Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
Conductive parts along reliably cemented joints 
comply with 8.8  
 
N/A 
 
Temperature cycle test and dielectric strength test  
 N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts not 
conductively connected to the mains, clearances and 
creepage distances as in table 12  
No enclosed, enveloped or 
hermetically sealed parts 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8  
No parts filled with insulating  
compound. 
N/A 
 
14 Components 
 
14.1 Resistors 
 
 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts  
No such resistors 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
Bleeder resistor (R926)  
connected between Line and  
Neutral, located after fuse.  
S-c of R926 resistor does not 
cause infringement of the  
requirement for operation under
fault conditions.  
(Refer also to appended table,  
fault condition tests and list of 
critical components). 
N/A 
 
Resistors separately approved ………….: 
 
N/A
 
14.2 
Capacitors and RC units  
 
 
Capacitors separately approved …...……: 
Yes, see below 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition : 
Capacitor CY91, CY92, CY93 
and CY94, certified according  
to IEC 60384-14. 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition : 
Capacitor CX91 and CX92, 
certified according to  
IEC 60384-14. 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 …………: 
No such capacitors 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC60384-1, 4.38 category B or better ………: 
a) X-capacitor CX91, volume 
    exceeding 1750 mm³, but 
    tested to IEC384-14. 
  
b) Several E. cap. Volume 
    exceeding 1750 mm³  
    but metal cases. 
N/A 
 
Page 18 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 4.38 
category B or better ………………………: 
a) X-capacitor CX91, volume 
    exceeding 1750 mm³, but 
    tested to IEC384-14. 
  
b) Several E. cap. Volume 
    exceeding 1750 mm³  
    but metal cases. 
N/A 
 
Shielded by a barrier acc. to 20.1.4/ table 21 or 
metal …………………………………….: 
 N/A 
14.3 
Inductors and windings  
 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4  
Transformers evaluated  
according to 14.3.3, 14.3.4 
and 14.3.5 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ……………….: 
Adequate marking applied. 
Mfr, ID and type no. 
 
Transformers and inductors separately approved ….:
No. 
N/A 
14.3.2 General 
 
Isolating transformers 
 
Insulation material complies with clause 20.1.4  
Considered. The insulation 
material of isolating transf. 
complies with flammability 
category of Table 21. 
14.3.3 
Constructional requirements  
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13  
(see appended table 13) 
14.3.3.2 
Transformers meet the constructional requirements 
(see appended table 13) 
14.3.4 
Separation between windings 
 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) …………...: 
Reinforced insulation between 
pr. and sec. windings according 
to clause 8.8. 
(see appended table 14.3.3) 
 
Coil formers and partition walls > 0,4 mm  
> 0.4 mm. 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met  
Class II apparatus.  
No such transformer used. 
N/A 
14.3.4.3 
Separating transformers with at least basic insulation
Windings of Class II 
construction used. 
N/A 
14.3.5 
Insulation between HAZARDOUS LIVE parts and 
ACCESSIBLE parts 
 
 
Page 19 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)  
Double or reinforced insulation 
between hazardous live  
windings and accessible  
conductive parts. 
 
Coil formers and partition walls > 0,4 mm  
> 0.4 mm. 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal  
Winding of Class II  
construction used. 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity  
 
N/A 
14.4 
High voltage components  
No high-voltage components. 
N/A 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved  
 
N/A 
 
Component meets category V-1 of IEC 60707  
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission  
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission  
 
N/A 
14.5 
Protective devices  
 
 
Protective devices used within their ratings  
Mains fuse, F901
 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened  
Certified fuses used.  
14.5.1.1 
a) Thermal cut-outs separately approved  
No thermal cut-outs. 
N/A 
 
b) Thermal cut-outs tested as part of the submission
 
N/A 
14.5.1.2 
a) Thermal links separately approved  
No thermal links
 
N/A 
 
b) Thermal links tested as part of the submission  
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering  
No thermal device 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127  
Fuse is approved according 
to IEC 60127. 
See appended table, list of 
critical components. 
14.5.2.2 
Correct marking of fuse-links adjacent to 
holder ……: 
The following marking applied; 
F901: T 4A H 250V 
 
Page 20 of 42
 
Report No.: 171153
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
14.5.2.3 
Not possible to connect fuses in parallel …….: 
No possible to connect fuses 
in parallel. 
N/A 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool …..: 
No replacement of fuse 
possible by hand. 
14.5.3 
PTC thermistors comply with IEC 60730-1  
No PTC’s thermistors. 
N/A 
 
PTC devices (15 W) category V-1 or better  
 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked  
Only standard fuses used.
 
N/A 
14.6 Switches 
 
 
N/A 
14.6.1 a) 
Separate testing to IEC 61058 including: 
- 10 000 operations 
- Normal pollution suitability 
- Resistance to heat and fire level 3 
- Make and break speed independent of speed of 
  actuation 
V-0 compliance with annex G, G.1.1  
No mains switch. 
N/A 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage  
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1  
 N/A 
 
Switch controlling > 0.2A with open contact  voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0 
in annex G, G.1.1  
 N/A 
 
Switch controlling < 0.2A with open contact  voltage  
> 35 V (peak)/24 V dc complying with  14.6.4 and V-
0 in annex G, G.1.1  
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking  action 
independent of speed of actuation  
 
N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use  
 
N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength  
 
N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1  
 
N/A 
 
Socket outlet current marking correct  
No mains socket outlet 
N/A 