Page 3 of 11
Report No.: 171153
ATTACHMENT 6
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
3.2A
Add the following clause:
A component power supply complying with
CAN/CSA-C22.2 No. 60950 is considered to
comply with this construction and fault conditions
of this Standard after taking into account any
relevant conditions of acceptability.
CAN/CSA-C22.2 No. 60950 is considered to
comply with this construction and fault conditions
of this Standard after taking into account any
relevant conditions of acceptability.
N/A
4.2.1
Add the following after the fifth paragraph:
For apparatus intended for use at nominal 120V
ac, the apparatus shall comply with this standard
at supply voltages between 108V and 125V. For
apparatus intended for use at nominal 240V ac the
apparatus shall comply with this standard at supply
voltages between 216V and 250V.
ac, the apparatus shall comply with this standard
at supply voltages between 108V and 125V. For
apparatus intended for use at nominal 240V ac the
apparatus shall comply with this standard at supply
voltages between 216V and 250V.
Apparatus rated 100-240V,
P
4.2.10
Add the following after the second paragraph:
As an alternative, a supply apparatus for general
use complying with CSA/CSA-C22.2 No. 223 or
CAN/CSA-C22.2 No. 60950 shall be acceptable.
use complying with CSA/CSA-C22.2 No. 223 or
CAN/CSA-C22.2 No. 60950 shall be acceptable.
N/A
5
Markings and instructions – adhesive nameplates
Add the following paragraph:
Adhesive nameplates on commercial products
shall comply with CSA C22.2 No 0.15.
shall comply with CSA C22.2 No 0.15.
No commercial
N/A
5.1
Add the following item:
j) Date of manufacture: a date or code identifying
the period of manufacture shall be marked on the
apparatus;
the period of manufacture shall be marked on the
apparatus;
Marked
P
5.3A
Add the following clause:
Where a loudspeaker grille, removable from the
outside, is relied on as part of the enclosure
(see Clause 9.2), the following marking or
equivalent shall be visible on the enclosure after
removal of the grille:
outside, is relied on as part of the enclosure
(see Clause 9.2), the following marking or
equivalent shall be visible on the enclosure after
removal of the grille:
"Caution -
To prevent electric shock hazard, replace grille."
To prevent electric shock hazard, replace grille."
Alternatively, the symbol in Clause 5.2 b) shall be v
isible after removal of the grille, and the caution wo
rding above shall appear in the user instructions, a
ccompanied by the symbol.
isible after removal of the grille, and the caution wo
rding above shall appear in the user instructions, a
ccompanied by the symbol.
Compliance is checked by inspection.
Not removable
N/A
Page 4 of 11
Report No.: 171153
ATTACHMENT 6
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
8.9
Add the following title to this clause:
Mains Wiring
Add the following paragraph:
Wiring in circuits with voltages higher than 42V
peak shall comply with CSA C22.2 No 127 or
CAN/CSA C22.2 No. 210.2.
Mains Wiring
Add the following paragraph:
Wiring in circuits with voltages higher than 42V
peak shall comply with CSA C22.2 No 127 or
CAN/CSA C22.2 No. 210.2.
No mains wiring
N/A
9.1.1A
Class I Apparatus Leakage
Add the following Clause:
For cord-connected Class I apparatus, the leakage
current through the safety earthing conductor
expressed as voltages U1 and U2 shall not exceed
U
Add the following Clause:
For cord-connected Class I apparatus, the leakage
current through the safety earthing conductor
expressed as voltages U1 and U2 shall not exceed
U
1
= 105V (peak) and U
2
= 1.05V (peak) (1.5mA).
Class Il apparatus
N/A
Apparatus having a leakage current between 0.75
mA and 1.5 mA shall be provided with a caution la
bel on the mains cord with the following, or equival
ent:
"CAUTION - TO REDUCE THE RISK OF
ELECTRIC SHOCK, GROUNDING OF THE
CENTRE PIN OF THIS PLUG MUST BE
MAINTAINED".
mA and 1.5 mA shall be provided with a caution la
bel on the mains cord with the following, or equival
ent:
"CAUTION - TO REDUCE THE RISK OF
ELECTRIC SHOCK, GROUNDING OF THE
CENTRE PIN OF THIS PLUG MUST BE
MAINTAINED".
Class Il apparatus
N/A
9.1.1.2
Determination of accessible parts –
loudspeaker enclosure parts
Add the following after the fourth paragraph:
Moving parts of loudspeaker systems, such as dus
t caps or cones of drivers or passive radiators are
not regarded as preventing accessibility.
NOTE 1A: See also Clause 13.3.1
loudspeaker enclosure parts
Add the following after the fourth paragraph:
Moving parts of loudspeaker systems, such as dus
t caps or cones of drivers or passive radiators are
not regarded as preventing accessibility.
NOTE 1A: See also Clause 13.3.1
No access to hazardous
live parts.
live parts.
P
9.2
Removal of protective covers –
loudspeaker grilles
Add the following after the second paragraph:
This requirement applies also to internal parts of lo
udspeaker systems that become accessible by re
moval of a loudspeaker grille from the outside eithe
r by hand or with the use of a tool, coin, or other ob
ject. In such cases, the apparatus shall be marked
according to Clause 5.3A.
Replace the third paragraph with the following:
Compliance is checked by inspections and by
application of the tests of Clause 9.1.1, except that
the measurements are made 2s after removal of
the cover or grille.
loudspeaker grilles
Add the following after the second paragraph:
This requirement applies also to internal parts of lo
udspeaker systems that become accessible by re
moval of a loudspeaker grille from the outside eithe
r by hand or with the use of a tool, coin, or other ob
ject. In such cases, the apparatus shall be marked
according to Clause 5.3A.
Replace the third paragraph with the following:
Compliance is checked by inspections and by
application of the tests of Clause 9.1.1, except that
the measurements are made 2s after removal of
the cover or grille.
No cover removable by hand
N/A
Page 5 of 11
Report No.: 171153
ATTACHMENT 6
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
10.2A
Enclosure type designation and use –
outdoor enclosure
outdoor enclosure
Add the following clause:
If equipment is installed in environments where the
enclosure is required to prevent ingress of water or
dust, the enclosure shall be classified as a type
recognized by the Canadian Electrical Code, Part
I, and shall comply with the requirements of
CSA/CSA-C22.2 No. 94.
enclosure is required to prevent ingress of water or
dust, the enclosure shall be classified as a type
recognized by the Canadian Electrical Code, Part
I, and shall comply with the requirements of
CSA/CSA-C22.2 No. 94.
Not outdoor
N/A
11.2
Heating – flammable gases
Add the following clause:
Flammable gases shall not be emitted from a
component for more than 10 secs.
Flammable gases shall not be emitted from a
component for more than 10 secs.
No flammable gases.
P
12.3A.1
Television Impact Test: For television sets and
similar apparatus using a cathode ray tube larger
than 160mm diagonally, the top, sides, front and
rear of the enclosure, including the safety screen
where provided, shall be capable of withstanding a
single impact of 7J in accordance with Clause
12.3A.2 without developing any opening larger
than 130mm
similar apparatus using a cathode ray tube larger
than 160mm diagonally, the top, sides, front and
rear of the enclosure, including the safety screen
where provided, shall be capable of withstanding a
single impact of 7J in accordance with Clause
12.3A.2 without developing any opening larger
than 130mm
2
in the enclosure of the cathode ray
tube unless the minor dimension of any opening is
not more than 7mm.
not more than 7mm.
When applied to a safety screen, the impact shall
neither result in damage to its mounting to the
extent it is mechanically unsuitable for reuse nor
shall tempered glass, if used, be cracked.
neither result in damage to its mounting to the
extent it is mechanically unsuitable for reuse nor
shall tempered glass, if used, be cracked.
When applied to the face of a directly viewed
cathode ray tube, the impact shall not develop any
opening in the face of the tube. Scaling and
cracking of the glass is permissible. A cathode ray
tube that has been shown to comply with
CAN/CSA-C22.2 No 228 or CAN/CSA-E61965
shall be considered acceptable with no further
tests.
cathode ray tube, the impact shall not develop any
opening in the face of the tube. Scaling and
cracking of the glass is permissible. A cathode ray
tube that has been shown to comply with
CAN/CSA-C22.2 No 228 or CAN/CSA-E61965
shall be considered acceptable with no further
tests.
N/A
12.3A.2
Television Impact Object:
The impact specified in Clause 12.3A.1 shall be
caused by allowing a solid, smooth, steel sphere
51mm in diameter and weighing approximately
0.5kg to strike the enclosure with the specified
impact in a direction perpendicular to the
enclosure surface. If deemed necessary, the
enclosure shall be tested with the proper cathode
ray tube mounted.
caused by allowing a solid, smooth, steel sphere
51mm in diameter and weighing approximately
0.5kg to strike the enclosure with the specified
impact in a direction perpendicular to the
enclosure surface. If deemed necessary, the
enclosure shall be tested with the proper cathode
ray tube mounted.
N/A
Page 6 of 11
Report No.: 171153
ATTACHMENT 6
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
13.3.1
General – loudspeaker voice coil
Add the following after the third paragraph:
CLEARANCES between a loudspeaker voice coil
and adjacent conductive parts shall be
disregarded.
and adjacent conductive parts shall be
disregarded.
Considered.
P
14.2
14.2.1
Capacitors and RC-units
(Y-Capacitors)
Add the following paragraph:
Add the following paragraph:
As an alternative an isolating capacitor complying
with applicable requirements of CSA C22.2 No 1,
shall be acceptable for bridging BASIC or
SUPPLEMENTARY INSULATION.
with applicable requirements of CSA C22.2 No 1,
shall be acceptable for bridging BASIC or
SUPPLEMENTARY INSULATION.
Considered.
P
14.2.2 (X-Capacitors)
Add the following paragraph:
As an alternative an across-line capacitor
complying with applicable requirements of CSA
C22.2 No 1, shall be acceptable.
complying with applicable requirements of CSA
C22.2 No 1, shall be acceptable.
60384-14 & CSA No. 1.
complied.
complied.
P
14.5.1
14.5.1.2
Thermal releases
Add the following paragraph:
As an alternative a THERMAL LINK complying
with CSA C22.2 No 209 shall be acceptable.
with CSA C22.2 No 209 shall be acceptable.
N/A
14.5.2
14.5.2.1
Fuse-links and fuse holders
Add the following paragraph:
As an alternative, a fuse-link complying with CSA
C22.2 No 248.14 shall be acceptable.
C22.2 No 248.14 shall be acceptable.
Fuses, IEC 60127.
P
14.5.2.4
Add the following paragraph:
As an alternative a Fuseholder Assembly
complying with CSA C22.2 No 39 shall be
acceptable.
complying with CSA C22.2 No 39 shall be
acceptable.
No fuseholder.
N/A
14.6.1 to
14.6.5
14.6.5
Switches:
Add the following to each of the Clauses:
As an alternative, a TV-Rated Switch complying
with CSA C22.2 No 1-98, Cl 9 shall be acceptable.
with CSA C22.2 No 1-98, Cl 9 shall be acceptable.
No switch.
N/A
14.11
Optocouplers
Add the following paragraph:
As an alternative, an optocoupler complying with
CSA C22.2 No. 1 shall be acceptable.
CSA C22.2 No. 1 shall be acceptable.
IEC60950 &
CSA No. 1.
complied.
P