JBL ON AIR WIRELESS (serv.man2) EMC - CB Certificate ▷ View online
Report No. U1011006-610
Page 21 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
4.6.5
Adhesives for constructional purposes
No such consideration.
N/A
Conditioning temperature (°C), time (weeks) ........ :
Same as above.
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
Use of materials with the
required flammability classes.
required flammability classes.
P
Method 1, selection and application of components
wiring and materials
wiring and materials
Method 1 used.
P
Method 2, application of all of simulated fault
condition tests
condition tests
Same as above.
N/A
4.7.2
Conditions for a fire enclosure
See below.
P
4.7.2.1
Parts requiring a fire enclosure
See below.
N/A
4.7.2.2
Parts not requiring a fire enclosure
The appliance with: Supply of
components in the secondary
circuit by a limited power
source power adaptor. The
components are mounted on
PCB material of flammability
rating V-1 min. The fire
enclosure construction is not
required.
components in the secondary
circuit by a limited power
source power adaptor. The
components are mounted on
PCB material of flammability
rating V-1 min. The fire
enclosure construction is not
required.
P
4.7.3
Materials
See below.
P
4.7.3.1
General
PCB rated accordingly. For
details see table 1.5.1.
details see table 1.5.1.
P
4.7.3.2
Materials for fire enclosures
See sub-clause 4.7.2.2.
The fire enclosure is not
required.
The fire enclosure is not
required.
N/A
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
Same as above.
N/A
4.7.3.4
Materials for components and other parts inside fire
enclosures
enclosures
Same as above.
N/A
4.7.3.5
Materials for air filter assemblies
No air filter assemblies.
N/A
4.7.3.6
Materials used in high-voltage components
No high voltage component.
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
Class III equipment without TNV circuit.
P
5.1
Touch current and protective conductor current
N/A
5.1.1
General
N/A
5.1.2
Configuration of equipment under test (EUT)
N/A
5.1.2.1
Single connection to an a.c. mains supply
N/A
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
supply
N/A
5.1.2.3
Simultaneous multiple connections to an a.c. mains
supply
supply
N/A
Report No. U1011006-610
Page 22 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
5.1.3
Test circuit
N/A
5.1.4
Application of measuring instrument
N/A
5.1.5
Test procedure
N/A
5.1.6
Test measurements
N/A
Supply voltage (V) ................................................ :
Measured touch current (mA) ............................... :
Max. allowed touch current (mA) .......................... :
Measured protective conductor current (mA) ....... :
Max. allowed protective conductor current (mA) ... :
5.1.7
Equipment with touch current exceeding 3,5 mA
N/A
5.1.7.1
General ................................................................. :
N/A
5.1.7.2
Simultaneous multiple connections to the supply
N/A
5.1.8
Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks
cable distribution systems and from
telecommunication networks
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable
distribution system
telecommunication network or to a cable
distribution system
N/A
Supply voltage (V) ................................................ :
Measured touch current (mA) ............................... :
Max. allowed touch current (mA) .......................... :
5.1.8.2
Summation of touch currents from
telecommunication networks
telecommunication networks
N/A
a) EUT with earthed telecommunication ports ..... :
N/A
b) EUT whose telecommunication ports have no
reference to protective earth
reference to protective earth
N/A
5.2
Electric strength
Class III equipment without TNV circuit
N/A
5.2.1
General
N/A
5.2.2
Test procedure
N/A
5.3
Abnormal operating and fault conditions
P
5.3.1
Protection against overload and abnormal operation Ventilation openings blocked
test performed, result see
appended table 5.3.
appended table 5.3.
P
5.3.2
Motors
No motors provided
N/A
5.3.3
Transformers
No safety isolation
transformer in this equipment.
transformer in this equipment.
N/A
5.3.4
Functional insulation .............................................. :
Method c).
See appended table 5.3.
See appended table 5.3.
P
Report No. U1011006-610
Page 23 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
5.3.5
Electromechanical components
No electromechanical
components.
components.
N/A
5.3.6
Audio amplifiers in ITE ......................................... :
The test in accordance with
4.3.4 and 4.3.5 of IEC 60065
has been performed.
See appended table 5.3
4.3.4 and 4.3.5 of IEC 60065
has been performed.
See appended table 5.3
N/A
5.3.7
Simulation of faults
See sub-clause 5.3.4
N/A
5.3.8
Unattended equipment
None of the listed components
provided.
provided.
N/A
5.3.9
Compliance criteria for abnormal operating and
fault conditions
fault conditions
See below.
P
5.3.9.1
During the tests
No fire occur, no emit molten
metal, no hazardous.
metal, no hazardous.
P
5.3.9.2
After the tests
Class III equipment only SELV
inside.
inside.
N/A
6
CONNECTION TO TELECOMMUNICATION NETWORKS
No telecommunication networks circuits within equipment.
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
N/A
Supply voltage (V) ................................................ :
Current in the test circuit (mA) ............................ :
6.1.2.2
Exclusions ............................................................ :
N/A
6.2
Protection of equipment users from overvoltages on telecommunication networks
N/A
6.2.1
Separation requirements
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1
Impulse test
N/A
6.2.2.2
Steady-state test
N/A
6.2.2.3
Compliance criteria
N/A
6.3
Protection of the telecommunication wiring system from overheating
Not such equipment intended to provide power over telecommunication network.
N/A
Max. output current (A) ......................................... :
Current limiting method ........................................ :
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
No cable distribution system within this equipment.
N/A
Report No. U1011006-610
Page 24 of 42
IEC/EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
7.1
General
N/A
7.2
Protection of cable distribution system service
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
persons, and users of other equipment connected
to the system, from hazardous voltages in the
equipment
N/A
7.3
Protection of equipment users from overvoltages on
the cable distribution system
the cable distribution system
N/A
7.4
Insulation between primary circuits and cable
distribution systems
distribution systems
N/A
7.4.1
General
N/A
7.4.2
Voltage surge test
N/A
7.4.3
Impulse test
N/A