Document
EMC - CB Certificate
Brand
Device
Audio
File
on-air-wireless-sm2.pdf
Date

JBL ON AIR WIRELESS (serv.man2) EMC - CB Certificate ▷ View online

Report No. U1011006-610 
Page 5 of 42 
 
TRF No. IECEN60950_1C 
 
General product information: 
This equipment, model JBL ON AIR
™ WIRELESS, is a Wireless Speaker which is intended to use within 
information technology equipment. 
 
Other comments: 
The maximum operational ambient temperature as specified by the manufacturer is 40°C. 
The equipment is power supplied from the power adaptor which is complied with the requirement of Limited 
Power Source. Otherwise, the adaptor which is intended to be used with this equipment in the regional 
market should be stated in the specified manufacturers and models in the instruction by suitable regional 
languages. 
The warning caution ”Use only power supplies listed in the manual” or ”For applicable power supplies see 
user instructions” must be seated in the marking plate by suitable regional language during the end-use 
market. 
The label drawing is a draft of an artwork for marking plates pending approval by National Certification Bodies 
and it shall be affixed to products prior to such an approval. 
 
Factory(ies): 
DONGGUAN G-COM COMPUTER CO., LTD. 
YIN HWU INDUSTRIAL AREA, 1ST ROW YIN SHAN RD, QINGXI TOWN, DONGGUAN GUANGDONG, 
CHINA 
 
Attachments to this Test Report: 
  Measurement Section 
  National Differences 
  Photo Documentation 
Report No. U1011006-610
 
Page 6 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
GENERAL 
 
1.5 
Components 
1.5.1 
General 
See below. 
 
Comply with IEC 60950 or relevant component 
standard  
Components which were 
found to affect safety aspects 
comply with the requirements 
of this standard or with the 
safety aspects of the relevant 
IEC/EN component standards. 
See appended table 1.5.1. 
1.5.2 
Evaluation and testing of components 
Components that are certified 
to IEC and /or national 
standards are used correctly 
within their ratings. 
Components not covered by 
IEC standards are tested 
under the conditions present 
in the equipment. 
1.5.3 
Thermal controls 
No thermal controls provided. 
N/A 
1.5.4 
Transformers 
No safety isolation 
transformer in this equipment. 
N/A 
1.5.5 
Interconnecting cables 
Interconnecting cables comply 
with the relevant requirements 
of this standard. 
1.5.6 
Capacitors bridging insulation  
Class III equipment. 
N/A 
1.5.7 
Resistors bridging insulation 
Class III equipment. 
N/A 
1.5.7.1 
Resistors bridging functional, basic or 
supplementary insulation 
Same as above. 
N/A 
1.5.7.2 
Resistors bridging double or reinforced insulation 
between a.c. mains and other circuits 
Same as above.  
N/A 
1.5.7.3 
Resistors bridging double or reinforced insulation 
between a.c. mains and antenna or coaxial cable  
Same as above. 
N/A 
1.5.8 
Components in equipment for IT power systems 
Class III equipment. 
N/A 
1.5.9 
Surge suppressors 
No such suppressor provided. 
N/A 
1.5.9.1 
General 
Same as above. 
N/A 
1.5.9.2 
Protection of VDRs 
Same as above. 
N/A 
1.5.9.3 
Bridging of functional insulation by a VDR 
Same as above. 
N/A 
1.5.9.4 
Bridging of basic insulation by a VDR 
Same as above. 
N/A 
1.5.9.5 
Bridging of supplementary, double or reinforced 
insulation by a VDR 
Same as above. 
N/A 
 
1.6 
Power interface 
Report No. U1011006-610
 
Page 7 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
1.6.1 
AC power distribution systems 
Equipment is not directly 
connected to the AC mains 
supply. 
N/A 
1.6.2 
Input current 
Highest load according to 
1.2.2.1 for this equipment is 
received external signal 
specified in appended table 
1.6.2 and operated 
continuously and USB port 
loaded 2.5W. 
(see appended table 1.6.2) 
1.6.3 
Voltage limit of hand-held equipment 
This appliance is not hand-
held equipment. 
N/A 
1.6.4 
Neutral conductor  
Equipment is not directly 
connected to the AC mains 
supply. 
N/A 
 
1.7 
Marking and instructions 
1.7.1 
Power rating  
All information is provided on 
a label. 
 
Rated voltage(s) or voltage range(s) (V)  ............... :  DC 12V 
 
Symbol for nature of supply, for d.c. only ............... :  DC Symbol used. 
 
Rated frequency or rated frequency range (Hz)  .... :  Equipment is not directly 
connected to the AC mains 
supply. 
N/A 
 
Rated current (mA or A)  ........................................ :  2A 
 
Manufacturer’s name or trade-mark or identification 
mark  ...................................................................... : 
 
 
Model identification or type reference  .................... :  JBL ON AIR
™ WIRELESS 
 
Symbol for Class II equipment only  ....................... :  Class III equipment. 
N/A 
 
Other markings and symbols ................................. :  Additional symbols or 
markings do not give rise to 
misunderstanding. 
1.7.2 
Safety instructions and marking 
See below. 
1.7.2.1 
General 
The user’s manual contains 
information for operation, 
installation, servicing, 
transport, storage and 
technical data. The operation 
guide is provided to the user. 
1.7.2.2 
Disconnect devices 
This equipment is not 
permanently connected 
equipment or pluggable 
equipment. 
N/A 
Report No. U1011006-610
 
Page 8 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
1.7.2.3 
Overcurrent protective device 
This equipment is not 
permanently connected 
equipment or pluggable 
equipment. 
N/A 
1.7.2.4 
IT power distribution systems 
Class III equipment. 
N/A 
1.7.2.5 
Operator access with a tool 
No tool is required to gain 
access to operator access 
area. 
N/A 
1.7.2.6 
Ozone 
No ozone produces within this 
equipment. 
N/A 
1.7.3 
Short duty cycles 
Equipment is designed for 
continuous operation. 
N/A 
1.7.4 
Supply voltage adjustment  ................................... : 
No voltage adjustment device 
provided. 
N/A 
 
Methods and means of adjustment; reference to 
installation instructions  ......................................... : 
Same as above. 
N/A 
1.7.5 
Power outlets on the equipment  ........................... : 
No outlet provided. 
N/A 
1.7.6 
Fuse identification (marking, special fusing 
characteristics, cross-reference)  .......................... : 
No such component within the 
equipment. 
N/A 
1.7.7 
Wiring terminals 
Class III equipment. 
N/A 
1.7.7.1 
Protective earthing and bonding terminals  ........... : 
 
N/A 
1.7.7.2 
Terminals for a.c. mains supply conductors  
 
N/A 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
N/A 
1.7.8 
Controls and indicators 
See below. 
1.7.8.1 
Identification, location and marking  ...................... : 
The marking and indication is 
located that indication of 
function clearly. 
1.7.8.2 
Colours   ................................................................ : 
No safety relevant controls or 
indicators. 
N/A 
1.7.8.3 
Symbols according to IEC 60417 ......................... : 
No such symbol provided. 
N/A 
1.7.8.4 
Markings using figures   ....................................... : 
No indicators for different 
positions. 
N/A 
1.7.9 
Isolation of multiple power sources  ..................... : 
Class III equipment. 
N/A 
1.7.10 
Thermostats and other regulating devices  .......... : 
No such device provided. 
N/A 
1.7.11 
Durability 
The labels were subjected to 
the permanence of marking 
test. The labels were rubbed 
with cloth soaked with water for 
15 s and then again for 15 s 
with the cloth soaked with 
petroleum spirit. 
After this test there was no 
damage to the labels. The 
marking on the labels did not 
fade. There was no curling or 
lifting of the label's edges. 