Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
14.7 
Safety interlocks  
No safety interlocks. 
N/A 
 
Safety interlocks to 2.8 of IEC 60950  
 
N/A 
14.8 
Voltage setting devices and the like  
No voltage setting devices. 
N/A 
 
Voltage setting device not likely to be changed 
accidentally  
 
N/A 
14.9 Motors 
 
N/A 
14.9.1 
Endurance test on motors  
No motors. 
N/A 
 
Motor start test  
 
N/A 
 
Dielectric strength test  
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc.   
 
N/A 
14.9.3 
Protection against moving parts  
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950, Annex B  
 
N/A 
14.10 Batteries 
 
N/A 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases  
No batteries. 
N/A 
14.10.2 
No possibility of recharging non-rechargeable 
batteries  
 
N/A 
14.10.3 
Recharging currents and times within manufacturers 
limits  
 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits  
 
N/A 
14.10.4 
Battery mould stress relief  
 
N/A 
14.10.5 
Battery drop test  
 
N/A 
14.11 Optocouplers 
 
 P 
 
Optocouplers comply with Cl. 8  
Insulation thickness > 0.4mm
 
 
 
Page 22 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
14.12 
Surge suppression varistors  
No surge suppression varistors 
N/A 
 
Comply with IEC 61051-2  
 
N/A 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus  
 
N/A 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12  
 
N/A 
 
15 Terminals 
 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard  
Approved appliance inlet, plug 
and coupler provided.  
See appended table, list of  
critical components. 
 
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets  
No mains socket-outlets 
N/A 
 
Overloading of internal wiring prevented if the 
apparatus has mains socket outlets  
No mains socket-outlets 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or  
data  
 
 
No risk of insertion in mains socket-outlets  
Signal I/O connectors are so 
designed that plug insertion  
into mains socket-outlet or 
appliance is unlikely to occur. 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2  
No sockets indicated with  
the symbol. 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets 
The equipment under test is  
not an adaptor. 
N/A 
15.2 
Provision for protective earthing 
 
N/A 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment  
Class II apparatus. 
N/A 
 
Protective earth conductors correctly coloured  
 
N/A 
 
Equipment with non-detachable mains cord provided 
with separate protective earth terminal near mains 
input  
 
N/A 
 
Protective earth terminal resistant to corrosion  
 
N/A 
 
Earth resistance test: < 0,1 
 at 25 A ……….: 
 
N/A 
 
Page 23 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
 
N/A 
15.3.1 
Adequate terminals for connection of permanent 
wiring  
Appliance inlet applied 
N/A 
15.3.2 
Reliable connection of non-detachable cords  
 N/A 
 
Not soldered to conductors of a printed circuit board 
 
N/A 
 
Adequate clearances and creepage distances 
between connections should a wire break away  
 N/A 
 
Wire secured by additional means to the  
conductor   
 N/A 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar  
 N/A 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means  
Appliance inlet applied 
N/A 
 
Clamping of conductor and insulation if not soldered 
or held by screws  
 N/A 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment  
 N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16 
 N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure  
 N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened  
 
N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided  
 
N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic  
 N/A 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other  
 N/A 
 
Terminals located and shielded: test with 8 mm 
strand  
 N/A 
15.4 
Devices forming a part of the mains plug  
 N/A 
15.4.1 
No undue strain on mains socket-outlets  
The apparatus in not a  
device forming a part of the  
mains plug. 
N/A 
 
Page 24 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
15.4.2 
Device complies with standard for dimensions of 
mains plugs  
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c)  
 
N/A 
 
16 
External flexible cords 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords ……………………………………….: 
Sheathed PVC cord  
complying with 
IEC 60227
. 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth  
Class II apparatus 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment  
The cord is 0.75mm²,  
within the current rating. 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength  
No interconnecting cables  
comprising hazardous live  
conductors. 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of IEC 60227-2) 
Cord complying with 16.1. 
N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions  
Cords have adequate  
cross-sectional areas to avoid 
temperature rise under normal 
and fault conditions. 
16.5 
Adequate strain relief on external flexible cords  
Appliance inlet provided 
N/A 
 
Not possible to push cord back into equipment  
 
N/A 
 
Strain relief device unlikely to damage flexible  
cord  
 
N/A 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth conductor 
Class II apparatus. 
N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement in 
use  
Appliance inlet provided 
N/A 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet to 
IEC 60320-1  
Appliance inlet complying with  
IEC 60320-1
 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord  
Appliance inlet provided
 
N/A 
 