JBL ON AIR WIRELESS (serv.man2) EMC - CB Certificate ▷ View online

Report No. U1011006-610
 
Page 9 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
1.7.12 
Removable parts 
No removable part provided 
except for the remote control. 
N/A 
1.7.13 
Replaceable batteries  .......................................... : 
No replaceable batteries 
provided. 
N/A 
 
Language(s)  ........................................................ : 
Same as above. 
 
1.7.14 
Equipment for restricted access locations ............ : 
No restricted access location. 
N/A 
 
PROTECTION FROM HAZARDS 
The equipment is power supplied from the external power adaptor which is complied 
with the requirement of Limited Power Source. No risk of electrical shock or energy 
hazards. 
2.1 
Protection from electric shock and energy hazards 
2.1.1 
Protection in operator access areas  
See below. 
2.1.1.1 
Access to energized parts 
No access with test finger and 
test pin to any parts with only 
basic insulation to ELV or 
hazardous voltage. Any 
hazardous parts accessible are 
unlikely. 
 
Test by inspection  .................................................. :  Same as above. 
 
Test with test finger (Figure 2A)  ............................ :  Same as above. 
 
Test with test pin (Figure 2B)  ................................ :  Same as above. 
 
Test with test probe (Figure 2C)  ............................ :  No TNV circuits in this 
equipment. 
N/A 
2.1.1.2 
Battery compartments  
No battery compartments and 
TNV circuits. 
N/A 
2.1.1.3 
Access to ELV wiring 
No ELV wiring in operator 
accessible area. 
N/A 
 
Working voltage (Vpeak or Vrms); minimum 
distance through insulation (mm) 
Same as above. 
 
2.1.1.4 
Access to hazardous voltage circuit wiring 
No hazardous voltage wiring in 
operator accessible area. 
N/A 
2.1.1.5 
Energy hazards  ..................................................... :  No energy hazard in operator 
access area. 
2.1.1.6 
Manual controls 
No conductive shaft of 
operating knob and handle. 
N/A 
2.1.1.7 
Discharge of capacitors in equipment 
Class III equipment. 
N/A 
 
Measured voltage (V); time-constant (s) ................ :  Same as above. 
 
2.1.1.8 
Energy hazards – d.c. mains supply 
Class III equipment.. 
N/A 
 
a) Capacitor connected to the d.c. mains supply  .. :  Same as above. 
N/A 
 
Same as above. 
N/A 
2.1.1.9 
Audio amplifiers  ..................................................... :  See sub-clause 2.1.1.1 
Report No. U1011006-610
 
Page 10 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
2.1.2 
Protection in service access areas 
No maintenance work in 
operation mode necessary. 
N/A 
2.1.3 
Protection in restricted access locations 
The unit is not intended to be 
used in restricted locations. 
N/A 
 
2.2 
SELV circuits 
2.2.1 
General requirements 
See below. 
2.2.2 
Voltages under normal conditions (V)  ................... :  Between any SELV circuits 
42.4Vpeak or 60Vdc are not 
exceeded. 
2.2.3 
Voltages under fault conditions (V)  ....................... :  Single fault did not cause 
excessive voltage in 
accessible SELV circuits. 
Limits of 71Vpeak and 120V 
dc were not exceed and SELV 
limits not for longer than 0.2 
seconds. 
2.2.4 
Connection of SELV circuits to other circuits  ...... : 
See 2.2.2 and 2.2.3. 
No direct connection between 
SELV and any primary 
circuits. 
N/A 
 
2.3 
TNV circuits 
No such circuit within this equipment. 
N/A 
2.3.1 
Limits 
 
N/A 
 
Type of TNV circuits ............................................... :   
 
2.3.2 
Separation from other circuits and from accessible 
parts 
 
N/A 
2.3.2.1 
General requirements 
 
N/A 
2.3.2.2 
Protection by basic insulation 
 
N/A 
2.3.2.3 
Protection by earthing 
 
N/A 
2.3.2.4 
Protection by other constructions  .......................... :   
N/A 
2.3.3 
Separation from hazardous voltages 
 
N/A 
 
Insulation employed ................................................ :   
 
2.3.4 
Connection of TNV circuits to other circuits 
 
N/A 
 
Insulation employed ................................................ :   
 
2.3.5 
Test for operating voltages generated externally 
 
N/A 
 
2.4 
Limited current circuits 
No such circuit within this equipment. 
N/A 
2.4.1 
General requirements 
 
N/A 
2.4.2 
Limit values 
 
N/A 
Report No. U1011006-610
 
Page 11 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
 
Frequency (Hz) ....................................................... :   
 
 
Measured current (mA) .......................................... :   
 
 
Measured voltage (V) ............................................. :   
 
 
Measured circuit capacitance (nF or µF) ................ :   
 
2.4.3 
Connection of limited current circuits to other 
circuits 
 
N/A 
 
2.5 
Limited power sources 
The equipment is power supplied from the external power adaptor which is complied 
with the requirement of Limited Power Source. No risk of electrical shock or energy 
hazards. 
N/A 
 
a) Inherently limited output 
 
N/A 
 
b) Impedance limited output 
 
N/A 
 
c) Regulating network limited output under normal 
operating and single fault condition 
 
N/A 
 
d) Overcurrent protective device limited output 
 
N/A 
 
Max. output voltage (V), max. output current (A), 
max. apparent power (VA) ..................................... : 
 
 
 
Current rating of overcurrent protective device (A) 
 
 
 
2.6 
Provisions for earthing and bonding 
Class III equipment. 
N/A 
2.6.1 
Protective earthing 
 
N/A 
2.6.2 
Functional earthing 
 
N/A 
2.6.3 
Protective earthing and protective bonding 
conductors 
 
N/A 
2.6.3.1 
General 
 
N/A 
2.6.3.2 
Size of protective earthing conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm2), 
AWG ....................................................................... : 
 
 
2.6.3.3 
Size of protective bonding conductors 
 
N/A 
 
Rated current (A), cross-sectional area (mm2), 
AWG ....................................................................... : 
 
 
 
Protective current rating (A), cross-sectional area 
(mm
2
), AWG ........................................................... : 
 
 
2.6.3.4 
Resistance of earthing conductors and their 
terminations; resistance (Ω), voltage drop (V), test 
current (A), duration (min) ...................................... : 
 
N/A 
2.6.3.5 
Colour of insulation ................................................. :   
N/A 
2.6.4 
Terminals 
 
N/A 
2.6.4.1 
General 
 
N/A 
Report No. U1011006-610
 
Page 12 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
2.6.4.2 
Protective earthing and bonding terminals 
 
N/A 
 
Rated current (A), type, nominal thread diameter 
(mm) ....................................................................... : 
 
 
2.6.4.3 
Separation of the protective earthing conductor 
from protective bonding conductors 
 
N/A 
2.6.5 
Integrity of protective earthing 
 
N/A 
2.6.5.1 
Interconnection of equipment 
 
N/A 
2.6.5.2 
Components in protective earthing conductors and 
protective bonding conductors 
 
N/A 
2.6.5.3 
Disconnection of protective earth 
 
N/A 
2.6.5.4 
Parts that can be removed by an operator 
 
N/A 
2.6.5.5 
Parts removed during servicing 
 
N/A 
2.6.5.6 
Corrosion resistance 
 
N/A 
2.6.5.7 
Screws for protective bonding 
 
N/A 
2.6.5.8 
Reliance on telecommunication network or cable 
distribution system 
 
N/A 
 
2.7 
Overcurrent and earth fault protection in primary circuits 
Class III equipment. 
N/A 
2.7.1 
Basic requirements 
 
N/A 
 
Instructions when protection relies on building 
installation 
 
N/A 
2.7.2 
Faults not simulated in 5.3.7 
 
N/A 
2.7.3 
Short-circuit backup protection 
 
N/A 
2.7.4 
Number and location of protective devices  ........... : 
 
N/A 
2.7.5 
Protection by several devices 
 
N/A 
2.7.6 
Warning to service personnel ................................. : 
 
N/A 
 
2.8 
Safety interlocks 
No such device within this equipment. 
N/A 
2.8.1 
General principles 
 
N/A 
2.8.2 
Protection requirements 
 
N/A 
2.8.3 
Inadvertent reactivation 
 
N/A 
2.8.4 
Fail-safe operation 
 
N/A 
2.8.5 
Moving parts 
 
N/A 
2.8.6 
Overriding  
 
N/A 
2.8.7 
Switches and relays  
 
N/A 
2.8.7.1 
Contact gaps (mm)  ................................................ :   
N/A 
2.8.7.2 
Overload test 
 
N/A 
Page of 62