JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate ▷ View online

 
Page 13 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
8.19.2 
Mains switch ON indication  
By indicator lamp. 
8.20 
Switch not fitted in the mains cord  
 
8.21 
Bridging components comply with clause 14  
No such components. 
N/A 
8.22 
Non-separable thin sheet material  
No non-separable thin sheet 
material. 
N/A 
 
Electric shock hazard under normal operating conditions 
 
9.1 
Testing on the outside 
P 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No voltage exceeding 
1000V ac or 1500V dc.  
N/A 
9.1.1.1 
a) Open circuit voltages  
Mains input voltage > 35 Vac,  
see below. 
 
 
b) Touch current measured from terminal devices 
using the network in annex D ………………: 
(see appended table 9.1.1.1)
 
 
c) Discharge not exceeding 45 μC  
No part or contact of a  
terminal with stored voltages 
between 60V - 15 kV. 
N/A 
 
d) Energy of discharge not exceeding 350 mJ  
No part or contact of a terminal 
with stored voltages exceeding 
15kV. 
N/A 
9.1.1.2 
Test with test finger and test probe  
No access to hazardous  
live parts 
9.1.2 
No hazardous live shafts of knobs, handles or levers 
No live shaft, handles or levers 
N/A 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
No opening on top side of the 
enclosure. 
N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
Does not reach hazardous  
live parts 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
Does not reach hazardous  
live parts 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No preset controls 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s: 
48V after 2 s, 
(Tested voltage at 264V) 
Bleeder resistors provided. 
See clause 14.1 b)  
 
If C is not greater than 0,1 μF no test needed  
> 0.1 uF 
N/A 
 
Page 14 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
9.1.7 
Resistance to external forces 
 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
Test with test finger result  
in no hazard 
 
b) Test hook of fig. 4 for 10 s (20 N)  
Test with test hook results 
in no hazard. 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
Tested with 100N results in  
no damage. 
9.2 
No hazard after removing a cover by hand  
No cover removable by hand 
N/A 
 
10 Insulation 
requirements 
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation …………………………..: 
> 100 M
 after surge test P 
10.2 
Humidity treatment 48 h or 120 h …….: 
Performed for 120 h at temp. 
40
C and relative humidity 93% 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
(see appended table 10.3) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class 1)  
Class II apparatus 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
(see appended table 10.3) 
 
11 Fault 
conditions 
 
11.1 
No shock hazard under fault condition  
No electric shock hazard  
under fault conditions. 
11.2 
Heating under fault condition  
(see appended table 11.2) 
 
Flames extinguish within 10 seconds  
No flames 
 
No hazard from softening solder  
No softening of solder 
 
Soldered terminations not used  as protective 
mechanism  
No soldered terminations 
11.2.1 
Measurement of temperature rises  
(see appended table 11.2) 
11.2.2 
Temperature rise of accessible parts  
(see appended table 11.2) 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation  
(see appended table 11.2) 
 
Page 15 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min  
No exceeding the limits of  
Table 3. 
N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not more 
than 100 K for an area not greater than 2 cm² : 
 
N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min  
 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted  
No conductors are interrupted/ 
peeled/ loosened during fault 
conditions 
N/A 
 
Class I protective earthing maintained  
Class II equipment. 
N/A 
11.2.4 
Temperature rise of parts acting as a support or  
mechanical barrier  
(see appended table 11.2) 
11.2.5 
Temperature rise of windings  
(see appended table 11.2) 
11.2.6 
Temperature rise of parts not subject to the limits of 
11.2.1 to 11.2.5  
No excessive temperature  
observed/measured on  
other parts. 
(see appended table 11.2) 
 
12 Mechanical 
strength 
 
12.1.1 
Bump test where mass >7 kg  
Mass: 4.1kg 
N/A 
12.1.2 
Vibration test  
Test conducted, no damage  
in the sense of this standard 
12.1.3 
Impact hammer test  
No damage in the sense  
of this standard 
 
Steel ball test  
No damage in the sense  
of this standard 
12.1.4 
Drop test for portable apparatus where mass ≤ 7 kg 
No damage in the sense  
of this standard 
12.1.5 
Thermoplastic enclosures stress relief test  
Tested, 70 
o
C
, 7h. 
No damage in the sense of  
this standard 
12.2 
Fixing of knobs, push buttons, keys and levers  
Normal use will not impair 
the protection against electric  
shock 
12.3 
Remote controls with hazardous live parts  
No remote control containing 
hazardous live parts 
N/A 
 
Page 16 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
12.4 
Drawers (pull test 50 N, 10 s)  
No drawers. 
N/A 
12.5 
Antenna coaxial sockets providing isolation  
No antenna socket.  
N/A 
12.6 
Telescoping or rod antennas construction  
No telescoping or rod antennas 
N/A 
12.6.1 
Telescoping or rod antennas securement  
 
N/A 
 
13 
Clearances and creepage distances 
 
13.1 
Clearances in accordance with 13.3  
See 13.3 
 
Creepage distances in accordance with 13.4  
See 13.4 
13.2 
Determination of operating voltage  
Conventional transformer used.
Upper rated supply voltage  
(240V) applied in determining  
the operating voltage
 
13.3 Clearances 
 
2N for internal parts and 30N  
for enclosures are considered 
when determining clearances. 
13.3.1 General 
 
Considered 
13.3.2 
Circuits conductively connected to the mains comply 
with table 8 and, where applicable, table 9.: 
(see appended table 13) 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10  
No hazardous secondary 
voltages 
N/A 
13.3.4 
Measurement of transient voltages  
No measurement of transient 
voltages 
N/A 
13.4 
Creepage distances  
CTI > 100 
(see appended table 13) 
 
Creepage distances greater than table 11 minimum 
values  
Not applicable 
N/A 
13.5 
Printed boards  
Refer to below 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10  
No such PCB used 
N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only)  
No type B coated printed  
circuit boards 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 13.3 
and 13.4  
No uncemented joints 
N/A 