JBL ON BEAT XTREME (serv.man8) EMC - CB Certificate ▷ View online

Page 7 of 11 
 
Report No.: 171153  
 
 
ATTACHMENT 6 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
14.12 
Surge suppression varistors 
Add the following paragraph: 
As an alternative, a varistor complying with CSA 
C22.2 No. 1 shall be acceptable. 
No surge varistor 
N/A 
14.12A 
Gas discharge tubes 
Add New Clause 14.12A: 
Gas discharge tubes complying with the following 
tests may be connected to bridge BASIC or 
REINFORCED INSULATION.  
 
Ten samples of gas discharge tubes isolating the 
ac supply from exposed parts shall be subjected to 
the varistor pulse tests of Clause 14.12. Following 
the pulses, the device shall be allowed to return to 
room temperature. The dielectric breakdown 
voltage of the gas tube shall not decrease by more 
than 50% and the gas discharge tube shall comply 
with the electric strength test of Clause 10.3, with 
the test voltage reduced to twice the mains 
voltage. 
No gas tube 
N/A 
15.1 
15.1.1 
Plugs and sockets 
(Convenience Receptacle Type) 
Add the Following Clause: 
A receptacle provided for general purpose mains 
output shall comply with the requirements of CSA 
Standard C22.2 No 42 (dimensional requirements 
are also specified in IEC 60906-2). The attachment 
plug cap shall be polarized type when the 
apparatus is provided with a manually operated, 
MAINS connected single pole switch for apparatus 
on-off operation, a socket screwshell lampholder, 
or a 15 or 20 A socket outlet. 
No socket outlet 
N/A 
15.1.2 
(Audio Terminals
Add the following paragraph: 
Banana plugs shall be acceptable. 
No banana plugs 
N/A 
15.1.3 
Adapter output connectors 
Replace the first paragraph with the following: 
Terminals and connectors used in output circuits of 
supply apparatus, whose output is not a standard 
nominal mains voltage according to IEC 60038, 
Table 1, shall not be compatible with those 
specified for household and similar general 
purposes, for example those described in IEC 
60083[1], IEC 60320, IEC 60884, IEC 60906 (parts 
1, 2, and 3), and CSA C22.2 No 42. 
No mains output 
Page 8 of 11 
 
Report No.: 171153  
 
 
ATTACHMENT 6 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
15.2 
Provisions for protective earthing - Bond 
Impedance 
Replace the third paragraph with the following: 
Earthing connections shall comply with the test 
requirements of CSA C22.2 No 0.4. 
Class ll apparatus 
N/A 
15.3 
15.3.1A 
Terminals for external flexible cords and 
permanent connections to the mains supply
  
(Permanent Wiring) 
Add the following clauses: 
Equipment intended for permanent connection to 
the mains shall have provisions for connection to 
the wiring system in accordance with the Canadian 
Electrical Code, Part I. 
Appliance inlet applied
 
N/A 
The terminal parts and all other provisions for 
permanent connection to fixed wiring shall comply 
with CSA Standard CAN/CSA-C22.2 No 0. 
Apparatus is not for 
permanent connection.
 
N/A 
15.4.2 
(Mains Plugs – Type) 
Add the following paragraphs: 
Mains plugs of non-permanently installed 
equipment shall comply with: 
a) 
CSA C22.2 No 21 for moulded-on type 
attachment plugs; and 
b) 
CSA C22.2 No 42 for disassembly type 
attachment plugs (dimensional requirements are 
also specified in IEC 60906-2). 
CSA approved attachment plug 
Class II equipment provided with a general 
purpose mains outlet, or lampholder, shall be 
provided with a polarized-type plug.  
 
N/A 
If the plug is a polarized type, single pole switches 
or over current protectors shall not be  
connected in the identified conductor. 
 
Page 9 of 11 
 
Report No.: 171153  
 
 
ATTACHMENT 6 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
16 
16.1 
External flexible cords 
Replace this clause with the following: 
Flexible cord used for mains supply shall comply 
with the requirements of CSA C22.2 No 49. The 
cord type shall be in accordance with Table 4 of 
CSA C22.2 No 1. 
The attachment plug shall be rated not less than 
125% of the apparatus rated current. 
Cord sets shall comply with the requirements of 
CSA C22.2 No 21. 
Non-detachable flexible cables and cords of Class 
I apparatus shall be provided with a green/yellow 
core connected to the protective earthing terminal 
of the apparatus and, if a plug is provided, to the 
protective earthing contact of the plug. 
Compliance is checked by inspection. 
Note: The colour of cores of flexible mains cords is 
contained in IEC 60173[4]. 
Complying with CSA C22.2. 
See appended table, list of 
critical components.
 
17.9A 
17.9A.1 
Adhesive securement and conductive coatings 
Add the following clause: 
Adhesive securement 
The following parts, the displacement of which may 
result in a fire or shock hazard, shall not be 
secured solely by adhesive, unless the adhesive 
system complies with the resistance to external 
forces test of Clause 9.1.7, the bump test of 
Clause 12.1.1, and the impact test of Clause 
12.1.3, after conditioning in accordance with 
Clause 17.9A.2: 
a)  internal metal parts/conductive coatings; 
b)  barriers; and 
c)  required enclosure parts. 
Note: Cathode ray tubes are excluded from this 
test. 
 
N/A 
17.9A.2 
17.9A.2.1 
Adhesive and conductive coating securement 
conditioning 
General:   
Where required by Clause 17.9A.1, one sample of 
the apparatus or enclosure section shall be 
conditioned in accordance with the requirements of 
Clause 17.9A.2.2.  Equivalent ageing test data 
supplied by the manufacturer will be considered in 
lieu of ageing. 
 
N/A 
Page 10 of 11 
 
Report No.: 171153  
 
 
ATTACHMENT 6 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065J 
17.9A.2.2 
Ageing 
 
Day 1:
  Place in oven at 100 ± 1ºC for 1 week, or 82 
± 1ºC for 8 weeks at the manufacturer’s option. 
Day 8 or Day 57: 
1.  Remove from oven and leave at room temperature 
for 1 h. 
2.  Place in freezer at –35ºC for 2 h. 
3.  Remove from freezer and allow to reach room 
temperature overnight. 
 
Day 9 or Day 58: 
1.  Place in a compartment at 96% relative humidity 
for 3 h. 
2.  Remove and leave at room temperature and 
humidity for 1 h. 
3.  Place in over at a temperature selected in the first 
cycle for 3 h. 
4.  Remove and allow to come to room temperature 
overnight. 
 
Day 10 or Day 59: 
1.  Place in freezer at –35ºC for 2 h. 
2.  Remove and leave at room temperature for 1 h., 
3.  Place in humidity chamber at 96% relative 
humidity for 3 h. 
4.  Remove and allow to come to room temperature 
overnight. 
 
Day 11 or Day 60: 
1.  Place in oven at the temperature selected in the 
first cycle for 3 h. 
2.  Remove for 1 h. 
3.  Place in freezer at –35ºC for 2 h. 
4.  Remove and allow to come to room temperature 
overnight. 
 
Day 12 or Day 61: 
1.  Place in humidity chamber at 96% relative 
humidity for 3 h. 
2.  Remove and perform mechanical tests as required 
by Clause 17.9A.1 as applicable. 
 
N/A 