JBL ON AIR WIRELESS (serv.man2) EMC - CB Certificate ▷ View online
Report No. U1011006-610
Page 17 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
3.2.7
Protection against mechanical damage
N/A
3.2.8
Cord guards
N/A
Diameter or minor dimension D (mm); test mass (g)
................................................................................ :
................................................................................ :
Radius of curvature of cord (mm) ........................... :
3.2.9
Supply wiring space
N/A
3.3
Wiring terminals for connection of external conductors
Class III equipment. No direct connection to mains supply.
N/A
3.3.1
Wiring terminals
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3
Screw terminals
N/A
3.3.4
Conductor sizes to be connected
N/A
Rated current (A), cord/cable type, cross-sectional
area (mm
area (mm
2
) ............................................................. :
3.3.5
Wiring terminal sizes
N/A
Rated current (A), type, nominal thread diameter
(mm) ...................................................................... :
(mm) ...................................................................... :
3.3.6
Wiring terminal design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8
Stranded wire
N/A
3.4
Disconnection from the mains supply
Class III equipment. No direct connection to mains supply.
N/A
3.4.1
General requirement
N/A
3.4.2
Disconnect devices
N/A
3.4.3
Permanently connected equipment
N/A
3.4.4
Parts which remain energized
N/A
3.4.5
Switches in flexible cords
N/A
3.4.6
Number of poles - single-phase and d.c. equipment
N/A
3.4.7
Number of poles - three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10
Interconnected equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
P
3.5.1
General requirements
See below.
P
Report No. U1011006-610
Page 18 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
3.5.2
Types of interconnection circuits ........................... :
Interconnection circuits of
SELV through sec connector.
SELV through sec connector.
P
3.5.3
ELV circuits as interconnection circuits
No ELV interconnection.
N/A
3.5.4
Data ports for additional equipment
The equipment is power
supplied from the power
adaptor which is complied with
the requirement of Limited
Power Source.
supplied from the power
adaptor which is complied with
the requirement of Limited
Power Source.
P
4
PHYSICAL REQUIREMENTS
P
4.1
Stability
N/A
Angle of 10°
The weight of equipment does
not exceed 7kg.
not exceed 7kg.
N/A
Test force (N) ........................................................ : Equipment is not a floor
standing unit.
N/A
4.2
Mechanical strength
The equipment is power supplied from the external power adaptor which is complied
with the requirement of Limited Power Source. No risk of electrical shock or energy
hazards.
with the requirement of Limited Power Source. No risk of electrical shock or energy
hazards.
N/A
4.2.1
General
N/A
4.2.2
Steady force test, 10 N
N/A
4.2.3
Steady force test, 30 N
N/A
4.2.4
Steady force test, 250 N
N/A
4.2.5
Impact test
N/A
Fall test
N/A
Swing test
N/A
4.2.6
Drop test; height (mm) ........................................... :
N/A
4.2.7
Stress relief test
N/A
4.2.8
Cathode ray tubes
N/A
Picture tube separately certified ............................ :
N/A
4.2.9
High pressure lamps
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) ....... :
N/A
4.3
Design and construction
P
4.3.1
Edges and corners
Edges and corners of the
enclosure are rounded.
enclosure are rounded.
P
4.3.2
Handles and manual controls; force (N) ............. :
No handles or controls used.
N/A
4.3.3
Adjustable controls
No hazardous adjustable
controls.
controls.
N/A
Report No. U1011006-610
Page 19 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
4.3.4
Securing of parts
Mechanical fixings in such a
way designed that they will
withstand mechanical stress
occurring in normal use.
way designed that they will
withstand mechanical stress
occurring in normal use.
P
4.3.5
Connection by plugs and sockets
No misconnection of plugs,
connections or sockets
possible.
connections or sockets
possible.
P
4.3.6
Direct plug-in equipment
Not such equipment.
N/A
Torque .................................................................. :
Same as above.
Compliance with the relevant mains plug standard
............................................................................... :
............................................................................... :
Same as above.
N/A
4.3.7
Heating elements in earthed equipment
No heating element.
N/A
4.3.8
Batteries
Equipment does not contain
batteries except for the
remote control, which doesn’t
need further test.
batteries except for the
remote control, which doesn’t
need further test.
N/A
- Overcharging of a rechargeable battery
Same as above.
N/A
- Unintentional charging of a non-rechargeable
battery
battery
Same as above.
N/A
- Reverse charging of a rechargeable battery
Same as above.
N/A
- Excessive discharging rate for any battery
Same as above.
N/A
4.3.9
Oil and grease
EUT in intended use not
considered to be exposed to
oil and grease.
considered to be exposed to
oil and grease.
N/A
4.3.10
Dust, powders, liquids and gases
EUT in intended use does not
produce dust or use powders,
liquids or gases.
produce dust or use powders,
liquids or gases.
N/A
4.3.11
Containers for liquids or gases
No such containers provided.
N/A
4.3.12
Flammable liquids ................................................ :
No flammable liquids used.
N/A
Quantity of liquid (l) ............................................... :
Same as above.
N/A
Flash point (°C) .................................................... :
Same as above.
N/A
4.3.13
Radiation
See below.
P
4.3.13.1
General
No concerned radiation within
this equipment.
this equipment.
P
4.3.13.2
Ionizing radiation
No ionizing radiation or
flammable liquids present.
flammable liquids present.
N/A
Measured radiation (pA/kg) .................................. :
Same as above.
Measured high-voltage (kV) ................................. :
Same as above.
Measured focus voltage (kV) ................................ :
Same as above.
CRT markings ...................................................... :
Same as above.
4.3.13.3
Effect of ultraviolet (UV) radiation on materials
No UV radiation.
N/A
Part, property, retention after test, flammability
classification ......................................................... :
classification ......................................................... :
Same as above.
N/A
Report No. U1011006-610
Page 20 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
4.3.13.4
Human exposure to ultraviolet (UV) radiation ...... :
Same as above.
N/A
4.3.13.5
Laser (including LEDs)
AEL of LED far below the
limiting values for LED Class
1.
limiting values for LED Class
1.
P
Laser class ........................................................... :
Below Class 1.
4.3.13.6
Other types ........................................................... :
No such consideration.
N/A
4.4
Protection against hazardous moving parts
No hazardous moving parts within this equipment.
N/A
4.4.1
General
N/A
4.4.2
Protection in operator access areas ..................... :
N/A
4.4.3
Protection in restricted access locations .............. :
N/A
4.4.4
Protection in service access areas
N/A
4.5
Thermal requirements
P
4.5.1
General
See below.
P
4.5.2
Temperature tests
See appended table 4.5.
P
Normal load condition per Annex L ...................... :
EUT is operated according to
the operating instructions.
the operating instructions.
4.5.3
Temperature limits for materials
See appended table 4.5.
P
4.5.4
Touch temperature limits
See appended table 4.5.
P
4.5.5
Resistance to abnormal heat ................................ :
Class III equipment.
N/A
4.6
Openings in enclosures
P
4.6.1
Top and side openings
No hazardous voltage or
energy hazard within 5º angle
of projection area.
energy hazard within 5º angle
of projection area.
P
Dimensions (mm) ................................................................
See appended table 4.6.1,
4.6.2 in measurement section.
4.6.2 in measurement section.
4.6.2
Bottoms of fire enclosures
See sub-clause 4.7.2.2.
The fire enclosure is not
required.
The fire enclosure is not
required.
N/A
Construction of the bottomm, dimensions (mm) .. :
See appended table 4.6.1,
4.6.2 in measurement section.
4.6.2 in measurement section.
4.6.3
Doors or covers in fire enclosures
No doors or covers provided.
N/A
4.6.4
Openings in transportable equipment
Not transportable equipment.
N/A
4.6.4.1
Constructional design measures
Same as above.
N/A
Dimensions (mm) ................................................. :
Same as above.
4.6.4.2
Evaluation measures for larger openings
Same as above.
N/A
4.6.4.3
Use of metallized parts
Same as above.
N/A
Click on the first or last page to see other ON AIR WIRELESS (serv.man2) service manuals if exist.