JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate ▷ View online
Page 21 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
14.7
Safety interlocks
No safety interlocks.
N/A
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices and the like
No voltage setting devices.
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9 Motors
N/A
14.9.1
Endurance test on motors
No motors.
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
N/A
14.10 Batteries
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
No batteries.
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within manufacturers
limits
limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11 Optocouplers
P
Optocouplers comply with Cl. 8
Insulation thickness > 0.4mm
P
P
Page 22 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
14.12
Surge suppression varistors
No surge suppression varistors
N/A
Comply with IEC 61051-2
N/A
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus
except for earthed parts of permanently connected
apparatus
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N/A
15 Terminals
15.1.1
Mains plug, appliance inlet, interconnection couplers
and mains socket-outlet meet the appropriate
standard
and mains socket-outlet meet the appropriate
standard
Approved appliance inlet, plug
and coupler provided.
and coupler provided.
See appended table, list of
critical components.
critical components.
P
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets
the apparatus has mains socket outlets
No mains socket-outlets
N/A
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
apparatus has mains socket outlets
No mains socket-outlets
N/A
15.1.2
Connectors for antenna, earth, audio, video or
data
P
No risk of insertion in mains socket-outlets
Signal I/O connectors are so
designed that plug insertion
into mains socket-outlet or
appliance is unlikely to occur.
designed that plug insertion
into mains socket-outlet or
appliance is unlikely to occur.
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
No sockets indicated with
the symbol.
the symbol.
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-outlets
not compatible with household mains socket-outlets
The equipment under test is
not an adaptor.
not an adaptor.
N/A
15.2
Provision for protective earthing
N/A
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II apparatus.
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord provided
with separate protective earth terminal near mains
input
with separate protective earth terminal near mains
input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance test: < 0,1
at 25 A ……….:
N/A
Page 23 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
N/A
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
Appliance inlet applied
N/A
15.3.2
Reliable connection of non-detachable cords
N/A
Not soldered to conductors of a printed circuit board
N/A
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
N/A
Wire secured by additional means to the
conductor
N/A
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N/A
15.3.4
Soldered conductors wrapped around terminal prior
to soldering or held in place by additional means
to soldering or held in place by additional means
Appliance inlet applied
N/A
Clamping of conductor and insulation if not soldered
or held by screws
or held by screws
N/A
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of
the equipment
sectional area of conductors, for the rated current of
the equipment
N/A
15.3.6
Terminals to 15.3.3 have sizes required by table 16
N/A
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening when
the clamping is tightened or loosened and stress on
internal wiring is avoided
the clamping is tightened or loosened and stress on
internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N/A
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
N/A
Terminals located and shielded: test with 8 mm
strand
strand
N/A
15.4
Devices forming a part of the mains plug
N/A
15.4.1
No undue strain on mains socket-outlets
The apparatus in not a
device forming a part of the
mains plug.
device forming a part of the
mains plug.
N/A
Page 24 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N/A
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N/A
16
External flexible cords
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ……………………………………….:
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ……………………………………….:
Sheathed PVC cord
complying with
complying with
IEC 60227
.
P
Non-detachable cords for Class I have green/yellow
core for protective earth
core for protective earth
Class II apparatus
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
The cord is 0.75mm²,
within the current rating.
within the current rating.
P
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
No interconnecting cables
comprising hazardous live
conductors.
comprising hazardous live
conductors.
N/A
b) Flexible cords not complying with 16.1, withstand
bending and mechanical stress (3.2 of IEC 60227-2)
bending and mechanical stress (3.2 of IEC 60227-2)
Cord complying with 16.1.
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
Cords have adequate
cross-sectional areas to avoid
temperature rise under normal
and fault conditions.
cross-sectional areas to avoid
temperature rise under normal
and fault conditions.
P
16.5
Adequate strain relief on external flexible cords
Appliance inlet provided
N/A
Not possible to push cord back into equipment
N/A
Strain relief device unlikely to damage flexible
cord
N/A
For mains cords of Class I equipment, hazardous
live conductors become taut before earth conductor
live conductors become taut before earth conductor
Class II apparatus.
N/A
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement in
use
damage to the cord during assembly or movement in
use
Appliance inlet provided
N/A
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet to
IEC 60320-1
fitted with detachable cord set with appliance inlet to
IEC 60320-1
Appliance inlet complying with
IEC 60320-1
P
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
Appliance inlet provided
N/A
Click on the first or last page to see other ON BEAT XTREME (serv.man8) service manuals if exist.