DOWNLOAD JBL ON BEAT XTREME (serv.man8) Service Manual ↓ Size: 2.54 MB | Pages: 126 in PDF or view online for FREE

Model
ON BEAT XTREME (serv.man8)
Pages
126
Size
2.54 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
on-beat-xtreme-sm8.pdf
Date

JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate ▷ View online

 
Page 4 of 12
 
Report No.: 171153
 
 
 
 
 
 
 
ATTACHMENT 7 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
8.5 Addition: 
In the first paragraph, add “and Class 0I 
Equipment” after the words, Class I Equipment. 
Class II apparatus 
N/A 
8.5 Addition: 
In the six paragraph (before NOTE 3), add the 
following to the end of the first sentence. 
CLASS 0I EQUIPMENT shall be provided with a 
protective earthing terminal in the external where 
easily visible or a protective external earth wire 
from mains plug. 
Class II apparatus 
N/A 
8.11 
Addition: 
In NOTE 2, c), add “or JIS C 2107, JIS C 2336, JIS 
C 2338” after the reference, IEC 60454. 
Noted 
N/A 
9.1.1.1 Addition: 
In the last paragraph, add the following sentence 
after the first sentence. 
For CLASS 0I EQUIPMENT, the r.m.s. TOUCH-
CURRENT to earth shall not be more than 1.0 mA.
Class II apparatus 
N/A 
10 Replacement: 
In NOTE, replace “IEC 60664-1 and IEC 60664-4 
[9]” by “JIS C 0664:2003 and IEC/TR3 60664-4 [8]”
 
 
10.1 Addition: 
Add “CLASS 0I EQUIPMENT and” to the head of 
the first paragraph. 
 
N/A 
10.3.2
 
Addition: 
In Table 5, add the following values to the sub-
table of NOTE. 
Covered 
  Operating Voltage 
(peak) 
Test voltage (peak) 
 
Curve A 
Curve B 
142 V 
1 414 V 
2 828 V 
 
11.2.1 Addition: 
Add the following after the original NOTE. 
NOTE 2  The fuse except operating characteristics 
specified in IEC 60127 shall be tested in 
consideration of the characteristic. 
IEC fuse only 
N/A 
 
Page 5 of 12
 
Report No.: 171153
 
 
 
 
 
 
 
ATTACHMENT 7 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
11.2.3 Addition: 
Add “and CLASS 0I” after the words, CLASS I. 
Class II apparatus 
N/A 
13.4 Replacement: 
In NOTE 2 of Table 11, replace IEC 60664-1 by 
JIS C 0664:2003 (corresponding to IEC 60664-1). 
Not applicable 
N/A 
14.3.3.2 Addition: 
In the second sentence of the first paragraph, add 
“or JIS C 2107, JIS C 2336 and JIS C 2338” after 
the reference, IEC 60454. 
 
N/A 
14.5.1.1 Addition: 
In item a), add “JIS C 9730 series or” before the 
reference, IEC 60730 series. 
No such components 
N/A 
14.5.1.2 Addition: 
In item a), replace IEC 60691 by “IEC 60691 or JIS 
C 6691:2003”. 
No thermal link 
N/A 
 
Addition: 
In the first paragraph of item a), add “or Appendix 3 
of the Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance and 
Material” after the reference” to the last of the 
sentence. 
 
N/A 
14.5.2.1 Replacement: 
Replace IEC 60127 by “IEC 60127 or JIS C 6575 ”.
IEC fuse
 
N/A 
14.5.2.1 Addition: 
In the first paragraph, add “Appendix 3 of the 
Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance and 
Material (limited to Fuses with the rated current of 
1 A or more), or” after the words, ”shall comply 
with”. 
 
N/A 
14.5.2.2 Addition: 
Add the following paragraph before the last 
paragraph. 
For Fuses according to Appendix 3 of the 
Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance and 
Material, only the rated current needs to be 
marked. 
IEC fuse
 
N/A 
 
Page 6 of 12
 
Report No.: 171153
 
 
 
 
 
 
 
ATTACHMENT 7 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
14.5.3 Replacement: 
Replace IEC 60730-1 by JIS C 9730-1 
(corresponding to IEC 60730-1). 
No PTC’s thermistors. 
N/A 
14.5.4 Replacement: 
Replace IEC 60127 by “IEC 60127 or JIS C 6575 ”.
Only standard fuse used. 
N/A 
14.6.1 Addition: 
Add the following paragraph after NOTE. 
The following manually operated mechanical 
switches shall meet the requirements specified in 
item a) or b) below. 
-  the controlling current exceeds 0.2 A r.m.s a.c. or 
d.c. 
-  the voltage across the open switch contacts 
exceeds 35 Vpeak ac or 24 Vdc.   
No such switch 
N/A 
14.6.1 Replacement: 
In item a), replace IEC 61058-1 by “IEC 61058-1 or 
JIS C 4526-1:1999”. 
 
N/A 
14.6.2 Replacement: 
Replace IEC 61058-1 by “IEC 61058-1 or JIS C 
4526-1:1999”. 
 
N/A 
14.6.3 Replacement: 
Replace IEC 61058-1 by “ IEC 61058-1 or JIS C 
4526-1:1999”. 
 
N/A 
14.6.5 Replacement: 
Replace IEC 61058-1 by “ IEC 61058-1 or JIS C 
4526-1:1999”. 
 
N/A 
14.7 Replacement: 
Replace IEC 60950 by JIS C 6950:2006. 
No safety interlocks. 
N/A 
 
Page 7 of 12
 
Report No.: 171153
 
 
 
 
 
 
 
ATTACHMENT 7 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065J 
15.1.1 
Replacement: 
Replace the first and second paragraph by the 
following. 
Plugs and appliance couplers for the connection of 
the apparatus to the MAINS and socket-outlets and 
interconnection couplers shall comply with the 
relevant JIS standards. If there is no appropriate 
JIS standard, they shall comply with the relevant 
IEC standards. 
Appliance connectors, interconnection outlets and 
interconnection plug-connectors compiled with 
Appendix 3 of the Ministerial Ordinance on 
stipulating technical requirements for the Electrical 
Appliance and Material are accepted. In that case, 
if due to the shape the contact parts are 
connectable to those specified in standard sheets 
of IEC 60320-1, they shall comply with dimensions 
and ratings specified in the relevant standard 
sheets of IEC 60320-1. 
Examples of relevant specifications and standards:
- Plugs / Socket-outlets: Appendix 4 of Article 1 of 
the Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance. Article 
2 (corresponding to IEC 60884) of the 
Ordinance. 
-  Appliance couplers: Appendix 4 of Article 1 of the 
Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance. Article 
2 (corresponding to IEC 60320-1) of the 
Ordinance. 
-  Appliance inlets: IEC 60320-1 
- Interconnection outlets: Appendix 4 of Article 1 of 
the Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance. IEC 
60320-2-2.  
- Interconnection couplers: Appendix 4 of Article 1 
of the Ministerial Ordinance on stipulating 
technical requirements for the Electrical 
Appliance.  
Delete NOTE 1 and NOTE 2. 
Approved cord set and  
appliance inlet provided.  
Page of 126