JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate ▷ View online
Page 11 of 11
Report No.: 171153
ATTACHMENT 6
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
18
18.1A
Mechanical strength of picture tubes and
protection against the effects of implosion
(Cathode Ray Tubes)
Add the following clause:
A picture tube with a maximum face dimensions
exceeding 75mm either shall be intrinsically
protected with respect to effects of implosion and
to mechanical impact, in accordance with
CAN/CSA C22.2 No 228 or CAN/CSA E61965, or
the enclosure of the apparatus shall provide
adequate protection against the effects of an
implosion of the tube (see Clause 12).
protection against the effects of implosion
(Cathode Ray Tubes)
Add the following clause:
A picture tube with a maximum face dimensions
exceeding 75mm either shall be intrinsically
protected with respect to effects of implosion and
to mechanical impact, in accordance with
CAN/CSA C22.2 No 228 or CAN/CSA E61965, or
the enclosure of the apparatus shall provide
adequate protection against the effects of an
implosion of the tube (see Clause 12).
N/A
19
Stability and Mechanical Hazards
Add the following after the second paragraph:
The test of 19.3 is only required for:
Add the following after the second paragraph:
The test of 19.3 is only required for:
a) Apparatus with a mass of 25 kg or more; or
b) Apparatus,
excluding
loudspeaker systems,
with a height of 1m or more; or
c) Apparatus, including loudspeaker systems, in
combination with a supplied or recommended
cart of stand with a total height of 1m or more.
cart of stand with a total height of 1m or more.
Mass of 4.1 Kg
N/A
Add the following paragraph:
Apparatus not tested because it is intended to be
fastened in place shall be provided with the
following warning, marked on the apparatus or on
a durable label attached to the mains cord:
“WARNING: This apparatus must be securely
attached to the floor /wall per installation
instructions. Tipping, shaking, or rocking the
machine may cause injury / death”
Apparatus not tested because it is intended to be
fastened in place shall be provided with the
following warning, marked on the apparatus or on
a durable label attached to the mains cord:
“WARNING: This apparatus must be securely
attached to the floor /wall per installation
instructions. Tipping, shaking, or rocking the
machine may cause injury / death”
N/A
20
20.2.1A
Fire enclosure
(Projector Lamp Enclosure)
Add the following clause:
Enclosures of apparatus containing high voltage or
projection lamps shall have a minimum
flammability rating of category FV1 according to
IEC 60707 at the minimum thickness used.
(Projector Lamp Enclosure)
Add the following clause:
Enclosures of apparatus containing high voltage or
projection lamps shall have a minimum
flammability rating of category FV1 according to
IEC 60707 at the minimum thickness used.
N/A
Annex B
Apparatus to be connected to the
telecommunications networks
Replace this annex with the following:
Apparatus intended for direct connection to a
TELECOMMUNICATION NETWORK shall comply
with:
a) Clause 19 of CSA C22.2 No 1; or
b) CAN/CSA C22.2 No. 60950.
telecommunications networks
Replace this annex with the following:
Apparatus intended for direct connection to a
TELECOMMUNICATION NETWORK shall comply
with:
a) Clause 19 of CSA C22.2 No 1; or
b) CAN/CSA C22.2 No. 60950.
N/A
Page 1 of 12
Report No.: 171153
ATTACHMENT 7
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
JAPAN NATIONAL DIFFERENCES
Test results according to Online CB BULLETIN (Last modification date of 2010-04-09)
Differences according ................... : IEC 60065 Ed. 7 (2005)
Corresponding National Standard J60065 (H20)
No.
Requirement – Test
Result - Remark
Verdict
1.1.3 Addition:
Add the following as a NOTE after the first
sentence.
NOTE 1 In Japan, the requirements for regions
with moderate apply.
sentence.
NOTE 1 In Japan, the requirements for regions
with moderate apply.
Moderate climate covered
P
2.4.9 Replacement:
In NOTE 1, replace “see 4.2.2 of IEC 62151” by
“see 4.2.2 of IEC 62151 [27]”.
“see 4.2.2 of IEC 62151 [27]”.
No TNV circuits.
N/A
2.6.2A Addition:
Add this sub clause.
CLASS 0I EQUIPMENT: Equipment which has, as
for protection against electric shock,
for protection against electric shock,
- at least using BASIC INSULATION, and
- providing a means of connecting to the
protective earthing conductor in the building
wiring those conductive parts that are otherwise
capable of assuming HAZARDOUS
VOLTAGES if the BASIC INSULATION fails,
and
wiring those conductive parts that are otherwise
capable of assuming HAZARDOUS
VOLTAGES if the BASIC INSULATION fails,
and
- using a supply cord without earthing conductor
and a plug without earthing wire although the
equipment has externally an earth terminal or a
lead wire for earthing.
equipment has externally an earth terminal or a
lead wire for earthing.
Equipment provided with a cord set having a two-
pin type plug with a lead wire for earthing or having
three pin - tow pin adaptor is also regarded as
Class 0I.
pin type plug with a lead wire for earthing or having
three pin - tow pin adaptor is also regarded as
Class 0I.
NOTE Class 0I equipment may have a part
constructed with Double Insulation or Reinforced
Insulation.
constructed with Double Insulation or Reinforced
Insulation.
Class II apparatus
N/A
3.2 Addition:
Add the “Class 0I equipment” in the first sentence
of this sub-clause.
of this sub-clause.
Class II apparatus
N/A
Page 2 of 12
Report No.: 171153
ATTACHMENT 7
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
3.2 Addition:
Add the following after the first sentence of this
sub-clause.
sub-clause.
NOTE Equipment often transported and used
should not be Class I equipment nor Class 0I
equipment.
should not be Class I equipment nor Class 0I
equipment.
Class II
N/A
4.2.8
Deletion:
Delete this clause.
Delete this clause.
—
4.3.4, b)
Replacement:
Replace IEC 60730-1 by JIS C 9730-1
(corresponding to IEC 60730-1).
Replace IEC 60730-1 by JIS C 9730-1
(corresponding to IEC 60730-1).
No PTC’s thermistors.
N/A
4.3.12
Deletion:
Delete this clause.
Delete this clause.
—
4.3.13 Replacement:
Replace “250 V a.c.” by “the maximum of the
variable range”.
variable range”.
No voltage setting devices
N/A
5.4.2A Addition:
For CLASS 0I EQUIPMENT, the following
instruction shall be indicated where readily visible
on the mains plug or the product:
instruction shall be indicated where readily visible
on the mains plug or the product:
“WARNING: Provide an earthing connection”
Example in Japanese:
Moreover, for CLASS 0I EQUIPMENT, the
following instruction shall be indicated where
readily visible on the product or written in the
operating instructions:
following instruction shall be indicated where
readily visible on the product or written in the
operating instructions:
“WARNING: Provide an earthing connection
before the mains plug is connected to the mains.
And, when disconnecting the earthing connection,
be sure to disconnect after pulling out the mains
plug from the mains.”
before the mains plug is connected to the mains.
And, when disconnecting the earthing connection,
be sure to disconnect after pulling out the mains
plug from the mains.”
Example in Japanese:
Class II apparatus
N/A
Page 3 of 12
Report No.: 171153
ATTACHMENT 7
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
6.2
Replacement:
In NOTE 1, replace IEC 61040 [10] by JIS C
6181:1995 [10].
6181:1995 [10].
Considered
P
7.1.5
Addition:
Add the words, “without dimensions restrictions”
after the figure, “65 K” in the first sentence of
Condition “b” in Table 3 as follows.
after the figure, “65 K” in the first sentence of
Condition “b” in Table 3 as follows.
For parts not likely to be touched during intended
use, temperature rises up to 65 K without
dimensions restrictions are allowed under normal
operating conditions.
use, temperature rises up to 65 K without
dimensions restrictions are allowed under normal
operating conditions.
Comply
P
Addition:
Add the following paragraph as 2
nd
paragraph of
Condition “d “in Table 3.
For materials which are not listed in Table 3,
temperature rises in the normal operating
conditions are considered satisfactory if these
materials comply with item 3 of detailed
regulations, 1.(1),b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements for
the Electrical Appliance and Material. Permissible
temperature rise of “Supply cords and wiring
insulation” is applicable only to the materials used
in supply cords complying with JIS C 3662
(corresponding to IEC 60227) or JIS C 3663
(corresponding to IEC 60245). Materials used in
other wiring shall comply with item 3 of detailed
regulations, 1.(1).b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements for
the Electrical Appliance and Material.
temperature rises in the normal operating
conditions are considered satisfactory if these
materials comply with item 3 of detailed
regulations, 1.(1),b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements for
the Electrical Appliance and Material. Permissible
temperature rise of “Supply cords and wiring
insulation” is applicable only to the materials used
in supply cords complying with JIS C 3662
(corresponding to IEC 60227) or JIS C 3663
(corresponding to IEC 60245). Materials used in
other wiring shall comply with item 3 of detailed
regulations, 1.(1).b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements for
the Electrical Appliance and Material.
No such materials used.
N/A
Addition:
In the first paragraph of Condition “f” of Table 3,
add ”JIS K 7206:1999 or” before the reference, ISO
306.
add ”JIS K 7206:1999 or” before the reference, ISO
306.
N/A
Addition:
In Condition “f,” 1) of Table 3, add ”JIS K
7206:1999 or” before the reference, ISO 306.
7206:1999 or” before the reference, ISO 306.
N/A
7.2 Addition:
In NOTE 2, add ”or JIS standard” after the word,
IEC standard.
IEC standard.
Noted
N/A