JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate ▷ View online
Page 25 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
17 Electrical
connections
and mechanical fixings
17.1
Torque test to table 20
P
- screws into metal: 5 times
N/A
- screws into non-metallic material: 10 times
See appended table 17.1
P
17.2
Correct introduction into female threads in non-
metallic material
metallic material
Correct introduction of the
screws into female threads.
screws into female threads.
P
17.3
Cover fixing screws: captive
Captivity not necessary
P
Non-captive fixing screws: no hazard when replaced
by a screw whose length is 10 times its diameter
by a screw whose length is 10 times its diameter
Tested with screw with
10 times diameter.
10 times diameter.
P
17.4
No loosening of conductive parts carrying a current
> 0,2 A
> 0,2 A
Loosening is sufficiently
prevented
prevented
P
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a current
> 0,2 A
other than ceramic for connections carrying a current
> 0,2 A
No contact pressure transmitted
through insulating material.
through insulating material.
P
17.6
Stranded conductors of flexible supply cords carrying
a current > 0,2 A with screw terminals not
consolidated by solder
a current > 0,2 A with screw terminals not
consolidated by solder
Appliance inlet provided
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
No cover fixing devices
other than screws
other than screws
N/A
17.8
Fixing devices for detachable legs or stands
provided
provided
No detachable provided
N/A
17.9
Connections complies,
checked by inspection
checked by inspection
P
18
Mechanical strength of picture tubes and protection against the effects of
implosion
implosion
Picture tube separately approved to IEC 61965….:
No CRT in the equipment.
N/A
Picture tube separately approved to 18.1 ..…….:
N/A
18.1
Picture tubes >16 cm intrinsically protected
N/A
Non-intrinsically protected tubes >16 cm used with
protective screen
protective screen
N/A
Protective film as part of implosion protection: edges
covered by enclosure
covered by enclosure
N/A
18.2
Intrinsically protected tubes: tests on 12 samples
N/A
18.2.1
Samples subject to ageing: 6 samples
N/A
Page 26 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
18.2.2
Samples subject to implosion test: 6 samples
N/A
18.2.3
Samples subject to mechanical strength test (steel
ball): 6 samples
ball): 6 samples
N/A
18.3
Non-intrinsically protected tubes tested to 18.3
N/A
19
Stability and mechanical hazards
Mass of the equipment exceeding 7 kg .:
Weight: 4.1 kg
Apparatus intended to be fastened in
place – suitable instructions …………….….:
place – suitable instructions …………….….:
No
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
N/A
19.2
100 N force applied vertically downwards
N/A
19.3
100 N force, or 13% of weight, applied horizontally to
point of least stability
point of least stability
< 25 kg, < 1M
N/A
19.4
Edges or corners not hazardous
There is no hazardous edges
or corners when the apparatus
is operating in normal position
or corners when the apparatus
is operating in normal position
P
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension > 450 mm,
pass the test of 19.5.1
exceeding 0,1 m² or maximum dimension > 450 mm,
pass the test of 19.5.1
No glass surface.
N/A
19.6
Wall or ceiling mountings adequate
Not intended for wall or ceiling
mounting
mounting
N/A
20
Resistance to fire
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1
20.1
PCB is of flammability class
V-1 or better, and exception
is made for small components.
V-1 or better, and exception
is made for small components.
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4
Electrical components comply
with flammability requirements
in clause 14.
with flammability requirements
in clause 14.
N/A
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
No wires working at
voltages > 4kV or leaving
an internal fire enclosure
voltages > 4kV or leaving
an internal fire enclosure
N/A
Page 27 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC60707, unless used in a fire enclosure
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC60707, unless used in a fire enclosure
All PCB is of base material
with flammability category
V-1 or batter.
See appended table, list of
critical components
with flammability category
V-1 or batter.
See appended table, list of
critical components
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
No voltage exceeding 400V
(peak) a.c. or d.c.
(peak) a.c. or d.c.
N/A
20.1.4
Components and parts not covered by 20.1.1, 20.1.2
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the
distances in Table 21 comply with the relevant
flammability category in Table 21
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the
distances in Table 21 comply with the relevant
flammability category in Table 21
Bobbin of transformers, rated
V-0.
V-0.
P
Components and parts as above but shielded from a
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
No such components
N/A
Apparatus with voltages >4kV under normal
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
Normal operating voltage
4KV
N/A
20.2
Fire enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
No voltages exceeding 4kV,
no fire enclosure requirement
no fire enclosure requirement
N/A
20.2.2
No internal fire enclosure.
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
No internal fire enclosures
N/A
Page 28 of 42
Report No.: 171153
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
A
Annex A, Additional requirements for apparatus with protection against
splashing water
splashing water
A.5
Marking and instructions
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
Not intended for outdoor use
N/A
A.10 Insulation
requirements
N/A
A.10.2
Splash and humidity treatment
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2 Humidity
treatment carried out for 7 days
N/A
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
No TNV circuits
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
Click on the first or last page to see other ON BEAT XTREME (serv.man8) service manuals if exist.