JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate ▷ View online
Page 29 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
L. 5
Marking and instructions
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used
apparatus indicating type or model number of flash
apparatus with which it is to be used
No electronic flash apparatus
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
model number of battery chargers or Supply
apparatus with which it is to be used
N/A
L. 7
Heating under normal operating conditions
N/A
L7.1.5 &
L11.2.6
Lithium batteries meet permissible temp rise in Table
3 , unless comply with 6.2.2.1.or 6.2.2.2 of IEC
60086-4
3 , unless comply with 6.2.2.1.or 6.2.2.2 of IEC
60086-4
No lithium batteries
N/A
L. 9
Electric shock hazard under normal operating
conditions
conditions
Not flash synchroniser.
N/A
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L.10 Insulation
requirements
N/A
L. 10.3.2
High frequency puls ignition
N/A
L. 12
Mechanical strength
N/A
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test
impact test
N/A
L. 14
Components
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE
to be a POTENTIAL IGNITION SOURCE
N/A
Page 30 of 42
Report No.: 171153
TRF No. IEC60065J
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by…..:
Less than 0.51W
—
Position of the functional switch (W) ……..:
-
—
Operating conditions
Standby mode at 50/60Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
240 0.045 / 0.053
0.51 / 0.50
—
230 0.041 / 0.050
0.49 / 0.50
—
100 0.022 / 0.024
0.36 / 0.36
—
Measured at maximum non-clipped output mode with loaded 5V/2.1A through ipad terminal at 50/60Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
264
0.65 / 0.63
96.7 / 96.0
Main : 2 x 24.0 W
Tweeter : 2 x LT 0.1 W
240
0.70 / 0.71
96.5 / 96.8
100
1.32 / 1.33
96.1 / 96.6
90
1.50 / 1.52
98.0 / 98.6
Measured at 1/8 of maximum non-
clipped output mode with loaded 5V/2.1A through ipad terminal at 50/60Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
264
0.23 / 0.25
33.0 / 33.0
*)
Main : 2 x 3.0 W
240
0.25 / 0.26
32.8 / 32.9
100
0.44 / 0.44
32.8 / 32.8
90
0.48 / 0.49
32.9 / 33.0
Tested condition:
1 kHz sign wave input signal with connected 4 pieces of 4 ohms loads for main and tweeter speaker outputs.
1 kHz sign wave input signal with connected 4 pieces of 4 ohms loads for main and tweeter speaker outputs.
*) Measured Pmax output for tweeter is too small (less than 0.1W) and not affecting in power consumption,
therefore ignored tweeter output during the measurements of 1/8 Pmax operation.
therefore ignored tweeter output during the measurements of 1/8 Pmax operation.
Loudspeaker impedance (Ω) :
4
for main and tweeter speakers
—
Several loudspeaker systems
Right and Left for main and tweeter output.
—
Marking of loudspeaker terminals
No loudspeaker terminals
(built-in speakers)
(built-in speakers)
N/A
Page 31 of 42
Report No.: 171153
TRF No. IEC60065J
7.1
TABLE: temperature rise measurements
P
Monitored point:
dT (K) at
90V/60Hz
dT (K) at
264V/60Hz
dT (K) at
90V/50Hz
dT (K) at
264V/50Hz
Permitted
dT (K) *)
Line filter, LF91 coil
28.6
22.9
27.9
24.6
75 **)
Line filter, LF92 coil
23.6
19.7
22.5
21.6
75 **)
PWB near DB91
35.9
28.7
35.4
30.5
95
Body of C904
22.3
24.7
22.2
26.5
105
C
Q901 heat-sink
24.9
37.5
23.6
39.2
-
PWB near Q901
26.0
34.8
24.9
36.5
95
Transformer, TF92 coil
32.2
35.0
31.4
36.6
85 **), ***)
Transformer, TF92 core
31.4
33.2
30.6
34.7
95 ***)
Transformer, TF91 coil
50.5
51.3
50.0
52.7
85 **), ***)
Transformer, TF91 core
45.1
44.6
44.5
46.0
95 ***)
D926 heat-sink
36.3
37.3
35.7
38.5
-
Amp IC heat-sink
51.4
48.5
50.4
49.7
-
AC Inlet, JK71
9.7
9.1
8.5
10.2
60
Enclosure, top (non-metallic)
12.5
12.1
10.9
13.4
60
Button, standby (non-metallic)
6.6
6.2
5.6
7.0
50
Handle (non-metallic)
5.0
4.4
3.6
5.4
50
Grill, speaker (metallic)
6.1
5.5
4.8
6.9
40
Ambient
23.6 °C
23.8 °C
24.6 °C
22.3 °C
-
*) Temperature rise limits for Singapore is 10K less.
**) Minus (-) 10K applied for thermo-couple method for windings.
***) For US difference, the insulation system does not cover the UL1446 insulation system for Class B,
therefore considered to Class A insulation (105 °C), and not applicable for info. followed *) for Singapore.
therefore considered to Class A insulation (105 °C), and not applicable for info. followed *) for Singapore.
Page 32 of 42
Report No.: 171153
TRF No. IEC60065J
7.2
TABLE: softening temperature of thermoplastics
P
Temperature T of part
T – normal
conditions (
o
C)
T – fault
conditions (
o
C)
Min T softening
(
o
C)
Coil base of line filter (LF92).
21.6 (43.9 °C)
(I/P=264V,
ambient 22.3 °C)
(I/P=264V,
ambient 22.3 °C)
22.7 (45.9 °C)
(I/P=264V,
ambient 23.2 °C)
(I/P=264V,
ambient 23.2 °C)
> 200
o
C
9.1.1.1
Touch current expressed as voltages U1 and U2 in Annex D
P
Location
Measured
U1V (peak)
U1V (peak)
Measured
U1 V (DC)
U1 V (DC)
Measured
U2 V (peak)
U2 V (peak)
Limits :
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
Pole 1 – RCA terminal
Pole 2 – RCA terminal
Pole 2 – RCA terminal
0.60
0.60
0.60
-
-
-
0.34V peak
0.34V peak
0.34V peak
Pass
Pass
Pass
Pole 1 – other part or contact
Pole 2 – other part or contact
Pole 2 – other part or contact
0.60
0.60
0.60
-
-
-
0.34V peak
0.34V peak
0.34V peak
Pass
Pass
Pass
Comments:
Vin = 264Vac / 60Hz
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
> 100
Min
2
Between parts separated by double or reinforced insulation
> 100
Min
4
Between mains poles (primary fuse disconnected)
after surge, humidity, drop and fault condition tests.
after surge, humidity, drop and fault condition tests.
> 100
Min
2
Between parts separated by double or reinforced insulation
after surge, humidity, drop and fault condition tests.
after surge, humidity, drop and fault condition tests.
> 100
Min
4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
1500 Vac
No
Between parts separated by double or reinforced insulation
3000 Vac
No
Mains poles (primary fuse disconnected)
after surge, humidity, drop and fault condition tests.
after surge, humidity, drop and fault condition tests.
1500 Vac
No
Between parts separated by double or reinforced insulation
after surge, humidity, drop and fault condition tests.
after surge, humidity, drop and fault condition tests.
3000 Vac
No
Click on the first or last page to see other ON BEAT XTREME (serv.man8) service manuals if exist.