Report No. U1011006-610
 
Page 21 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
4.6.5 
Adhesives for constructional purposes 
No such consideration. 
N/A 
 
Conditioning temperature (°C), time (weeks) ........ : 
Same as above. 
 
 
4.7 
Resistance to fire 
4.7.1 
Reducing the risk of ignition and spread of flame 
Use of materials with the 
required flammability classes. 
 
Method 1, selection and application of components 
wiring and materials 
Method 1 used. 
 
Method 2, application of all of simulated fault 
condition tests 
Same as above. 
N/A 
4.7.2 
Conditions for a fire enclosure 
See below. 
4.7.2.1 
Parts requiring a fire enclosure 
See below. 
N/A 
4.7.2.2 
Parts not requiring a fire enclosure 
The appliance with: Supply of 
components in the secondary 
circuit by a limited power 
source power adaptor. The 
components are mounted on 
PCB material of flammability 
rating V-1 min. The fire 
enclosure construction is not 
required. 
4.7.3 
Materials 
See below. 
4.7.3.1 
General 
PCB rated accordingly. For 
details see table 1.5.1. 
4.7.3.2 
Materials for fire enclosures 
See sub-clause 4.7.2.2. 
The fire enclosure is not 
required. 
N/A 
4.7.3.3 
Materials for components and other parts outside 
fire enclosures 
Same as above. 
N/A 
4.7.3.4 
Materials for components and other parts inside fire 
enclosures 
Same as above. 
N/A 
4.7.3.5 
Materials for air filter assemblies 
No air filter assemblies. 
N/A 
4.7.3.6 
Materials used in high-voltage components 
No high voltage component. 
N/A 
 
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 
Class III equipment without TNV circuit. 
5.1 
Touch current and protective conductor current 
N/A 
5.1.1 
General 
 
N/A 
5.1.2 
Configuration of equipment under test (EUT) 
 
N/A 
5.1.2.1 
Single connection to an a.c. mains supply 
 
N/A 
5.1.2.2 
Redundant multiple connections to an a.c. mains 
supply 
 
N/A 
5.1.2.3 
Simultaneous multiple connections to an a.c. mains 
supply 
 
N/A 
Report No. U1011006-610
 
Page 22 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
5.1.3 
Test circuit 
 
N/A 
5.1.4 
Application of measuring instrument 
 
N/A 
5.1.5 
Test procedure 
 
N/A 
5.1.6 
Test measurements 
 
N/A 
 
Supply voltage (V)  ................................................ : 
 
 
 
Measured touch current (mA) ............................... : 
 
 
 
Max. allowed touch current (mA)  .......................... : 
 
 
 
Measured protective conductor current (mA)  ....... : 
 
 
 
Max. allowed protective conductor current (mA) ... : 
 
 
5.1.7 
Equipment with touch current exceeding 3,5 mA 
 
N/A 
5.1.7.1 
General  ................................................................. : 
 
N/A 
5.1.7.2 
Simultaneous multiple connections to the supply 
 
N/A 
5.1.8 
Touch currents to telecommunication networks and 
cable distribution systems and from 
telecommunication networks 
 
N/A 
5.1.8.1 
Limitation of the touch current to a 
telecommunication network or to a cable 
distribution system 
 
N/A 
 
Supply voltage (V)  ................................................ : 
 
 
 
Measured touch current (mA) ............................... : 
 
 
 
Max. allowed touch current (mA)  .......................... : 
 
 
5.1.8.2 
Summation of touch currents from 
telecommunication networks 
 
N/A 
 
a) EUT with earthed telecommunication ports  ..... : 
 
N/A 
 
b) EUT whose telecommunication ports have no 
reference to protective earth 
 
N/A 
 
5.2 
Electric strength 
Class III equipment without TNV circuit 
N/A 
5.2.1 
General 
 
N/A 
5.2.2 
Test procedure  
 
N/A 
 
5.3 
Abnormal operating and fault conditions 
5.3.1 
Protection against overload and abnormal operation  Ventilation openings blocked 
test performed, result see 
appended table 5.3. 
5.3.2 
Motors 
No motors provided 
N/A 
5.3.3 
Transformers 
No safety isolation 
transformer in this equipment. 
N/A 
5.3.4 
Functional insulation .............................................. : 
Method c).  
See appended table 5.3. 
Report No. U1011006-610
 
Page 23 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
5.3.5 
Electromechanical components 
No electromechanical 
components. 
N/A 
5.3.6 
Audio amplifiers in ITE  ......................................... : 
The test in accordance with 
4.3.4 and 4.3.5 of IEC 60065 
has been performed.  
See appended table 5.3 
N/A 
5.3.7 
Simulation of faults 
See sub-clause 5.3.4 
N/A 
5.3.8 
Unattended equipment 
None of the listed components 
provided. 
N/A 
5.3.9 
Compliance criteria for abnormal operating and 
fault conditions 
See below. 
5.3.9.1 
During the tests 
No fire occur, no emit molten 
metal, no hazardous. 
5.3.9.2 
After the tests 
Class III equipment only SELV 
inside. 
N/A 
 
CONNECTION TO TELECOMMUNICATION NETWORKS 
No telecommunication networks circuits within equipment. 
N/A 
6.1 
Protection of telecommunication network service persons, and users of other 
equipment connected to the network, from hazards in the equipment 
N/A 
6.1.1 
Protection from hazardous voltages 
N/A 
6.1.2 
Separation of the telecommunication network from earth 
N/A 
6.1.2.1 
Requirements 
 
N/A 
 
Supply voltage (V)  ................................................ : 
 
 
 
Current  in the test circuit  (mA) ............................ : 
 
 
6.1.2.2 
Exclusions  ............................................................ : 
 
N/A 
 
6.2 
Protection of equipment users from overvoltages on telecommunication networks 
N/A 
6.2.1 
Separation requirements 
 
N/A 
6.2.2 
Electric strength test procedure 
 
N/A 
6.2.2.1 
Impulse test 
 
N/A 
6.2.2.2 
Steady-state test 
 
N/A 
6.2.2.3 
Compliance criteria 
 
N/A 
 
6.3 
Protection of the telecommunication wiring system from overheating 
Not such equipment intended to provide power over telecommunication network. 
N/A 
 
Max. output current (A)  ......................................... : 
 
 
 
Current limiting method  ........................................ : 
 
 
 
CONNECTION TO CABLE DISTRIBUTION SYSTEMS 
No cable distribution system within this equipment. 
N/A 
Report No. U1011006-610
 
Page 24 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
7.1 
General 
 
N/A 
7.2 
Protection of cable distribution system service 
persons, and users of other equipment connected 
to the system, from hazardous voltages in the 
equipment 
 
N/A 
7.3 
Protection of equipment users from overvoltages on 
the cable distribution system 
 
N/A 
7.4 
Insulation between primary circuits and cable 
distribution systems 
 
N/A 
7.4.1 
General 
 
N/A 
7.4.2 
Voltage surge test 
 
N/A 
7.4.3 
Impulse test 
 
N/A 
 
Page of 62