Page 51 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
8.22
Add: “Printed wiring boards involved with the risk
of electric shock shall comply with the
requirements in UL 796.”
of electric shock shall comply with the
requirements in UL 796.”
Comply with UL796
N
9.1.1.1
Replace: For Class I apparatus the r.m.s. TOUCH-
CURRENT to earth shall not be more than 3.5
MIU.
CURRENT to earth shall not be more than 3.5
MIU.
18 Vdc powered equipment
N
9.1.1.1a
2nd dash replaced by: “For audio signals of
professional and commercial apparatus, 120
Vrms.”
professional and commercial apparatus, 120
Vrms.”
3rd dash replaced by: ”For audio signals other than
professional and commercial apparatus, 71 Vrms.”
professional and commercial apparatus, 71 Vrms.”
N
9.1.1.1b
Modification: Touch current shall comply with the
American National Standard for Leakage Current
for Appliances, ANSI C101 and not exceed 0.5MIU
for Class II Delete Note 2.
American National Standard for Leakage Current
for Appliances, ANSI C101 and not exceed 0.5MIU
for Class II Delete Note 2.
N
9.1.1.2
UL articulated finger replaces IEC 61032 test
probe B. Delete 3rd paragraph.
probe B. Delete 3rd paragraph.
Table 5 – Add Note 1: “With respect to mains
voltages in the range of 105-130 V(rms), the test
voltages are considered to be 1414 V peak for
basic and supplementary insulation and 2828 V
peak for reinforced insulation.”
voltages in the range of 105-130 V(rms), the test
voltages are considered to be 1414 V peak for
basic and supplementary insulation and 2828 V
peak for reinforced insulation.”
N
11
Add: “Component power supplies and their power
transformers complying with the construction and
test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
transformers complying with the construction and
test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
N
11.1
Modification: The permissible touch current for
terminal contacts has been increased to twice the
value given in 9.1.1.1.
terminal contacts has been increased to twice the
value given in 9.1.1.1.
N
11.2.1
Modification: Additional fuse testing not required
if the temperature is limited by fuses.
if the temperature is limited by fuses.
N
12
Add: “Component power supply adaptors and
their enclosures complying with the construction
and test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
their enclosures complying with the construction
and test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
N
12.1.3
Delete the first two paragraphs. Impact test uses
the 50mm steel sphere only.
the 50mm steel sphere only.
Table 6 – Replace title with “Apparatus impact
test.” Table 6 modified to provide impact test
criteria detailing impact location, impact energy
and additional pass/fail results.”
test.” Table 6 modified to provide impact test
criteria detailing impact location, impact energy
and additional pass/fail results.”
N
Page 52 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
12.1.4
Add to the end of the 1st paragraph: “As an
alternative, any number form one to three
samples are permitted to be used in any
combination that results in a total of three drops.”
alternative, any number form one to three
samples are permitted to be used in any
combination that results in a total of three drops.”
N
12.1.6
Add: Handle strength test requirements.
No handle.
N
12.7
Add: Wall and ceiling mounting means test
requirements.
requirements.
Not such equipment.
N
12.8
Add test for enclosures, barriers, components
and leads that rely on adhesive.
and leads that rely on adhesive.
No such part.
N
12.8.1
Add test for conductive labels secured in place by
adhesive.
adhesive.
N
13
Add: “Component power supplies and their power
transformers complying with the construction and
test requirements of UL 1310, UL1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
transformers complying with the construction and
test requirements of UL 1310, UL1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
N
13.4
Modification: A material group is verified
according to UL 746A.
according to UL 746A.
N
13.5.1
Change standard reference from IEC 60249-2 to
UL 796.
UL 796.
N
13.5.2
Modification: Coated printed wiring boards shall
comply with requirements in UL 746C Table 12 –
note 3 revised to refer to UL 746A.
comply with requirements in UL 746C Table 12 –
note 3 revised to refer to UL 746A.
N
14
Delete Note 2. Add reference to Annex Y and
additional component requirements.
additional component requirements.
14.1, 14.2 and 14.3 – Add: “Component power
supplies and their resistors complying with the
construction and test requirements of Clause
14.1 and 14.2.1 – 14.5.2..14.2.1 and 14.2.2 –
Add: “As an alternative a component such as
capacitor, a combination capacitor and resistor, a
varistor, or a suppressor shall comply with the
requirements for Across-the Line, Antenna-
Coupling, or Double Protection in UL 1414.”
supplies and their resistors complying with the
construction and test requirements of Clause
14.1 and 14.2.1 – 14.5.2..14.2.1 and 14.2.2 –
Add: “As an alternative a component such as
capacitor, a combination capacitor and resistor, a
varistor, or a suppressor shall comply with the
requirements for Across-the Line, Antenna-
Coupling, or Double Protection in UL 1414.”
N
14.2.4
Replace text with: “Components subjected to the
requirements in 14.2.1 and 14.2.2 shall also
comply with the enclosure requirements of UL
1414.”
requirements in 14.2.1 and 14.2.2 shall also
comply with the enclosure requirements of UL
1414.”
N
14.4
Add to Note 2: “High voltage materials shall be
rated 94V-2 minimum.”
rated 94V-2 minimum.”
No such component.
N
14.4.1
Replace with High voltage arcing test.
N
14.4.2 Deleted.
N
14.4.3
Add: High voltage component part flame test.
N
Page 53 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
14.4.4
Add: High voltage isolation component insulation
test.
test.
N
14.5.1
Delete reference to 14.5.1.3.
N
14.5.1.1
Replace text with: Thermal cutouts shall comply
with UL 873, UL 8730-2-9 or UL 60730-2-9.
with UL 873, UL 8730-2-9 or UL 60730-2-9.
No such component.
N
14.5.1.2
Replace text with: “Thermal links shall comply
with UL 1020 or IEC 60691.”
with UL 1020 or IEC 60691.”
N
14.5.1.3
Delete.
N
14.5.2.1
Modification: Fuse links shall comply with UL 248-
14.
14.
N
14.5.2.2
Delete reference to IEC 60127 and breaking
capacity marking requirements.
capacity marking requirements.
N
14.5.3
Add: As an option, a PTC thermistor may comply
with UL 1434. Delete the 3rd and 4th paragraphs.
with UL 1434. Delete the 3rd and 4th paragraphs.
No such component.
N
14.5.3A
Add: Protective devices connected to the mains
shall have adequate breaking capacity and comply
with UL 873, UL1416, UL 1417 or UL 2111 as
applicable.
shall have adequate breaking capacity and comply
with UL 873, UL1416, UL 1417 or UL 2111 as
applicable.
N
14.5.4
Reference to fuse-links is deleted.
N
14.6.1
Add: “Switches and relays shall comply with UL
1054, UL 61058-1 or UL 508 as applicable. Mains
switch or relay shall be rated for the total current
through the switch or relay contacts.”
1054, UL 61058-1 or UL 508 as applicable. Mains
switch or relay shall be rated for the total current
through the switch or relay contacts.”
Replace remaining text with: “A rating of a mains
switch or relay, provided on a audio apparatus
intended for commercial use, is to be equal to or
greater than the maximum steady state current it
controls under normal operating conditions except
the audio output is adjusted to 1/3 maximum
undistorted output or at 1/3 of the 14.6.2, 14.6.3
and 14.6.4 are deleted.
switch or relay, provided on a audio apparatus
intended for commercial use, is to be equal to or
greater than the maximum steady state current it
controls under normal operating conditions except
the audio output is adjusted to 1/3 maximum
undistorted output or at 1/3 of the 14.6.2, 14.6.3
and 14.6.4 are deleted.
No switch controls exceeding
0,2A, 35 V peak a.c. or 24 V
d.c.
0,2A, 35 V peak a.c. or 24 V
d.c.
N
14.6.5
Modification: A switch or relay that controls a
mains socket-outlet shall have a rating equal to the
rated current consumption of the apparatus plus
the current rating of the socket-outlet.
mains socket-outlet shall have a rating equal to the
rated current consumption of the apparatus plus
the current rating of the socket-outlet.
N
14.6.6
Add: A mains switch shall comply with (a), (b) or
(c). The contacts of a mains relay shall comply with
(a), (b) or (d). A switch that controls a mains
receptacle shall comply with (b) and a relay that
controls a mains receptacle shall comply with (b)
or (d).
(c). The contacts of a mains relay shall comply with
(a), (b) or (d). A switch that controls a mains
receptacle shall comply with (b) and a relay that
controls a mains receptacle shall comply with (b)
or (d).
N
14.6.6a
Add: Switch or relay contacts to have current rating
equal to or greater than 1.414 times the inrush
current of the apparatus.
equal to or greater than 1.414 times the inrush
current of the apparatus.
N
Page 54 of 62
Ref. No. : 06-1331-0461
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IECEN 60065F
TRF originator BEAB
14.6.6b
Add: Switch or relay to be TV rated.
N
14.6.6c
Add: Switch is located on the back of apparatus
and is not operable from a remote control.
and is not operable from a remote control.
N
14.6.6d
Add: Relay is to be subjected to the endurance
test.
test.
N
14.6.6.1
Add: Peak inrush current test.
N
14.6.6.2
Add: Relay endurance test.
N
14.6.7
Add: Double pole switch controlling a.c. and d.c.
circuits shall be suitable for the application.
circuits shall be suitable for the application.
N
14.7
Add to the end of the 2nd paragraph“...except that
the jointed test finger to in 9.1.1 is used to
determine accessibility (IEC 60950, 2.8.2) and
interlock operation (IEC 60950, 2.8.3).”
the jointed test finger to in 9.1.1 is used to
determine accessibility (IEC 60950, 2.8.2) and
interlock operation (IEC 60950, 2.8.3).”
No interlock switch.
N
14.10.6
Add: “An apparatus intended for use with an
external battery shall be provided with an
overcurrent protective device in the battery-supply
circuit.”
external battery shall be provided with an
overcurrent protective device in the battery-supply
circuit.”
No battery.
N
14.11
Add: “Component power supplies and their
optocouplers complying with the construction and
test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
optocouplers complying with the construction and
test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
Optocouplers bridging reinforced insulation shall
comply with requirements for double protection as
specified in UL 1577.
comply with requirements for double protection as
specified in UL 1577.
4th paragraph reads: “External clearances and
creepage distances of optocouplers shall comply
with 13.1.”
creepage distances of optocouplers shall comply
with 13.1.”
N
14.12
Replace “IEC 61051-2” with “UL 1449” and “UL
94.” Delete all references to “IEC 60151” 15.1.1-
Add: “Attachment plug shall have a current rating
no less than 125% of the current drawn under
normal operating conditions and a voltage rating
appropriate for the rated voltage of the apparatus.
Attachment plugs for use on more than one supply
voltage by means of a voltage selector shall be
rated for the voltage, which the apparatus is
intended to be connected when it is shipped from
the factory. Attachment plug cap shall be polarized
when the apparatus is provided with a manually
operated, line connected, single-pole switch;
Edison-base lampholder; or a 15 or 20A socket
outlet.”
94.” Delete all references to “IEC 60151” 15.1.1-
Add: “Attachment plug shall have a current rating
no less than 125% of the current drawn under
normal operating conditions and a voltage rating
appropriate for the rated voltage of the apparatus.
Attachment plugs for use on more than one supply
voltage by means of a voltage selector shall be
rated for the voltage, which the apparatus is
intended to be connected when it is shipped from
the factory. Attachment plug cap shall be polarized
when the apparatus is provided with a manually
operated, line connected, single-pole switch;
Edison-base lampholder; or a 15 or 20A socket
outlet.”
No such components
N
15.1.2
Delete reference to “Banana” plug in the Note.
N