JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate ▷ View online
Page 9 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
5.2
Earth terminal
Class II apparatus.
N/A
Hazardous live terminals
No hazardous live terminals.
N/A
Supply output terminals (other than mains)
No socket outlet for providing
power to other apparatus
power to other apparatus
N/A
5.3
Use of triangle with exclamation mark
Correct symbol applied:
- On name plate label, and
- In circuit diagram.
Further; no incorrect use of
this symbol is found.
- On name plate label, and
- In circuit diagram.
Further; no incorrect use of
this symbol is found.
P
5.4
Instructions for use
User information in the
following language: English.
See comments in Summary
of Testing.
following language: English.
See comments in Summary
of Testing.
P
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
dripping or splashing. Warning concerning objects
filled with liquid, etc.
The user manual includes
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
information about danger
concerning dripping or
adequate instructions supplied
splashing and objects filled
with liquids.
P
b) Hazardous live terminals, instructions for wiring
No hazardous live terminals
N/A
c) Instructions for replacing lithium battery
No battery.
N/A
d) Class I earth connection warning
Class II apparatus
N/A
e) Instructions for multimedia system connection
Not applicable
N/A
f) Special stability warning for attachment of the
apparatus to the floor/wall
apparatus to the floor/wall
No such equipment
N/A
g) Warning: battery exposure to heat
No battery
N/A
h) Warning: protective film on CRT face
No CRT
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
Plug is regarded as disconnect
device and is readily operable.
device and is readily operable.
P
c) Instructions for permanently connected equipment
Not permanent connected
equipment
equipment
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
disconnection from the mains
Information provided in user
manual.
manual.
P
Page 10 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
6 Hazardous
radiation
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation
N/A
Ionizing radiation under fault condition
N/A
6.2
Laser radiation, emission limits to IEC 60825-1….: No laser radiation
N/A
Emission limits under fault conditions …………..:
N/A
7
Heating under normal operating conditions
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
fuse links and other protective devices defeated
No fuse links operate during
normal operating operation.
(see appended table 7.1)
normal operating operation.
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table 7.1)
P
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
Appliance inlet is certified by
IEC/EN 60320-1
IEC/EN 60320-1
Bobbins for TF91, TF92 and
LF91 are made of Phenolic.
See appended table 7.2 for
Coil base of LF92 line filter.
LF91 are made of Phenolic.
See appended table 7.2 for
Coil base of LF92 line filter.
P
8
Constructional requirements with regard to the protection against electric shock
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Operation “By hand” not
possible
possible
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic materials used
N/A
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the removal
of a cover which can be removed by hand
from parts rendered accessible following the removal
of a cover which can be removed by hand
No cover removable by hand.
N/A
Page 11 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
8.5
Class I equipment
Class II equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
No such resistors
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
No such capacitors
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Class II equipment
P
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
Double/Reinforced insulation
complies with requirements
specified in clause 10 and 13.
complies with requirements
specified in clause 10 and 13.
P
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
The apparatus has isolated
transformer complies with
clause 14.3.
transformer complies with
clause 14.3.
P
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
No such components
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
No such capacitors.
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
No such capacitors.
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
CY91, CY92, CY93 and CY94
capacitors, bridging reinforced
insulation in the apparatus.
capacitors, bridging reinforced
insulation in the apparatus.
P
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm):
No such components
N/A
Reinforced insulation > 0,4 mm (mm) …….:
a. Transformers bobbin.
ref.
ref.
14.3.
b. Optocouplers inner
insulation, ref. 14.11.
insulation, ref. 14.11.
.
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
Insulation in TF91 and
TF92 transformers.
TF92 transformers.
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Page 12 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Reinforced insulation, two layers each of which meet
10.3
10.3
Thin sheet insulation used in
TF91 and TF92 transformer
between pri. and sec. winding.
(see appended table 14.3.3)
TF91 and TF92 transformer
between pri. and sec. winding.
(see appended table 14.3.3)
P
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Thin sheet insulation used in
TF91 and TF92 transformer
between pri. and iron core (ic).
(see appended table 14.3.3)
TF91 and TF92 transformer
between pri. and iron core (ic).
(see appended table 14.3.3)
P
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
No primary wiring
N/A
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
Single insulation, but safely
anchored.
anchored.
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
No primary wiring
N/A
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Single insulation, but safely
anchored.
anchored.
N/A
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No Primary wires used.
N/A
Vibration test carried out…………………………:
See 12.12
N/A
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
Adequately fastened.
P
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
Covers adequately
fastened with screws.
fastened with screws.
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
Wires safely anchored away
from parts with high
temperature.
from parts with high
temperature.
P
8.16
Only special supply equipment can be used
Not supplied by a special
supply apparatus.
supply apparatus.
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
No such winding wire
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
See below
P
8.19.1
Disconnect device
Mains plug is used as
disconnect devices.
disconnect devices.
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
No all-pole switch or circuit
breaker.
breaker.
N/A