DOWNLOAD JBL SOUNDFLY BT (serv.man3) Service Manual ↓ Size: 3.17 MB | Pages: 75 in PDF or view online for FREE

Model
SOUNDFLY BT (serv.man3)
Pages
75
Size
3.17 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
soundfly-bt-sm3.pdf
Date

JBL SOUNDFLY BT (serv.man3) EMC - CB Certificate ▷ View online

 
ATTACHMENT 1  
Nation Differences 
( 22 / 28 ) 
Report No. : 12-1330-0056 
 
TRF No. IEC60065K 
 
 
 
13.3.1 
General 
– loudspeaker voice coil 
 
Add t he f ollow ing af t er t he t hird paragraph:  
 
CLEARANCES bet w een a loudspeaker voice 
coil and adjacent  conduct ive part s shall be 
disregarded. 
 
N/A 
14.2 
Capacitors and RC-units
 
14.2.1 
(Y-Capacit ors) 
Add t he f ollow ing paragraph:  
As an alt ernat ive an isolat ing capacit or 
complying w it h applicable requirement s of  
CSA C22.2 No 1, shall be accept able f or 
bridging BASIC or SUPPLEMENTARY 
INSULATION. 
 
 
14.2.2 
(X-Capacit ors) 
Add t he f ollow ing paragraph: 
As an alt ernat ive an across-line capacit or 
complying w it h applicable requirement s of  
CSA C22.2 No 1, shall be accept able.  
 
14.5.1.
Thermal releases 
Add t he f ollow ing paragraph:  
As an alt ernat ive a THERMAL LINK complying 
w it h CSA C22.2 No 209 shall be accept able. 
Considered 
14.5.2 
Fuse-links and fuse holders 
14.5.2.
Add t he f ollow ing paragraph:  
As an alt ernat ive, a f use-link complying w it h 
CSA C22.2 No 248.14 shall be accept able.  
 
N/A 
14.5.2.
Add t he f ollow ing paragraph:  
As an alt ernat ive a Fuseholder Assembly 
complying w it h CSA C22.2 No 39 shall be 
accept able. 
 
N/A 
14.6 
Switches 
14.6.1 
t o 
14.6.5 
Add t he f ollow ing t o each of  t he Clauses:  
As an alt ernat ive, a TV-Rat ed Sw it ch 
complying w it h CSA C22.2 No 1 -98, Cl 9 
shall be accept able. 
 
N/A 
14.11 
Optocouplers 
Add t he f ollow ing paragraph:  
As an alt ernat ive, an opt ocoupler complying 
w it h CSA C22.2 No. 1 shall be accept able.  
 
14.12 
Surge suppression varistors 
Add t he f ollow ing paragraph:  
As an alt ernat ive, a varist or complying w it h 
CSA C22.2 No. 1 shall be accept able.  
No varist or. 
 
N/A 
 
 
ATTACHMENT 1  
Nation Differences 
( 23 / 28 ) 
Report No. : 12-1330-0056 
 
TRF No. IEC60065K 
 
 
 
14.12A 
Gas discharge tubes 
Add New  Clause 14.12A: 
 
Gas discharge t ubes complying w it h t he 
f ollow ing t est s may be connect ed t o bridge 
BASIC or REINFORCED INSULATION.  
 
Ten samples of  gas discharge t ubes isolat ing 
t he ac supply f rom exposed part s shall be 
subject ed t o t he varist or pulse t est s of  Clause 
14.12. Follow ing t he pulses, t he device shall 
be allow ed t o ret urn t o room t emperat ure. 
The dielect ric breakdow n volt age of  t he gas 
t ube shall not  decrease by more t han 50%  
and t he gas discharge t ube shall comply w it h 
t he elect ric st rengt h t est  of  Clause 10.3, w it h 
t he t est  volt age reduced t o t w ice t he mains 
volt age. 
No gas t ube. 
 
N/A 
 
15.1 
Plugs and sockets 
15.1.1 
(Convenience Recept acle Type) 
Add t he Follow ing Clause: 
A recept acle provided f or general purpose 
mains out put  shall comply w it h t he 
requirement s of  CSA St andard C22.2 No 42 
(dimensional requirement s are also specif ied 
in IEC 60906-2). The at t achment  plug cap 
shall be polarized t ype w hen t he apparat us is 
provided w it h a manually operat ed, MAINS 
connect ed single pole sw it ch f or apparat us 
on-of f  operat ion, a socket  screw shell 
lampholder, or a 15 or 20 A socket  out let .  
No socket  out let . 
 
N/A 
 
15.1.2 
(Audio Terminals
Add t he f ollow ing paragraph: 
Banana plugs shall be accept able.  
No banana plugs. 
 
N/A 
 
15.1.3 
Adapter output connectors 
Replace t he f irst  paragraph w it h t he f ollow ing:  
Terminals and connect ors used in out put  
circuit s of  supply apparat us, w hose out put  is 
not  a st andard nominal mains volt age 
according t o IEC 60038, Table 1, shall not  be 
compat ible w it h t hose specif ied f or household 
and similar general purposes, f or example 
t hose described in IEC 60083[1], IEC 60320, 
IEC 60884, IEC 60906 (part s 1, 2, and 3), 
and CSA C22.2 No 42. 
No mains out put . 
 
N/A 
 
15.2 
Provisions for protective earthing - Bond 
Impedance 
Replace t he t hird paragraph w it h t he 
f ollow ing: 
Eart hing connect ions shall comply w it h t he 
 
N/A 
 
ATTACHMENT 1  
Nation Differences 
( 24 / 28 ) 
Report No. : 12-1330-0056 
 
TRF No. IEC60065K 
 
 
 
t est  requirement s of  CSA C22.2 No 0.4.  
15.3 
Terminals for external flexible cords and permanent connections to the mains supply
 
15.3.1
(Permanent  Wiring) 
Add t he f ollow ing clauses: 
Equipment  int ended f or permanent  connect ion 
t o t he mains shall have provisions f or 
connect ion t o t he w iring syst em in 
accordance w it h t he Canadian Elect rical Code, 
Part  I. 
 
N/A 
 
The t erminal part s and all ot her provisions f or 
permanent  connect ion t o f ixed w iring shall 
comply w it h CSA St andard CAN/CSA -C22.2 
No 0. 
 
N/A 
 
15.4.2 
(Mains Plugs 
– Type) 
Add t he f ollow ing paragraphs:  
 
Mains plugs of  non-permanent ly inst alled 
equipment  shall comply w it h: 
a) 
CSA C22.2 No 21 for moulded-on type 
attachment plugs; and 
b) 
CSA C22.2 No 42 for disassembly type 
attachment plugs   (dimensional requirements 
are also specified in IEC 60906-2). 
 
 
Class II equipment  provided w it h a general 
purpose mains out let , or lampholder, shall be 
provided w it h a polarized-t ype plug.  
 
 
If  t he plug is a polarized t ype, single pole 
sw it ches or over current  prot ect ors shall not  
be connect ed in t he ident if ied conduct or.  
 
16 
External flexible cords
 
16.1 
Replace t his clause w it h t he f ollow ing:  
Flexible cord used f or mains supply shall 
comply w it h t he requirement s of  CSA C22.2 
No 49. The cord t ype shall be in accordance 
w it h Table 4 of  CSA C22.2 No 1. 
The at t achment  plug shall be rat ed not  less 
t han 125%  of  t he apparat us rat ed current .  
Cord set s shall comply w it h t he requirement s 
of  CSA C22.2 No 21. 
Non-det achable f lexible cables and cords of  
Class I apparat us shall be provided w it h a 
green/yellow  core connect ed t o t he prot ect ive 
eart hing t erminal of  t he apparat us and, if  a 
plug is provided, t o t he prot ect ive eart hing 
cont act  of  t he plug.  
Compliance is checked by inspect ion.  
Not e: The colour of  cores of  f lexible mains 
CSA Cert if ied. Plug rat ed 10 
A. 
 
ATTACHMENT 1  
Nation Differences 
( 25 / 28 ) 
Report No. : 12-1330-0056 
 
TRF No. IEC60065K 
 
 
 
cords is cont ained in IEC 60173[4].  
17.9A 
Adhesive securement and conductive coatings
 
17.9A.
Add t he f ollow ing clause:  
 
Adhesive securement
 
The f ollow ing part s, t he displacement  of  
w hich may result  in a f ire or shock hazard, 
shall not  be secured solely by adhesive, 
unless t he adhesive syst em complies w it h t he 
resist ance t o ext ernal f orces t est  of  Clause 
9.1.7, t he bump t est  of  Clause 12.1.1, and 
t he impact  t est  of  Clause 12.1.3, af t er 
condit ioning in accordance w it h Clause 
17.9A.2: 
a)  int ernal met al part s/conduct ive coat ings;  
b)  barriers; and 
c)  required enclosure part s. 
Not e: Cat hode ray t ubes are excluded f rom 
t his t est . 
Adhesives/Conduct ive 
coat ing not  used. 
 
N/A 
 
 
17.9A.
Adhesive and conductive coating securement conditioning
 
17.9A.
2.1 
General:   
Where required by Clause 17.9A.1, one 
sample of  t he apparat us or enclosure sect ion 
shall be condit ioned in accordance w it h t he 
requirement s of  Clause 17.9A.2.2.  
Equivalent  ageing t est  dat a supplied by t he 
manuf act urer w ill be considered in lieu of  
ageing. 
 
N/A 
 
17.9A.2.
Ageing 
 
Day 1:
  Place in oven at  100 ±  1ºC f or 1 
w eek, or 82 ±  1ºC f or 8 w eeks at  t he 
manufacturer’ s option. 
Day 8 or Day 57: 
1.  Remove f rom oven and leave at  room 
t emperat ure f or 1 h. 
2.  Place in f reezer at  
–35ºC for 2 h. 
3.  Remove f rom f reezer and allow  t o reach 
room t emperat ure overnight . 
 
Day 9 or Day 58: 
1.  Place in a compart ment  at  96%  relat ive 
humidit y f or 3 h. 
2.  Remove and leave at  room t emperat ure 
and humidit y f or 1 h.  
3.  Place in over at  a t emperat ure select ed in 
t he f irst  cycle f or 3 h.  
4.  Remove and allow  t o come t o room 
t emperat ure overnight .  
 
N/A 
 
Page of 75