3
Replace 1st paragraph with: “Base material of
printed wiring boards, or which the available power
as the connection exceeds 15W or the operating
voltage exceeds 50V a.c. or d.c. under normal
operating conditions, shall be of flammability
category V-1 or better according to UL 94.”
printed wiring boards, or which the available power
as the connection exceeds 15W or the operating
voltage exceeds 50V a.c. or d.c. under normal
operating conditions, shall be of flammability
category V-1 or better according to UL 94.”
In 2nd paragraph replace “IEC 60707” with “UL 94”
and remove exception for printed boards housed in
metal enclosures.
and remove exception for printed boards housed in
metal enclosures.
In 3rd paragraph replace “IEC 60707” with “UL 94”
and delete option to use Clause G.1 of Annex G.
and delete option to use Clause G.1 of Annex G.
PCB: Min. V-1
N
20.1.4
Replace with: components and parts shall comply
with the relevant flammability category according
to UL 94 as specified in Table 21. Delete all other
text.
with the relevant flammability category according
to UL 94 as specified in Table 21. Delete all other
text.
N
20.1.4
Add: “Component power supplies complying with
the construction and test requirements of UL 1310,
UL 1950 Third Edition, or UL 60950 are
considered to fulfill the test requirements on the
clause.”
the construction and test requirements of UL 1310,
UL 1950 Third Edition, or UL 60950 are
considered to fulfill the test requirements on the
clause.”
Table 21 – Replace complete table with new table
for “Flammability categories for components and
parts.”
for “Flammability categories for components and
parts.”
N
20.2.1
Modification: 1st paragraph: “Fire enclosure
required for 1) circuits and components where the
available power exceeds 15W, 2) inductors and
windings conductively connected to the mains and
3) high-voltage products. The fire enclosure shall
comply with the flammability requirements of Table
22 according to UL 94 and 746C. 2nd, 3rd, and 4th
paragraphs are deleted.
required for 1) circuits and components where the
available power exceeds 15W, 2) inductors and
windings conductively connected to the mains and
3) high-voltage products. The fire enclosure shall
comply with the flammability requirements of Table
22 according to UL 94 and 746C. 2nd, 3rd, and 4th
paragraphs are deleted.
In 5th paragraph replace “IEC 60707 or clause G.1
of Annex G” with “UL 94 or UL 746C.”
of Annex G” with “UL 94 or UL 746C.”
Table 22 – Add “Flammability categories for fire
enclosures.”
enclosures.”
N
20.2.2
N
20.2.3
Modification: Outer enclosures shall have a
minimum flammability rating of HB, per UL 94,
when an internal fire enclosure is provided.
minimum flammability rating of HB, per UL 94,
when an internal fire enclosure is provided.
N