JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate ▷ View online
Page 13 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
8.19.2
Mains switch ON indication
By indicator lamp.
P
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
No such components.
N/A
8.22
Non-separable thin sheet material
No non-separable thin sheet
material.
material.
N/A
9
Electric shock hazard under normal operating conditions
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No voltage exceeding
1000V ac or 1500V dc.
1000V ac or 1500V dc.
N/A
9.1.1.1
a) Open circuit voltages
Mains input voltage > 35 Vac,
see below.
see below.
b) Touch current measured from terminal devices
using the network in annex D ………………:
using the network in annex D ………………:
(see appended table 9.1.1.1)
P
c) Discharge not exceeding 45 μC
No part or contact of a
terminal with stored voltages
between 60V - 15 kV.
terminal with stored voltages
between 60V - 15 kV.
N/A
d) Energy of discharge not exceeding 350 mJ
No part or contact of a terminal
with stored voltages exceeding
15kV.
with stored voltages exceeding
15kV.
N/A
9.1.1.2
Test with test finger and test probe
No access to hazardous
live parts
live parts
P
9.1.2
No hazardous live shafts of knobs, handles or levers
No live shaft, handles or levers
N/A
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No opening on top side of the
enclosure.
enclosure.
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Does not reach hazardous
live parts
live parts
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Does not reach hazardous
live parts
live parts
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No preset controls
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s:
of the mains plug; voltage (V) after 2 s:
48V after 2 s,
(Tested voltage at 264V)
Bleeder resistors provided.
(Tested voltage at 264V)
Bleeder resistors provided.
See clause 14.1 b)
P
If C is not greater than 0,1 μF no test needed
> 0.1 uF
N/A
Page 14 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
9.1.7
Resistance to external forces
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
Test with test finger result
in no hazard
in no hazard
P
b) Test hook of fig. 4 for 10 s (20 N)
Test with test hook results
in no hazard.
in no hazard.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N)
Tested with 100N results in
no damage.
no damage.
P
9.2
No hazard after removing a cover by hand
No cover removable by hand
N/A
10 Insulation
requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation …………………………..:
surge test for basic and 4 MΩ min. for reinforced
insulation …………………………..:
> 100 M
after surge test P
10.2
Humidity treatment 48 h or 120 h …….:
Performed for 120 h at temp.
40
40
C and relative humidity 93%
P
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
Class II apparatus
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
(see appended table 10.3)
P
11 Fault
conditions
11.1
No shock hazard under fault condition
No electric shock hazard
under fault conditions.
under fault conditions.
P
11.2
Heating under fault condition
(see appended table 11.2)
P
Flames extinguish within 10 seconds
No flames
P
No hazard from softening solder
No softening of solder
P
Soldered terminations not used as protective
mechanism
mechanism
No soldered terminations
P
11.2.1
Measurement of temperature rises
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table 11.2)
P
Page 15 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
No exceeding the limits of
Table 3.
Table 3.
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm² :
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm² :
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
No conductors are interrupted/
peeled/ loosened during fault
conditions
peeled/ loosened during fault
conditions
N/A
Class I protective earthing maintained
Class II equipment.
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
(see appended table 11.2)
P
11.2.5
Temperature rise of windings
(see appended table 11.2)
P
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5
11.2.1 to 11.2.5
No excessive temperature
observed/measured on
other parts.
(see appended table 11.2)
observed/measured on
other parts.
(see appended table 11.2)
P
12 Mechanical
strength
12.1.1
Bump test where mass >7 kg
Mass: 4.1kg
N/A
12.1.2
Vibration test
Test conducted, no damage
in the sense of this standard
in the sense of this standard
P
12.1.3
Impact hammer test
No damage in the sense
of this standard
of this standard
P
Steel ball test
No damage in the sense
of this standard
of this standard
P
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg
No damage in the sense
of this standard
of this standard
P
12.1.5
Thermoplastic enclosures stress relief test
Tested, 70
o
C
, 7h.
No damage in the sense of
this standard
this standard
P
12.2
Fixing of knobs, push buttons, keys and levers
Normal use will not impair
the protection against electric
shock
the protection against electric
shock
P
12.3
Remote controls with hazardous live parts
No remote control containing
hazardous live parts
hazardous live parts
N/A
Page 16 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
12.4
Drawers (pull test 50 N, 10 s)
No drawers.
N/A
12.5
Antenna coaxial sockets providing isolation
No antenna socket.
N/A
12.6
Telescoping or rod antennas construction
No telescoping or rod antennas
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
Clearances and creepage distances
13.1
Clearances in accordance with 13.3
See 13.3
P
Creepage distances in accordance with 13.4
See 13.4
P
13.2
Determination of operating voltage
Conventional transformer used.
Upper rated supply voltage
(240V) applied in determining
the operating voltage
Upper rated supply voltage
(240V) applied in determining
the operating voltage
P
13.3 Clearances
2N for internal parts and 30N
for enclosures are considered
when determining clearances.
for enclosures are considered
when determining clearances.
P
13.3.1 General
Considered
P
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9.:
with table 8 and, where applicable, table 9.:
(see appended table 13)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
No hazardous secondary
voltages
voltages
N/A
13.3.4
Measurement of transient voltages
No measurement of transient
voltages
voltages
N/A
13.4
Creepage distances
CTI > 100
(see appended table 13)
(see appended table 13)
P
Creepage distances greater than table 11 minimum
values
values
Not applicable
N/A
13.5
Printed boards
Refer to below
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
No such PCB used
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
No type B coated printed
circuit boards
circuit boards
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with 13.3
and 13.4
clearances and creepage distances comply with 13.3
and 13.4
No uncemented joints
N/A