JBL ON AIR WIRELESS (serv.man2) EMC - CB Certificate ▷ View online
Report No. U1011006-610
Page 5 of 42
TRF No. IECEN60950_1C
General product information:
This equipment, model JBL ON AIR
™ WIRELESS, is a Wireless Speaker which is intended to use within
information technology equipment.
Other comments:
The maximum operational ambient temperature as specified by the manufacturer is 40°C.
The equipment is power supplied from the power adaptor which is complied with the requirement of Limited
Power Source. Otherwise, the adaptor which is intended to be used with this equipment in the regional
market should be stated in the specified manufacturers and models in the instruction by suitable regional
languages.
Power Source. Otherwise, the adaptor which is intended to be used with this equipment in the regional
market should be stated in the specified manufacturers and models in the instruction by suitable regional
languages.
The warning caution ”Use only power supplies listed in the manual” or ”For applicable power supplies see
user instructions” must be seated in the marking plate by suitable regional language during the end-use
market.
user instructions” must be seated in the marking plate by suitable regional language during the end-use
market.
The label drawing is a draft of an artwork for marking plates pending approval by National Certification Bodies
and it shall be affixed to products prior to such an approval.
and it shall be affixed to products prior to such an approval.
Factory(ies):
DONGGUAN G-COM COMPUTER CO., LTD.
YIN HWU INDUSTRIAL AREA, 1ST ROW YIN SHAN RD, QINGXI TOWN, DONGGUAN GUANGDONG,
CHINA
DONGGUAN G-COM COMPUTER CO., LTD.
YIN HWU INDUSTRIAL AREA, 1ST ROW YIN SHAN RD, QINGXI TOWN, DONGGUAN GUANGDONG,
CHINA
Attachments to this Test Report:
•
Measurement Section
•
National Differences
•
Photo Documentation
Report No. U1011006-610
Page 6 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
1
GENERAL
P
1.5
Components
P
1.5.1
General
See below.
P
Comply with IEC 60950 or relevant component
standard
standard
Components which were
found to affect safety aspects
comply with the requirements
of this standard or with the
safety aspects of the relevant
IEC/EN component standards.
See appended table 1.5.1.
found to affect safety aspects
comply with the requirements
of this standard or with the
safety aspects of the relevant
IEC/EN component standards.
See appended table 1.5.1.
P
1.5.2
Evaluation and testing of components
Components that are certified
to IEC and /or national
standards are used correctly
within their ratings.
Components not covered by
IEC standards are tested
under the conditions present
in the equipment.
to IEC and /or national
standards are used correctly
within their ratings.
Components not covered by
IEC standards are tested
under the conditions present
in the equipment.
P
1.5.3
Thermal controls
No thermal controls provided.
N/A
1.5.4
Transformers
No safety isolation
transformer in this equipment.
transformer in this equipment.
N/A
1.5.5
Interconnecting cables
Interconnecting cables comply
with the relevant requirements
of this standard.
with the relevant requirements
of this standard.
P
1.5.6
Capacitors bridging insulation
Class III equipment.
N/A
1.5.7
Resistors bridging insulation
Class III equipment.
N/A
1.5.7.1
Resistors bridging functional, basic or
supplementary insulation
supplementary insulation
Same as above.
N/A
1.5.7.2
Resistors bridging double or reinforced insulation
between a.c. mains and other circuits
between a.c. mains and other circuits
Same as above.
N/A
1.5.7.3
Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable
between a.c. mains and antenna or coaxial cable
Same as above.
N/A
1.5.8
Components in equipment for IT power systems
Class III equipment.
N/A
1.5.9
Surge suppressors
No such suppressor provided.
N/A
1.5.9.1
General
Same as above.
N/A
1.5.9.2
Protection of VDRs
Same as above.
N/A
1.5.9.3
Bridging of functional insulation by a VDR
Same as above.
N/A
1.5.9.4
Bridging of basic insulation by a VDR
Same as above.
N/A
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
insulation by a VDR
Same as above.
N/A
1.6
Power interface
P
Report No. U1011006-610
Page 7 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
1.6.1
AC power distribution systems
Equipment is not directly
connected to the AC mains
supply.
connected to the AC mains
supply.
N/A
1.6.2
Input current
Highest load according to
1.2.2.1 for this equipment is
received external signal
specified in appended table
1.6.2 and operated
continuously and USB port
loaded 2.5W.
(see appended table 1.6.2)
1.2.2.1 for this equipment is
received external signal
specified in appended table
1.6.2 and operated
continuously and USB port
loaded 2.5W.
(see appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
This appliance is not hand-
held equipment.
held equipment.
N/A
1.6.4
Neutral conductor
Equipment is not directly
connected to the AC mains
supply.
connected to the AC mains
supply.
N/A
1.7
Marking and instructions
P
1.7.1
Power rating
All information is provided on
a label.
a label.
P
Rated voltage(s) or voltage range(s) (V) ............... : DC 12V
P
Symbol for nature of supply, for d.c. only ............... : DC Symbol used.
P
Rated frequency or rated frequency range (Hz) .... : Equipment is not directly
connected to the AC mains
supply.
supply.
N/A
Rated current (mA or A) ........................................ : 2A
P
Manufacturer’s name or trade-mark or identification
mark ...................................................................... :
mark ...................................................................... :
P
Model identification or type reference .................... : JBL ON AIR
™ WIRELESS
P
Symbol for Class II equipment only ....................... : Class III equipment.
N/A
Other markings and symbols ................................. : Additional symbols or
markings do not give rise to
misunderstanding.
misunderstanding.
P
1.7.2
Safety instructions and marking
See below.
P
1.7.2.1
General
The user’s manual contains
information for operation,
installation, servicing,
transport, storage and
technical data. The operation
guide is provided to the user.
information for operation,
installation, servicing,
transport, storage and
technical data. The operation
guide is provided to the user.
P
1.7.2.2
Disconnect devices
This equipment is not
permanently connected
equipment or pluggable
equipment.
permanently connected
equipment or pluggable
equipment.
N/A
Report No. U1011006-610
Page 8 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
1.7.2.3
Overcurrent protective device
This equipment is not
permanently connected
equipment or pluggable
equipment.
permanently connected
equipment or pluggable
equipment.
N/A
1.7.2.4
IT power distribution systems
Class III equipment.
N/A
1.7.2.5
Operator access with a tool
No tool is required to gain
access to operator access
area.
access to operator access
area.
N/A
1.7.2.6
Ozone
No ozone produces within this
equipment.
equipment.
N/A
1.7.3
Short duty cycles
Equipment is designed for
continuous operation.
continuous operation.
N/A
1.7.4
Supply voltage adjustment ................................... :
No voltage adjustment device
provided.
provided.
N/A
Methods and means of adjustment; reference to
installation instructions ......................................... :
installation instructions ......................................... :
Same as above.
N/A
1.7.5
Power outlets on the equipment ........................... :
No outlet provided.
N/A
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) .......................... :
characteristics, cross-reference) .......................... :
No such component within the
equipment.
equipment.
N/A
1.7.7
Wiring terminals
Class III equipment.
N/A
1.7.7.1
Protective earthing and bonding terminals ........... :
N/A
1.7.7.2
Terminals for a.c. mains supply conductors
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
N/A
1.7.8
Controls and indicators
See below.
P
1.7.8.1
Identification, location and marking ...................... :
The marking and indication is
located that indication of
function clearly.
located that indication of
function clearly.
P
1.7.8.2
Colours ................................................................ :
No safety relevant controls or
indicators.
indicators.
N/A
1.7.8.3
Symbols according to IEC 60417 ......................... :
No such symbol provided.
N/A
1.7.8.4
Markings using figures ....................................... :
No indicators for different
positions.
positions.
N/A
1.7.9
Isolation of multiple power sources ..................... :
Class III equipment.
N/A
1.7.10
Thermostats and other regulating devices .......... :
No such device provided.
N/A
1.7.11
Durability
The labels were subjected to
the permanence of marking
test. The labels were rubbed
with cloth soaked with water for
15 s and then again for 15 s
with the cloth soaked with
petroleum spirit.
After this test there was no
damage to the labels. The
marking on the labels did not
fade. There was no curling or
lifting of the label's edges.
the permanence of marking
test. The labels were rubbed
with cloth soaked with water for
15 s and then again for 15 s
with the cloth soaked with
petroleum spirit.
After this test there was no
damage to the labels. The
marking on the labels did not
fade. There was no curling or
lifting of the label's edges.
P