JBL ON AIR WIRELESS (serv.man2) EMC - CB Certificate ▷ View online
Report No. U1011006-610
Page 9 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
1.7.12
Removable parts
No removable part provided
except for the remote control.
except for the remote control.
N/A
1.7.13
Replaceable batteries .......................................... :
No replaceable batteries
provided.
provided.
N/A
Language(s) ........................................................ :
Same as above.
1.7.14
Equipment for restricted access locations ............ :
No restricted access location.
N/A
2
PROTECTION FROM HAZARDS
The equipment is power supplied from the external power adaptor which is complied
with the requirement of Limited Power Source. No risk of electrical shock or energy
hazards.
with the requirement of Limited Power Source. No risk of electrical shock or energy
hazards.
P
2.1
Protection from electric shock and energy hazards
P
2.1.1
Protection in operator access areas
See below.
P
2.1.1.1
Access to energized parts
No access with test finger and
test pin to any parts with only
basic insulation to ELV or
hazardous voltage. Any
hazardous parts accessible are
unlikely.
test pin to any parts with only
basic insulation to ELV or
hazardous voltage. Any
hazardous parts accessible are
unlikely.
P
Test by inspection .................................................. : Same as above.
P
Test with test finger (Figure 2A) ............................ : Same as above.
P
Test with test pin (Figure 2B) ................................ : Same as above.
P
Test with test probe (Figure 2C) ............................ : No TNV circuits in this
equipment.
N/A
2.1.1.2
Battery compartments
No battery compartments and
TNV circuits.
TNV circuits.
N/A
2.1.1.3
Access to ELV wiring
No ELV wiring in operator
accessible area.
accessible area.
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
distance through insulation (mm)
Same as above.
2.1.1.4
Access to hazardous voltage circuit wiring
No hazardous voltage wiring in
operator accessible area.
operator accessible area.
N/A
2.1.1.5
Energy hazards ..................................................... : No energy hazard in operator
access area.
P
2.1.1.6
Manual controls
No conductive shaft of
operating knob and handle.
operating knob and handle.
N/A
2.1.1.7
Discharge of capacitors in equipment
Class III equipment.
N/A
Measured voltage (V); time-constant (s) ................ : Same as above.
2.1.1.8
Energy hazards – d.c. mains supply
Class III equipment..
N/A
a) Capacitor connected to the d.c. mains supply .. : Same as above.
N/A
Same as above.
N/A
2.1.1.9
Audio amplifiers ..................................................... : See sub-clause 2.1.1.1
P
Report No. U1011006-610
Page 10 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
2.1.2
Protection in service access areas
No maintenance work in
operation mode necessary.
operation mode necessary.
N/A
2.1.3
Protection in restricted access locations
The unit is not intended to be
used in restricted locations.
used in restricted locations.
N/A
2.2
SELV circuits
P
2.2.1
General requirements
See below.
P
2.2.2
Voltages under normal conditions (V) ................... : Between any SELV circuits
42.4Vpeak or 60Vdc are not
exceeded.
exceeded.
P
2.2.3
Voltages under fault conditions (V) ....................... : Single fault did not cause
excessive voltage in
accessible SELV circuits.
Limits of 71Vpeak and 120V
dc were not exceed and SELV
limits not for longer than 0.2
seconds.
accessible SELV circuits.
Limits of 71Vpeak and 120V
dc were not exceed and SELV
limits not for longer than 0.2
seconds.
P
2.2.4
Connection of SELV circuits to other circuits ...... :
See 2.2.2 and 2.2.3.
No direct connection between
SELV and any primary
circuits.
No direct connection between
SELV and any primary
circuits.
N/A
2.3
TNV circuits
No such circuit within this equipment.
N/A
2.3.1
Limits
N/A
Type of TNV circuits ............................................... :
2.3.2
Separation from other circuits and from accessible
parts
parts
N/A
2.3.2.1
General requirements
N/A
2.3.2.2
Protection by basic insulation
N/A
2.3.2.3
Protection by earthing
N/A
2.3.2.4
Protection by other constructions .......................... :
N/A
2.3.3
Separation from hazardous voltages
N/A
Insulation employed ................................................ :
2.3.4
Connection of TNV circuits to other circuits
N/A
Insulation employed ................................................ :
2.3.5
Test for operating voltages generated externally
N/A
2.4
Limited current circuits
No such circuit within this equipment.
N/A
2.4.1
General requirements
N/A
2.4.2
Limit values
N/A
Report No. U1011006-610
Page 11 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
Frequency (Hz) ....................................................... :
Measured current (mA) .......................................... :
Measured voltage (V) ............................................. :
Measured circuit capacitance (nF or µF) ................ :
2.4.3
Connection of limited current circuits to other
circuits
circuits
N/A
2.5
Limited power sources
The equipment is power supplied from the external power adaptor which is complied
with the requirement of Limited Power Source. No risk of electrical shock or energy
hazards.
with the requirement of Limited Power Source. No risk of electrical shock or energy
hazards.
N/A
a) Inherently limited output
N/A
b) Impedance limited output
N/A
c) Regulating network limited output under normal
operating and single fault condition
operating and single fault condition
N/A
d) Overcurrent protective device limited output
N/A
Max. output voltage (V), max. output current (A),
max. apparent power (VA) ..................................... :
max. apparent power (VA) ..................................... :
Current rating of overcurrent protective device (A)
2.6
Provisions for earthing and bonding
Class III equipment.
N/A
2.6.1
Protective earthing
N/A
2.6.2
Functional earthing
N/A
2.6.3
Protective earthing and protective bonding
conductors
conductors
N/A
2.6.3.1
General
N/A
2.6.3.2
Size of protective earthing conductors
N/A
Rated current (A), cross-sectional area (mm2),
AWG ....................................................................... :
AWG ....................................................................... :
2.6.3.3
Size of protective bonding conductors
N/A
Rated current (A), cross-sectional area (mm2),
AWG ....................................................................... :
AWG ....................................................................... :
Protective current rating (A), cross-sectional area
(mm
(mm
2
), AWG ........................................................... :
2.6.3.4
Resistance of earthing conductors and their
terminations; resistance (Ω), voltage drop (V), test
current (A), duration (min) ...................................... :
terminations; resistance (Ω), voltage drop (V), test
current (A), duration (min) ...................................... :
N/A
2.6.3.5
Colour of insulation ................................................. :
N/A
2.6.4
Terminals
N/A
2.6.4.1
General
N/A
Report No. U1011006-610
Page 12 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
2.6.4.2
Protective earthing and bonding terminals
N/A
Rated current (A), type, nominal thread diameter
(mm) ....................................................................... :
(mm) ....................................................................... :
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
from protective bonding conductors
N/A
2.6.5
Integrity of protective earthing
N/A
2.6.5.1
Interconnection of equipment
N/A
2.6.5.2
Components in protective earthing conductors and
protective bonding conductors
protective bonding conductors
N/A
2.6.5.3
Disconnection of protective earth
N/A
2.6.5.4
Parts that can be removed by an operator
N/A
2.6.5.5
Parts removed during servicing
N/A
2.6.5.6
Corrosion resistance
N/A
2.6.5.7
Screws for protective bonding
N/A
2.6.5.8
Reliance on telecommunication network or cable
distribution system
distribution system
N/A
2.7
Overcurrent and earth fault protection in primary circuits
Class III equipment.
N/A
2.7.1
Basic requirements
N/A
Instructions when protection relies on building
installation
installation
N/A
2.7.2
Faults not simulated in 5.3.7
N/A
2.7.3
Short-circuit backup protection
N/A
2.7.4
Number and location of protective devices ........... :
N/A
2.7.5
Protection by several devices
N/A
2.7.6
Warning to service personnel ................................. :
N/A
2.8
Safety interlocks
No such device within this equipment.
N/A
2.8.1
General principles
N/A
2.8.2
Protection requirements
N/A
2.8.3
Inadvertent reactivation
N/A
2.8.4
Fail-safe operation
N/A
2.8.5
Moving parts
N/A
2.8.6
Overriding
N/A
2.8.7
Switches and relays
N/A
2.8.7.1
Contact gaps (mm) ................................................ :
N/A
2.8.7.2
Overload test
N/A
Click on the first or last page to see other ON AIR WIRELESS (serv.man2) service manuals if exist.