Page 3 of 16
Report No.: 171153
ATTACHMENT 5
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
5.4
Add: Important Safety Instructions are to be packed
with each apparatus and shall be verbatim.
with each apparatus and shall be verbatim.
Packed with apparatus.
P
5.4.1
Add: Warning about Outdoor Use is required.
In manual
P
5.4.3
Add: When apparatus contains instructions for use
by service personnel the instructions are separate
in format and preceded by a precautionary warning
statement.
by service personnel the instructions are separate
in format and preceded by a precautionary warning
statement.
No service instructions.
N/A
6.1
Starting from second paragraph replace all by:
"Compliance is checked in accordance with the
requirements in the U.S. Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, and 1020.10 by
measuring the radiation produced by the apparatus
employing a design center chassis."
"Compliance is checked in accordance with the
requirements in the U.S. Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, and 1020.10 by
measuring the radiation produced by the apparatus
employing a design center chassis."
No CRT
N/A
6.2
Starting from second paragraph replace all by: "Ap
paratus shall be classified and labeled in accordanc
e with the Code of Federal Regulations, Title 21, C
hapter 1, Subchapter J, Sections 1010.2, 1010.3, 1
040.10 and 1040.11."
paratus shall be classified and labeled in accordanc
e with the Code of Federal Regulations, Title 21, C
hapter 1, Subchapter J, Sections 1010.2, 1010.3, 1
040.10 and 1040.11."
No laser
N/A
6.2.2
Deleted
—
7.1
Table 3: Temperature limits added for various
classes of insulation systems.
Add to Note a): "Materials rated in accordance with
UL 746B may be used at their rated higher
temperature."
classes of insulation systems.
Add to Note a): "Materials rated in accordance with
UL 746B may be used at their rated higher
temperature."
Transformer Class 105
°C.
P
7.2
Add: A material temperature
rating can be accepted in lieu of the softening
temperature. The softening test need not be
performed on materials used in UL Listed or
Recognized parts.
rating can be accepted in lieu of the softening
temperature. The softening test need not be
performed on materials used in UL Listed or
Recognized parts.
Considered
P
8.1
Add: “A metal part that is not inherently resistant to
corrosion shall be protected against corrosion when
corrosion of that part is capable of contributing to or
resulting in a risk of fire, shock, or injury to
persons.”
corrosion shall be protected against corrosion when
corrosion of that part is capable of contributing to or
resulting in a risk of fire, shock, or injury to
persons.”
Chassis plated.
P
8.9.1
Add: “Sleeving, tape, tubing, and wire insulation are
suitable for the conditions of use, such as voltage
and temperature, and comply with UL 224, UL 510,
and UL 1441, as applicable.”
suitable for the conditions of use, such as voltage
and temperature, and comply with UL 224, UL 510,
and UL 1441, as applicable.”
Tape CSA/UL
P
Page 4 of 16
Report No.: 171153
ATTACHMENT 5
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
8.10
Add: “Component power supplies and their internal
insulation complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the test
requirements on the clause.”
insulation complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the test
requirements on the clause.”
N/A
8.12
Modification: Conductors and internal wiring
connecting mains socket-outlets shall comply with
the wire size requirements in clause 16.2 based on
the marked rating of the outlet but shall not be less
than 18 AWG.
connecting mains socket-outlets shall comply with
the wire size requirements in clause 16.2 based on
the marked rating of the outlet but shall not be less
than 18 AWG.
No mains socket-outlet
N/A
8.17
Add: As an option, winding wire insulation may
comply with the requirements in UL Subject 2353.
comply with the requirements in UL Subject 2353.
P
8.19.1
Modification: An all-pole switch or circuit breaker is
not required to have contact separation of 3 mm.
not required to have contact separation of 3 mm.
No all-pole switch or circuit
breaker.
breaker.
N/A
8.22
Add: “Printed wiring boards involved with the risk of
electric shock shall comply with the requirements
in UL 796.”
electric shock shall comply with the requirements
in UL 796.”
Mains pcb UL 796.
P
9.1.1.1
Replace: For Class I apparatus the r.m.s. TOUCH-
CURRENT to earth shall not be more than 3.5 MIU.
CURRENT to earth shall not be more than 3.5 MIU.
Class II apparatus
N/A
9.1.1.1a
2nd dash replaced by: “For audio signals of
professional and commercial apparatus, 120 V
r.m.s.” 3rd dash replaced by: “For audio signals
other than professional and commercial apparatus,
71 V r.m.s.”
professional and commercial apparatus, 120 V
r.m.s.” 3rd dash replaced by: “For audio signals
other than professional and commercial apparatus,
71 V r.m.s.”
Built-in type speaker
N/A
9.1.1.1b
Modification: Touch current shall comply with the A
merican National Standard for Leakage Current
for Appliances, ANSI C101 and not exceed 0.5 MIU
for Class ll Delete Note 2.
merican National Standard for Leakage Current
for Appliances, ANSI C101 and not exceed 0.5 MIU
for Class ll Delete Note 2.
Covered
P
9.1.1.2
UL articulated finger replaces IEC 61032 test
probe B. Delete 3rd paragraph.
probe B. Delete 3rd paragraph.
Covered
P
10.3
Table 5 - Add Note 1: “With respect to mains
voltages in the range of 105-130 V (r.m.s.), the test
voltages are considered to be 1414 V peak for
basic and supplementary insulation and 2828 V
peak for reinforced insulation.”
voltages in the range of 105-130 V (r.m.s.), the test
voltages are considered to be 1414 V peak for
basic and supplementary insulation and 2828 V
peak for reinforced insulation.”
Covered
P
11
Add: “Component power supplies and their power tr
ansformers complying with the construction and tes
t requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
ansformers complying with the construction and tes
t requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
N/A
Page 5 of 16
Report No.: 171153
ATTACHMENT 5
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
11.1
Modification: The permissible touch current for
terminal contacts has been increased to twice the
value given in 9.1.1.1.
terminal contacts has been increased to twice the
value given in 9.1.1.1.
N/A
11.2.1
Modification: Additional fuse testing not required
if the temperature is limited by fuses.
if the temperature is limited by fuses.
N/A
12
Add: “Component power supply adaptors and their
enclosures complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the test
requirements on the clause.
enclosures complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the test
requirements on the clause.
N/A
12.1.3
Delete the first two paragraphs. Impact test uses
the 50mm steel sphere only.
Table 6 – Replace title with “Apparatus impact test.”
Table 6 modified to provide impact test criteria
detailing impact location, impact energy and
additional pass/fail results.”
the 50mm steel sphere only.
Table 6 – Replace title with “Apparatus impact test.”
Table 6 modified to provide impact test criteria
detailing impact location, impact energy and
additional pass/fail results.”
Considered
P
12.1.4
Add to the end of the 1st paragraph: “As an
alternative, any number form one to three samples
are permitted to be used in any combination that
results in a total of three drops.”
alternative, any number form one to three samples
are permitted to be used in any combination that
results in a total of three drops.”
No damaged
P
12.1.6
Add: Handle strength test requirements.
Hadle tested.
P
12.7
Add: Wall and ceiling mounting means test require
ments.
ments.
N/A
12.8
Add test for enclosures, barriers, components and
leads that rely on adhesive.
leads that rely on adhesive.
N/A
12.8.1
Add test for conductive labels secured in place by
adhesive.
adhesive.
No conductive labels
N/A
13
Add: ”Component power supplies and their power
transformers complying with the construction and
test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
transformers complying with the construction and
test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.”
N/A
13.4
Modification: A material group is verified according
to UL 746A.
to UL 746A.
13.5.1
Change standard reference from IEC 60249-2 to
UL 796.
UL 796.
Page 6 of 16
Report No.: 171153
ATTACHMENT 5
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
13.5.2
Modification: Coated printed wiring boards shall
comply with requirements in UL 746C
comply with requirements in UL 746C
No coated printed wiring boards
N/A
13.7
Table 12 - Note 3 revised to refer to UL 746A.
No enclosed and sealed parts
N/A
14
Delete Note 2. Add reference to Annex Y and
additional component requirements.
additional component requirements.
14.1, 14.2
and 14.3
and 14.3
Add: ”Component power supplies and their
resistors complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the test
requirements of Clause 14.1 and 14.2.1 – 14.5.2..”
resistors complying with the construction and test
requirements of UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the test
requirements of Clause 14.1 and 14.2.1 – 14.5.2..”
N/A
14.2.1 and
14.2.2
14.2.2
Add: “As an alternative a component such as a cap
acitor, a combination capacitor and resistor, a
varistor, or a suppressor shall comply with the
requirements for Across-the Line, Antenna-
Coupling, or Double Protection in UL 1414.”
acitor, a combination capacitor and resistor, a
varistor, or a suppressor shall comply with the
requirements for Across-the Line, Antenna-
Coupling, or Double Protection in UL 1414.”
Cap. 384-14
N/A
14.2.4
Replace text with: “Components subjected to the re
quirements in 14.2.1 and 14.2.2 shall also comply
with the enclosure requirements of UL 1414.”
quirements in 14.2.1 and 14.2.2 shall also comply
with the enclosure requirements of UL 1414.”
Cap. UR
P
14.4
Add to Note 2: “High voltage materials shall be
rated 94V-2 minimum.”
Modification: Compliance is checked by meeting
requirements for category V-2 according to UL 94.
Moreover the requirements are added for arcing,
component part flame and high-voltage isolating
component tests.
rated 94V-2 minimum.”
Modification: Compliance is checked by meeting
requirements for category V-2 according to UL 94.
Moreover the requirements are added for arcing,
component part flame and high-voltage isolating
component tests.
No High voltage
N/A
14.4.1
Replace with High voltage arcing test.
N/A
14.4.2 Deleted.
N/A
14.4.3
Add: High voltage component part flame test.
N/A
14.4.4
Add: High voltage isolation component insulation
test.
test.
N/A
14.5.1
Delete reference to 14.5.1.3.
N/A
14.5.1.1
Replace text with: Thermal cutouts shall comply
with UL 873, UL 8730-2-9 or UL 60730-2-9.
with UL 873, UL 8730-2-9 or UL 60730-2-9.
No thermal cutout.
N/A
14.5.1.2
Replace text with: "Thermal links shall comply with
UL 1020 or IEC 60691."
UL 1020 or IEC 60691."
No thermal links
N/A