Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
5.2 
Earth terminal  
Class II apparatus. 
N/A 
 
Hazardous live terminals  
No hazardous live terminals. 
N/A
 
 
Supply output terminals (other than mains)  
No socket outlet for providing 
power to other apparatus 
N/A 
5.3 
Use of triangle with exclamation mark  
Correct symbol applied:  
-  On name plate label, and 
-  In circuit diagram. 
Further; no incorrect use of 
this symbol is found. 
5.4 
Instructions for use  
User information in the  
following language: English. 
See comments in Summary 
of Testing. 
5.4.1 
 
a) Mains powered equipment not exposed to 
dripping or splashing. Warning concerning objects 
filled with liquid, etc.  
The user manual includes 
information about danger 
concerning dripping or  
adequate instructions supplied 
splashing and objects filled  
with liquids. 
 
b) Hazardous live terminals, instructions for wiring   
No hazardous live terminals 
N/A 
 
c) Instructions for replacing lithium battery  
No battery. 
N/A 
 
d) Class I earth connection warning  
Class II apparatus 
N/A 
 
e) Instructions for multimedia system connection  
Not applicable 
N/A 
 
f) Special stability warning for attachment of the 
apparatus to the floor/wall  
No such equipment 
N/A 
 
g) Warning: battery exposure to heat  
No battery 
N/A 
 
h) Warning: protective film on CRT face  
No CRT 
N/A 
5.4.2 
a-b) Disconnect device: plug/coupler or all-pole 
mains switch location, accessibility and markings  
Plug is regarded as disconnect 
device and is readily operable.
 
 
c) Instructions for permanently connected equipment 
Not permanent connected 
equipment 
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
Information provided in user 
manual. 
 
Page 10 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
6 Hazardous 
radiation 
 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h)  
No ionizing radiation 
N/A 
 
Ionizing radiation under fault condition  
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1….:  No laser radiation 
N/A 
 
Emission limits under fault conditions …………..: 
 
N/A 
 
Heating under normal operating conditions 
 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
No fuse links operate during 
normal operating operation.  
(see appended table 7.1) 
7.1.1 
Temperature rise of accessible parts  
(see appended table 7.1) 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table 7.1) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier  
(see appended table 7.1) 
7.1.4 
Temperature rise of windings  
(see appended table 7.1) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
Appliance inlet is certified by 
IEC/EN 60320-1 
Bobbins for TF91, TF92 and 
LF91 are made of Phenolic. 
 
See appended table 7.2 for 
Coil base of LF92 line filter. 
P
 
 
Constructional requirements with regard to the protection against electric shock 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
Considered 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
Operation “By hand” not 
possible 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
No hygroscopic materials used 
N/A 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the removal 
of a cover which can be removed by hand  
No cover removable by hand. 
N/A 
 
Page 11 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
8.5 
Class I equipment  
Class II equipment
 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 
N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
No such resistors 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
No such capacitors 
N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
Class II equipment 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
Double/Reinforced insulation 
complies with requirements 
specified in clause 10 and 13. 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
The apparatus has isolated  
transformer complies with  
clause 14.3. 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
No such components 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a)  
No such capacitors. 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
No such capacitors. 
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)  
CY91, CY92, CY93 and CY94 
capacitors, bridging reinforced 
 insulation in the apparatus.
 
8.7 
This clause is void  
 
 
8.8 
Basic or supplementary insulation > 0,4 mm (mm): 
No such components 
N/A 
 
Reinforced insulation > 0,4 mm (mm) …….: 
a. Transformers bobbin. 
 ref. 
14.3. 
b. Optocouplers inner 
  insulation, ref. 14.11.
.
 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
Insulation in TF91 and 
TF92 transformers. 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 
N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 
N/A 
 
Page 12 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
Reinforced insulation, two layers each of which meet 
10.3  
Thin sheet insulation used in 
TF91 and TF92 transformer 
between pri. and sec. winding. 
(see appended table 14.3.3) 
 
Reinforced insulation, three layers any two which 
meet 10.3  
Thin sheet insulation used in 
TF91 and TF92 transformer 
between pri. and iron core (ic). 
(see appended table 14.3.3) 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
No primary wiring 
N/A 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts 
Single insulation, but safely 
anchored. 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts.  
No primary wiring 
N/A 
Double insulation between internal hazardous live 
parts and conductors connected to accessible parts. 
Single insulation, but safely 
anchored. 
N/A 
8.11 
Detaching of wires  
 
 
No undue reduction of creepages or clearance 
distances if wires become detached  
No Primary wires used. 
N/A 
 
Vibration test carried out…………………………: 
See 12.12 
N/A 
8.12 
This clause is void  
 
 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s)  
Adequately fastened. 
8.14 
Adequate fastening of covers (push/pull test 50 N for 
10 s)  
Covers adequately 
fastened with screws. 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
Wires safely anchored away 
from parts with high  
temperature. 
8.16 
Only special supply equipment can be used  
Not supplied by a special 
supply apparatus. 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
No such winding wire 
N/A 
8.18 
Endurance test as required by 8.17  
 
N/A 
8.19 
Disconnection from the mains 
See below 
8.19.1 
Disconnect device  
Mains plug is used as 
disconnect devices. 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
No all-pole switch or circuit  
breaker. 
N/A 