JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate ▷ View online

Page 11 of 16 
 
Report No.:  171153 
 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
17.11.1 
Add: The installation of an accessory of a skilled 
person shall be such that: a) The mechanical 
positioning is accomplished by means of tools  
normally available or by means of special tools  
provided by the organization responsible for  
providing the apparatus as part of the installation 
kit, and b) The electrical connections are made by 
using existing terminals and connections in the  
apparatus or the building wiring. 
 
N/A 
18 
Modification: Non-intrinsically protected picture 
tubes shall comply with 18.1, 18.2.2 and 18.3. 
Intrinsically protected picture tubes shall comply  
with UL 1418 or UL 61965.  
Add: “A bulb of a picture tube having a face  
diameter of 7.5 cm or more shall be mounted in an 
enclosure.  
The enclosure shall have no opening that exceeds
130 mm2 unless the minor dimension of the  
opening is 10 mm or less.” 
No picture tube 
N/A 
18.1 
All tubes shall be mounted such that the enclosure
of the apparatus protects the tube against the 
effects of implosion. 
No CRT 
N/A 
18.2, 
18.2.1, and 
18.2.3 
Delete reference to clause 18.2, 18.2.1, and 
18.2.3 are deleted 
No CRT 
N/A 
19 
Add reference to 19.2.1.  
The test of 19.3 is conducted on  
1) apparatus with direct view CRT with 48 cm  
diagonal min.,  
2) apparatus, other than a speaker, with a mass  
greater than 47 kg, and  
3) apparatus, other than a speaker, with a mass 
or 25 kg or greater and a height of 1 m or more.  
The tests in 19.1, 19.2 and  19.3 shall not cause  
the apparatus to overturn.  
During the test of 19.2.1, the apparatus shall not  
slide. 
1) No CRT 
2) Apparatus, mass < 47 kg 
3) Apparatus, < 25 kg or < 1 m 
N/A 
19.2.1 
Add: Slide test requirements. 
 
N/A 
19.3 
Replace by Horizontal force stability test  
requirements. 
 
N/A 
Page 12 of 16 
 
Report No.:  171153 
 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
Table 20 
Add values for horizontal force test 
 
N/A 
19.6. 
Add: “or equipment rack mounting”. 
 
N/A 
20.1a Delete 
 
N/A 
20.1b 
Replace “IEC 60707” with “UL 94” 
Add: “-parts such as protection TV lenses,  
loudspeaker parts, external accessories, and  
fibrous materials less then 0.25 mm thick.” 
Noted 
N/A 
20.1.2 
Revise text to read: “Sleeving, extruded tubing and
insulation on wiring shall be rated VW-1 under 
following conditions:  
a) wiring located in a circuit that is considered a  
potential ignition source” or  
b) wiring not located in a circuit that is a potential  
ignition source but is in contact with wiring located 
in a circuit that is a potential ignition source.  
”Tape should be flame retardant.”  
Delete Note and add: “Tape in contact with parts  
of circuits that are potential ignition sources shall  
be flame retardant. 
Considered 
20.1.3 
Replace 1st paragraph with:  
“Base material of printed wiring boards, on which 
the available power as the connection exceeds  
15 W or the operating voltage exceeds 50 V a.c.  
or d.c under normal operating conditions, shall be 
of flammability category V-1 or better according 
to UL 94.”  
 
In 2nd paragraph replace “IEC 60707” with “UL 94”
and remove exception for printed boards housed  
in metal enclosures. 
 
In 3rd paragraph replace “IEC 60707” with “UL 94”
and delete option to use Clause G.1 of Annex G. 
Pcb V-1 
20.1.4 
Replace with: “Components and parts shall comply
with the relevant flammability category according 
to UL 94 as specified in Table 21.  
Delete all other text. 
Parts meet table 21. 
Add: “Component power supplies complying with 
the construction and test requirements of UL 1310,
UL 1950 Third Edition, or UL 60950 are considered
to fulfill the test requirements on the clause.” 
No component power supplies 
N/A 
Page 13 of 16 
 
Report No.:  171153 
 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
Table 21 - Replace complete table with new table 
for “Flammability categories for components and  
parts.” 
Considered 
20.2.1 
Modification: 1st paragraph: “Fire enclosure 
required for  
1) circuits and components where the available 
power exceeds 15 W,  
2) inductors and windings conductively connected 
to the mains and  
3) high-voltage products.  
The fire enclosure shall comply with the 
flammability 
requirements of Table 22 according to UL 94 and 
746C. 2nd, 3rd, and 4th paragraphs are deleted.  
In 5th paragraph replace “IEC 60707 or clause G.1 
of Annex G” with “UL 94 or UL 746C.”  
Table 22 – Add” Flammability categories for fire 
enclosures. 
No fire enclosure 
N/A 
20.2.2 
No internal fire enclosures 
N/A 
20.2.3 
Modification: Outer enclosures shall have a minimum 
flammability rating of HB, per UL 94,  
when an internal fire enclosure is provided. 
No internal fire enclosures 
N/A 
M
odifications 
to Figures: 
 
Fig 14 - Illustrates the articulated finger probe. 
Fig 15 - Illustrates the shock hazard marking and 
associated graphical symbols. 
Fig 16 - Illustrates the shock hazard graphical 
symbol. 
Fig 17 - Illustrates portable cart marking. 
Fig 18 - High voltage spacings graph. 
Fig 19 - Class 105 insulation aging temperature 
graph. 
Fig 20 - Flowchart for horizontal force test. 
Considered 
Page 14 of 16 
 
Report No.:  171153 
 
 
ATTACHMENT 5 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
Annex A 
Modification: Apparatus intended for outdoor use or 
wet locations has any of the following attributes:  
a) provided with a means to make it transportable,  
b) has a mass less than 35 kg,  
c) can be battery operated, d) associated literature 
states or implies such use  
 
Add: Apparatus in a), b), or c) above is not 
considered for outdoor use or in wet locations if 
marked as specified in 5.4..A.5, A.5.1 and A.5.4.1 are 
deleted. 
A.9.1.1 - Add: Touch current test shall be conducted 
after the water spray test described in A.11.1.1 and  
the touch current shall not be more than 0.5 MIU  
when the open-circuit potential between any 
accessible part and earth or any other accessible  
part is more than 21.2 V peak. 
 
A.10, A10.2, A.10.2.1, and A.10.2.2 are deleted. 
A.11.1.1 - Add: Apparatus shall be subjected to the 
water spray test according to UL 1571. 
A.16.1 - Add: Flexible cords shall be suitable for  
outdoor use. 
 
A.20.2.1 - Add: Enclosures for an apparatus 
intended for permanent outdoor location shall 
comply with requirements for Type 3 enclosures  
in UL 50. 
Apparatus is indoor use only 
N/A 