ATTACHMENT 1  
Nation Differences 
( 26 / 28 ) 
Report No. : 12-1330-0056 
 
TRF No. IEC60065K 
 
 
 
 
Day 10 or Day 59: 
1.  Place in f reezer at  
–35ºC for 2 h. 
2.  Remove and leave at  room t emperat ure f or 
1 h., 
3.  Place in humidit y chamber at  96%  relat ive 
humidit y f or 3 h. 
4.  Remove and allow  t o come t o room 
t emperat ure overnight . 
 
Day 11 or Day 60: 
1.  Place in oven at  t he t emperat ure select ed 
in t he f irst  cycle f or 3 h.  
2.  Remove f or 1 h.  
3.  Place in f reezer at  
–35ºC for 2 h. 
4.  Remove and allow  t o come t o room 
t emperat ure overnight .  
 
Day 12 or Day 61: 
1.  Place in humidit y chamber at  96%  relat ive 
humidit y f or 3 h. 
2.  Remove and perf orm mechanical t est s as 
required by Clause 17.9A.1  
as applicable. 
18 
Mechanical strength of picture tubes and protection against the effects of implosion 
18.1A 
 
 
(Cat hode Ray Tubes
Add t he f ollow ing clause:  
A pict ure t ube w it h a maximum f ace 
dimensions exceeding 75mm eit her shall be 
int rinsically prot ect ed w it h respect  t o ef f ect s 
of  implosion and t o mechanical impact , in 
accordance w it h CAN/CSA C22.2 No 228 or 
CAN/CSA E61965, or t he enclosure of  t he 
apparat us shall provide adequat e prot ect ion 
against  t he ef f ect s of  an implosion of  t he t ube 
(see Clause 12). 
No CRT. 
 
N/A 
 
19 
Stability and Mechanical Hazards  
Add t he f ollow ing af t er t he second paragraph:  
The t est  of  19.3 is only required f or: 
a)  Apparat us w it h a mass of  25 kg or more; 
or 
b)  Apparat us, excluding loudspeaker 
syst ems, w it h a height  of  1m or more; or 
c)  Apparat us, including loudspeaker 
syst ems, in combinat ion w it h a supplied 
or recommended cart  of  st and w it h a t ot al 
height  of  1m or more. 
 
N/A 
 
 
ATTACHMENT 1  
Nation Differences 
( 27 / 28 ) 
Report No. : 12-1330-0056 
 
TRF No. IEC60065K 
 
 
 
Add t he f ollow ing paragraph:  
 
Apparat us not  t est ed because it  is int ended t o 
be f ast ened in place shall be provided w it h 
t he f ollow ing w arning, marked on t he 
apparat us or on a durable label at t ached t o 
t he mains cord: 
“ WARNING: This apparatus must be securely 
at t ached t o t he f loor /w all per inst allat ion 
inst ruct ions. Tipping, shaking, or rocking t he 
machine may cause injury / death”  
 
N/A 
 
20 
Fire enclosure
 
20.2.1
(Project or Lamp Enclosure) 
Add t he f ollow ing clause:  
Enclosures of  apparat us cont aining high 
volt age or project ion lamps shall have a 
minimum f lammabilit y rat ing of  cat egory FV1 
according t o IEC 60707 at  t he minimum 
t hickness used. 
No project or. 
 
N/A 
 
Annex 

 
Apparatus to be connected to the 
telecommunications netw orks 
Replace t his annex w it h t he f ollow ing:  
Apparat us int ended f or direct  connect ion t o a 
TELECOMMUNICATION NETWORK shall 
comply w it h: 
 
a) Clause 19 of  CSA C22.2 No 1; or 
b) CAN/CSA C22.2 No. 60950.  
No TNV. 
 
N/A 
 
 
 
ATTACHMENT 1  
Nation Differences 
( 28 / 28 ) 
Report No. : 12-1330-0056 
 
TRF No. IEC60065K 
 
 
 
 
National differences for Korea 
Clause 
Requirement  +  Test  
Result  - Remark 
Verdict  
 
5.101 
Other marking; Wording “
”  or an 
inf ormat ion regulat ed in IEC Publicat ion 417 
giving high volt age w arning t o layman shall be 
marked, if  an apparat us cont ains a part  more 
t han 600volt s. 
<  600 V 
N/A 
15.1.1 
Plugs f or t he connect ion of  t he apparat us t o t he 
supply mains and socket  out let s f or providing 
mains pow er t o ot her apparat us shall comply 
w it h t he Korean requirement s (KSC8300 and 
8305). 
Comply w it h t he Korean 
requirement s 
31. 
 
Radio f requency int erf erence  
The apparat us shall comply w it h t he relevant  
CISPR requirement s.(EMC =  EMI +  EMS) 
 