DOWNLOAD JBL ON BEAT XTREME (serv.man8) Service Manual ↓ Size: 2.54 MB | Pages: 126 in PDF or view online for FREE

Model
ON BEAT XTREME (serv.man8)
Pages
126
Size
2.54 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-beat-xtreme-sm8.pdf
Date

JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate ▷ View online

 
Page 25 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
17 Electrical 
connections 
and mechanical fixings 
 
17.1 
Torque test to table 20  
 
 
- screws into metal: 5 times 
 
N/A 
 
- screws into non-metallic material: 10 times  
See appended table 17.1 
17.2 
Correct introduction into female threads in non-
metallic material  
Correct introduction of the  
screws into female threads.
 
17.3 
Cover fixing screws: captive  
Captivity not necessary 
 
Non-captive fixing screws: no hazard when replaced 
by a screw whose length is 10 times its diameter  
Tested with screw with  
10 times diameter. 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A  
Loosening is sufficiently 
prevented 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a current 
> 0,2 A  
No contact pressure transmitted 
through insulating material. 
17.6 
Stranded conductors of flexible supply cords carrying 
a current > 0,2 A with screw terminals not 
consolidated by solder  
Appliance inlet provided 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous  
No cover fixing devices  
other than screws 
N/A 
17.8 
Fixing devices for detachable legs or stands  
provided  
No detachable provided 
N/A 
17.9 
Connections complies,  
checked by inspection 
 
18 
Mechanical strength of picture tubes and protection against the effects of 
implosion 
 
 
Picture tube separately approved to IEC 61965….: 
No CRT in the equipment. 
N/A 
 
Picture tube separately approved to 18.1 ..…….: 
 
N/A 
18.1 
Picture tubes >16 cm intrinsically protected  
 
N/A 
 
Non-intrinsically protected tubes >16 cm used with 
protective screen  
 
N/A 
 
Protective film as part of implosion protection: edges 
covered by enclosure  
 
N/A 
18.2 
Intrinsically protected tubes: tests on 12 samples  
 
N/A 
18.2.1 
Samples subject to ageing: 6 samples  
 
N/A 
 
Page 26 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
18.2.2 
Samples subject to implosion test: 6 samples  
 
N/A 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 samples  
 
N/A 
18.3 
Non-intrinsically protected tubes tested to 18.3  
 
N/A 
 
19 
Stability and mechanical hazards 
 
 
Mass of the equipment exceeding 7 kg .: 
Weight:  4.1 kg 
 
 
Apparatus intended to be fastened in  
place – suitable instructions …………….….: 
No 
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal  
 N/A 
19.2 
100 N force applied vertically downwards  
 N/A 
19.3 
100 N force, or 13% of weight, applied horizontally to 
point of least stability  
< 25 kg, < 1M 
N/A 
19.4 
Edges or corners not hazardous  
There is no hazardous edges 
or corners when the apparatus 
is operating in normal position 
19.5 
Glass surfaces (exc.laminated) with an area 
exceeding 0,1 m² or maximum dimension > 450 mm, 
pass the test of 19.5.1  
No glass surface. 
N/A 
19.6 
Wall or ceiling mountings adequate  
Not intended for wall or ceiling 
mounting 
N/A 
 
20 
Resistance to fire 
 
20.1 
Electrical components and mechanical parts  
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width  
 N/A 
 
b) Exemption for small components as defined in 
20.1  
PCB is of flammability class  
V-1 or better, and exception  
is made for small components. 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4  
Electrical components comply 
with flammability requirements 
in clause 14. 
N/A 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, or 
located within the areas mentioned in Table 21, not 
contributing to the spread of fire  
No wires working at  
voltages > 4kV or leaving 
an internal fire enclosure 
N/A 
 
Page 27 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC60707, unless used in a fire enclosure  
All PCB is of base material 
with flammability category 
V-1 or batter.  
See appended table, list of 
critical components 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707  
No voltage exceeding 400V 
(peak) a.c. or d.c. 
N/A 
20.1.4 
Components and parts not covered by 20.1.1, 20.1.2 
and 20.1.3 (other than fire enclosures) mounted 
nearer to a potential ignition source than the 
distances in Table 21 comply with the relevant 
flammability category in Table 21  
Bobbin of transformers, rated 
V-0. 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13  
No such components 
N/A 
 
Apparatus with voltages >4kV under normal 
operating conditions and distances to the enclosure 
exceed those specified Table 21, flammability 
classification HB40 or better is required for the 
enclosure  
Normal operating voltage 
 4KV  
N/A 
20.2 
Fire enclosure  
 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1  
No voltages exceeding 4kV,  
no fire enclosure requirement 
N/A 
20.2.2 
No internal fire enclosure. 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure  
No internal fire enclosures 
N/A 
 
 
Page 28 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
Annex A, Additional requirements for apparatus with protection against 
splashing water 
 
A.5 
Marking and instructions 
 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply  
Not intended for outdoor use 
N/A 
A.10 Insulation 
requirements 
 
N/A 
A.10.2 
Splash and humidity treatment 
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water  
 
N/A 
A.10.2.2 Humidity 
treatment carried out for 7 days  
 
N/A 
 
Annex B, Apparatus to be connected to the TELECOMMUNICATION NETWORKS 
 
 
Complies with IEC 62151 clause 1  
No TNV circuits 
N/A 
 
Complies with IEC 62151 clause 2  
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard  
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard  
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this  
standard  
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C  
 
N/A 
 
Page of 126
Display