JBL SPOT (serv.man3) EMC - CB Certificate ▷ View online

 
Page 55 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
15.1.3.1 
Add: “An audio amplifier having an open-circuit 
audio output voltage not limited to 120V that is 
permanently connected to the mains shall be 
provided with a means for connection complying 
with U.21.1.1-U.21.1.7 and wire-binding screws 
No. 6-32 or larger complying with U.21.3.1-
U.21.3.5, or quick-connect terminals, or leads. 
Quick Connect Terminal shall comply with the 
following: a) Male tabs firmly mounted in place, b) 
Mating female connectors shall be provided with 
the apparatus, c) Strain Relief Test of Clause 16.5, 
d) Installation instructions shall be provided for 
assembly of terminal to a conductor and strain 
relief, e) Terminals shall be appropriate for use 
with the size and type of wire specified.” 
Not such equipment. 
15.1.3.2 
Add: “Audio amplifiers having an audio output not 
limited to 120V that are connected to the mains by 
a flexible cord shall have suitable cord or provision 
for field installation or a receptacle for plug-in 
connections,” 
 N 
15.2 
Add after 3rd paragraph: “The earthing conductor 
in a supply cord, or in an interconnecting cable 
shall have an equivalent or large cross-sectional 
area that the current-carrying conductors in the 
supply cord or cable. With reference to earthing 
conductors, the insulation color may be green or 
green/yellow. 
 N 
15.3.5 
Revise 2nd paragraph to read: “For rated currents 
exceeding 13A, reference is made to Article 310 of 
the National Electrical Code, ANSI/NFPA 70.” 
Table 15 – Replace with: “Normal cross-sectional 
area AWG” and modify values.   
Not such equipment. 
15.4 
Add: “Component power supply adaptors 
complying with the construction and test 
requirements on the clause.” 
 N 
16.1 
Modification: Mains supply flexible cords shall 
comply with UL 817, be marked VW-1, and have 
an ampacity not less than the current drawn by the 
apparatus. Delete reference to IEC 60227, 60245 
and 60173.  
Table 17A – Add: Types of cords and lengths for 
various types of apparatus. 
 N 
 
Page 56 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
16.2 
An integral earthing conductor shall be at least the 
same size as the other cord conductors. Substitute 
“IEC 60950, table 3B” with Article 400 of the 
National Electrical Code”. 
Table 18 – Replace with “Wire sizes of external 
flexible cords” Upper current limit in column 1 
increased from 16 to 30A and “AWG” wire sizes 
added. 
 N 
16.3 
Add: c) Flexible cords not complying with 16.1, 
used as connection between the apparatus and 
other apparatus used in combination with it, shall 
be marked VW-1. 
 N 
17.8 
Expanded to include all cart/stand parts supplied 
by the manufacturer, such as casters and 
brackets. Suitable assembly instructions required. 
Add: “Relevant fixing means are not required when 
installation is to be done by a skilled person.” 
 N 
17.10 
Add: Aluminum conductors used as internal wiring 
shall be terminated by a method capable of being 
used in the combination of metals involved at the 
connection point. 
No such conductor. 
17.11 
Add: An accessory shall be investigated to 
determine that: a) The accessory, and the 
combination of the accessory and the apparatus 
shall present no hazard in the sense of this 
standard and b) The accessory is provided with 
installation instructions. 
No other accessory. 
17.11.1 
Add: The installation of an accessory of a killed 
person shall be such that: a) The mechanical 
positioning is accomplished by means of tools 
normally available or by means of special tools 
provided by the organization responsible for 
providing the apparatus as part of the installation 
kit, and b) The electrical connections are made by 
using existing terminals and connections in the 
apparatus or the building wiring. 
 N 
18 
Modification: Non-intrinsically protected picture 
tubes shall comply with 18.1, 18.2.2 and 18.3. 
Intrinsically protected picture tubes shall comply 
with UL 1418 or UL 61965.  
Add: “A bulb of a picture tube having a face 
diameter of 7.5cm or more shall be mounted in an 
enclosure. The enclosure shall have no opening 
that exceeds 130 mm
2
 unless the minor dimension 
of the opening is 10 mm or less.” 
No such tube. 
 
Page 57 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
18.1 
All tubes shall be mounted such that the enclosure 
of the apparatus protects the tube against the 
effects of implosion. Delete reference to clause 
18.2. 
18.2, 18.2.1, and 18.2.3 are deleted..19-Add 
reference to 19.2.1. The test of 19.3 is conducted 
on 1) apparatus with direct view CRT with 48cm 
diagonal min., 2) apparatus, other than a speaker, 
with a mass greater than 47kg, and 3) apparatus, 
other than a speaker, with a mass or 25kg or 
greater and height of 1 m or more. The tests in 
19.1, 19.2 and 19.3 shall not cause the apparatus 
to overturn. During the test of 19.2.1, the 
apparatus shall not slide.  
 N 
19.2.1 
Add: Slide test requirements. 
Not such equipment. 
19.3 
Replace by Horizontal force stability test 
requirements. 
Add: table 20A – Values for  horizontal force test 
 N 
19.6 
Add: “or equipment rack mounting”.  
 
20.1a Delete 
 
20.1b 
Replace “IEC 60707” with “UL 94” 
Add: “-parts such as protection TV lenses, 
loudspeaker parts, external accessories, and 
fibrous materials less than 0.25mm thick.” 
 N 
20.1.2 
Revise text to read: “Sleeving, extruded tubing and 
insulation on wiring shall be rated VW-1 under 
following conditions: a) wiring located in a circuit 
that is considered a potential ignition source” or b) 
wiring not located in a circuit that is a potential 
ignition source but is in contact with wiring located 
in a circuit that is a potential ignition source. “Tape 
should be flame retardant.”  
Delete Note and add: “Tape in contact with parts of 
circuits that are potential ignition source shall be 
flame retardant.” 
 N 
 
Page 58 of 62 
Ref. No. : 06-1331-0461
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IECEN 60065F 
                                                             TRF originator BEAB 
 
20.1.3 
Replace 1st paragraph with: “Base material of 
printed wiring boards, or which the available power 
as the connection exceeds 15W or the operating 
voltage exceeds 50V a.c. or d.c. under normal 
operating conditions, shall be of flammability 
category V-1 or better according to UL 94.” 
In 2nd paragraph replace “IEC 60707” with “UL 94” 
and remove exception for printed boards housed in 
metal enclosures. 
In 3rd paragraph replace “IEC 60707” with “UL 94” 
and delete option to use Clause G.1 of Annex G. 
PCB: Min. V-1 
20.1.4 
Replace with: components and parts shall comply 
with the relevant flammability category according 
to UL 94 as specified in Table 21. Delete all other 
text. 
 N 
20.1.4 
Add: “Component power supplies complying with 
the construction and test requirements of UL 1310, 
UL 1950 Third Edition, or UL 60950 are 
considered to fulfill the test requirements on the 
clause.” 
Table 21 – Replace complete table with new table 
for “Flammability categories for components and 
parts.” 
 N 
20.2.1 
Modification: 1st paragraph: “Fire enclosure 
required for 1) circuits and components where the 
available power exceeds 15W, 2) inductors and 
windings conductively connected to the mains and 
3) high-voltage products. The fire enclosure shall 
comply with the flammability requirements of Table 
22 according to UL 94 and 746C. 2nd, 3rd, and 4th 
paragraphs are deleted. 
In 5th paragraph replace “IEC 60707 or clause G.1 
of Annex G” with “UL 94 or UL 746C.” 
Table 22 – Add “Flammability categories for fire 
enclosures.” 
 N 
20.2.2 
 N 
20.2.3 
Modification: Outer enclosures shall have a 
minimum flammability rating of HB, per UL 94, 
when an internal fire enclosure is provided. 
 N 
Page of 72