Report No.:  171153 
 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
14.5.1.3 Delete 
 
N/A 
14.5.2.1 
Modification: Fuse links shall comply with  
UL 248-14 
Fuses, IEC 60127. 
14.5.2.2 
Delete reference to IEC 60127 and breaking 
capacity marking requirements. 
Marked 
N/A 
14.5.3 
Add: As an option, a PTC thermistor may comply 
with UL 1434.  
Delete the 3rd and 4th paragraphs. 
No PTC thermistor 
N/A 
14.5.3A 
Add: Protective devices connected to the mains 
shall have adequate breaking capacity and comply 
with UL 873, UL 1416, UL 1417 or UL 2111 as 
applicable. 
 
N/A 
14.5.4 
Reference to fuse-links is deleted. 
 
N/A 
14.6.1 
Add: “Switches and relays shall comply with UL 10
54, UL 61058-1 or UL 508 as applicable. Mains 
switch or relay shall be rated for the total current 
through the switch or relay contacts.” 
Replace remaining text with: “A rating of a mains  
switch or relay, provided on a audio apparatus  
intended for commercial use, is to be equal to or  
greater than the maximum steady state current it  
controls under normal operating conditions except 
the audio output is adjusted to 1/3 maximum  
undistorted output or at 1/3 of the manufacturer’s  
rated output power, whichever is greater.” 
14.6.2, 14.6.3 and 14.6.4 are deleted. 
No switches 
N/A 
14.6.5 
Modification: A switch or relay that controls a mains 
socket-outlet shall have a rating equal to the 
rated current consumption of the apparatus plus 
the current rating of the socket-outlet. 
 
N/A 
14.6.6 
Add: A mains switch shall comply with (a), (b) or (c)
. The contacts of a mains relay shall comply with 
(a), (b) or (d). A switch that controls a mains 
receptacle shall comply with (b) and a relay that 
controls a mains receptacle shall comply with (b)  
or (d). 
 
N/A 
14.6.6a 
Add: Switch or relay contacts to have current rating 
equal to or greater than 1.414 times the inrush 
current of the apparatus 
 
N/A 
Page 8 of 16 
 
Report No.:  171153 
 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
14.6.6b 
Add: Switch or relay to be TV rated. 
 
N/A 
14.6.6c 
Add: Switch is located on the back of apparatus an
d is not operable from a remote control. 
 
N/A 
14.6.6d 
Add: Relay is to be subjected to the endurance test.  
N/A 
14.6.6.1 
Add: Peak Inrush current test 
 
N/A 
14.6.6.2 
Add: Relay endurance test 
 
N/A 
14.6.7 
Add: Double pole switch controlling a.c. and d.c. cir
cuits shall be suitable for the application. 
 
N/A 
14.7 
Add to the end of the 2nd paragraph “…except that 
the jointed test finger to in 9.1.1 is used to 
determine accessibility (IEC 60950, 2.8.2) and  
interlock operation (IEC 60950, 2.8.3).” 
No interlock 
N/A 
14.10.6 
Add: “An apparatus intended for use with an  
external battery shall be provided with an  
overcurrent protective device in the battery-
supply circuit.” 
No battery 
N/A 
14.11 
Add: “Component power supplies and their  
optocouplers complying with the construction and 
test requirements of UL 1310, UL 1950 Third 
Edition, or UL 60950 are considered to fulfill the  
test requirements on the clause.” 
Optocouplers bridging reinforced insulation shall 
comply with requirements for double protection as 
specified in UL 1577. 4th paragraph reads:  
“External clearances and creepage distances of  
optocouplers shall comply with 13.1.” 
Optocouplers, UR 
14.12 
Replace  
“IEC 61051-2” with “UL 1449” and “IEC 60707”  
with “UL 94.” Delete all references to “IEC 60151”. 
No varistor 
N/A 
15.1.1 
Add: “Attachment plug shall have a current rating 
no less than 125% of the current drawn under 
normal operating conditions and a voltage rating 
appropriate for the rated voltage of the apparatus. 
Current rating of the attachment 
plug have > 125% of apparatus 
rated current.   
Attachment plugs for use on more than one supply 
voltage by means of a voltage selector shall be  
rated for the voltage, which the apparatus is 
intended to be connected when it is shipped from  
the factory. 
No selector 
N/A 
Page 9 of 16 
 
Report No.:  171153 
 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
Attachment plug cap shall be polarized when the 
apparatus is provided with a manually operated,  
line connected, single-pole switch; Edison-base 
lampholder; or a 15 or 20 A socket outlet.” 
Polarized plug cap. 
15.1.2 
Delete reference to “Banana” plug in the Note. 
Built-in type speaker 
N/A 
15.1.3.1 
Add: “An audio amplifier having an open-circuit 
audio output voltage not limited to 120 V that is 
permanently connected to the mains shall be  
provided with a means for connection complying  
with U.21.1.1 – U.21.1.7 and wire-binding screws 
No. 6-32 or larger complying with U.21.3.1 –
 U.21.3.5, or quick-connect terminals, or leads. 
 
Quick Connect Terminal shall comply with the  
following:  
a) Male tabs firmly mounted in place,  
b) Mating female connectors shall be provided with
the apparatus,  
c) Strain Relief Test of Clause 16.5, 
d) Installation instructions shall be provided for  
assembly of terminal to conductor and strain relief, 
e) Terminals shall be appropriate for use with the  
size and type of wire specified.” 
No 120V audio 
N/A 
15.1.3.2 
Add: "Audio amplifiers having an audio output not  
limited to 120 V that are connected to the mains 
by a flexible cord shall have suitable cord or  
provision for field installation or a receptacle for 
plug-in connections." 
No 120V audio 
N/A 
15.2 
Add after 3rd paragraph:  
“The earthing conductor in a supply cord, or in an in
terconnecting cable shall have an equivalent or  
larger cross-sectional area that the current-carrying
conductors in the supply cord or cable.  
With reference to earthing conductors, the  
insulation color may be green or green/yellow. 
Class II apparatus 
 
N/A 
15.3.5 
Revise 2nd paragraph to read: “For rated currents 
exceeding 13 A, reference is made to Article 310 
of the National Electrical Code, ANSI/NFPA 70.” 
Table 15 - Replace with: “Nominal cross-sectional 
area AWG“ and modify values. 
Appliance inlet provided. 
N/A 
Page 10 of 16 
 
Report No.:  171153 
 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
15.4 
Add: ”Component power supply adaptors complyin
g with the construction and test requirements of UL
1310, UL 1950 Third Edition, or UL 60950 are  
considered to fulfill the test requirements on the  
clause.” 
 
N/A 
16.1 
Modification: Mains supply flexible cords shall  
comply with UL 817, be marked VW-1, and have  
an ampacity not less than the current drawn by the
apparatus. Delete references to IEC 602227, 6024

and 60173. 
Table 17A - Add: Types of cords and cord lengths 
for various types of apparatus. 
Considered 
16.2 
An integral earthing conductor shall be at least the 
same size as the other cord conductors. Substitute
“IEC 60950, table 3B” with “Article 400 of the  
National Electrical Code”. 
Table 18 – Replace with “Wire sizes of external  
flexible cords” Upper current limit in column 1  
increased from 16 to 30 A and “AWG” wire sizes  
added. 
Class II apparatus 
N/A 
16.3 
Add: c) Flexible cords not complying with 16.1, use
d as connection between the apparatus and other a
pparatus used in combination with it, shall be mark
ed VW-1. 
 
N/A 
17.8 
Expanded to include all cart/stand parts supplied by
the manufacturer, such as casters and brackets. 
Suitable assembly instructions required.  
Add: "Relevant fixing means are not required when 
installation is to be done by a skilled person." 
No accessory 
N/A 
17.10 
Add: Aluminum conductors used as internal wiring 
shall be terminated by a method capable of being 
used in the combination of metals involved at the c
onnection point. 
 
N/A 
17.11 
Add: An accessory shall be investigated to 
determine that: a) The accessory, and the combinat
ion of the accessory and the apparatus shall prese
nt no hazard in the sense of this standard and b) T
he accessory is provided with installation instructio
ns. 
 
N/A 