JBL ON AIR WIRELESS (serv.man2) EMC - CB Certificate ▷ View online

Report No. U1011006-610
 
Page 13 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
2.8.7.3 
Endurance test 
 
N/A 
2.8.7.4 
Electric strength test  
 
N/A 
2.8.8 
Mechanical actuators 
 
N/A 
 
2.9 
Electrical insulation 
2.9.1 
Properties of insulating materials 
The equipment is power 
supplied from the power 
adaptor which is complied with 
the requirement of Limited 
Power Source. No risk of 
electrical shock or energy 
hazards. 
N/A 
2.9.2 
Humidity conditioning 
 
N/A 
 
Relative humidity (%), temperature (°C)  ................ : 
 
 
2.9.3 
Grade of insulation 
Functional insulation. 
2.9.4 
Separation from hazardous voltages 
See below. 
N/A 
 
Method(s) used  ..................................................... : 
Class III equipment, which is 
separated from hazardous 
voltage by double / reinforced 
insulation through external 
adaptor. 
 
 
2.10 
Clearances, creepage distances and distances through insulation 
2.10.1 
General  
Functional insulation only. 
2.10.1.1 
Frequency  .............................................................. :   
N/A 
2.10.1.2 
Pollution degrees  ................................................... :   
N/A 
2.10.1.3 
Reduced values for functional insualtion 
 
N/A 
2.10.1.4 
Intervening unconnected conductive parts 
 
N/A 
2.10.1.5 
Insulation with varying dimensions 
 
N/A 
2.10.1.6 
Special separation requirements 
 
N/A 
2.10.1.7 
Insulation in circuits generating starting pulses 
 
N/A 
2.10.2 
Determination of working voltage 
 
N/A 
2.10.2.1 
General 
 
N/A 
2.10.2.2 
RMS working voltage 
 
N/A 
2.10.2.3 
Peak working voltage 
 
N/A 
2.10.3 
Clearances 
 
N/A 
2.10.3.1 
General 
 
N/A 
2.10.3.2 
Mains transient voltages 
 
N/A 
 
a) AC mains supply  ............................................... :   
N/A 
 
b) Earthed d.c. mains supplies  .............................. :   
N/A 
 
c) Unearthed d.c. mains supplies  .......................... :   
N/A 
Report No. U1011006-610
 
Page 14 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
 
d) Battery operation  ............................................... :   
N/A 
2.10.3.3 
Clearances in primary circuits 
 
N/A 
2.10.3.4 
Clearances in secondary circuits 
 
N/A 
2.10.3.5 
Clearances in circuits having starting pulses 
 
N/A 
2.10.3.6 
Transients from a.c. mains supply  ........................ :   
N/A 
2.10.3.7 
Transients from d.c. mains supply  ........................ :   
N/A 
2.10.3.8 
Transients from telecommunication networks and 
cable distribution systems  ..................................... : 
 
N/A 
2.10.3.9 
Measurement of transient voltage levels 
 
N/A 
 
a) Transients from a mains suplply 
 
N/A 
 
For an a.c. mains supply  ....................................... :   
N/A 
 
For a d.c. mains supply  ......................................... :   
N/A 
 
b) Transients from a telecommunication network : 
 
N/A 
2.10.4 
Creepage distances 
 
N/A 
2.10.4.1 
General 
 
N/A 
2.10.4.2 
Material group and caomparative tracking index 
 
N/A 
 
CTI tests ................................................................. :   
 
2.10.4.3 
Minimum creepage distances 
 
N/A 
2.10.5 
Solid insulation 
 
N/A 
2.10.5.1 
General 
 
N/A 
2.10.5.2 
Distances through insulation 
 
N/A 
2.10.5.3 
Insulating compound as solid insulation 
 
N/A 
2.10.5.4 
Semiconductor devices 
 
N/A 
2.10.5.5. 
Cemented joints 
 
N/A 
2.10.5.6 
Thin sheet material – General 
 
N/A 
2.10.5.7 
Separable thin sheet material 
 
N/A 
 
Number of layers (pcs) ........................................... :   
 
2.10.5.8 
Non-separable thin sheet material 
 
N/A 
2.10.5.9 
Thin sheet material – standard test procedure 
 
N/A 
 
Electric strength test 
 
 
2.10.5.10 
Thin sheet material – alternative test procedure 
 
N/A 
 
Electric strength test 
 
 
2.10.5.11 
Insulation in wound components 
 
N/A 
2.10.5.12 
Wire in wound components 
 
N/A 
 
Working voltage ..................................................... :   
N/A 
 
a) Basic insulation not under stress  ...................... :   
N/A 
 
b) Basic, supplemetary, reinforced insulation  ........ :   
N/A 
Report No. U1011006-610
 
Page 15 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
 
c) Compliance with Annex U  ................................. :   
N/A 
 
Two wires in contact inside wound component; 
angle between 45° and 90°  ................................... : 
 
N/A 
2.10.5.13 
Wire with solvent-based enamel in wound 
components 
 
N/A 
 
Electric strength test 
 
 
 
Routine test  
 
N/A 
2.10.5.14 
Additional insulation in wound components 
 
N/A 
 
Working voltage ..................................................... :   
N/A 
 
- Basic insulation not under stress  ........................ :   
N/A 
 
- Supplemetary, reinforced insulation  .................... :   
N/A 
2.10.6 
Construction of printed boards 
 
N/A 
2.10.6.1 
Uncoated printed boards 
 
N/A 
2.10.6.2 
Coated printed boards 
 
N/A 
2.10.6.3 
Insulation between conductors on the same inner 
surface of a printed board 
 
N/A 
2.10.6.4 
Insulation between conductors on different layers of 
a printed board 
 
N/A 
 
Distance through insulation 
 
N/A 
 
Number of insulation layers (pcs) ........................... :   
N/A 
2.10.7 
Component external terminations 
 
N/A 
2.10.8 
Tests on coated printed boards and coated 
components 
 
N/A 
2.10.8.1 
Sample preparation and preliminary inspection 
 
N/A 
2.10.8.2 
Thermal conditioning 
 
N/A 
2.10.8.3 
Electric strength test 
 
N/A 
2.10.8.4 
Abrasion resistance test 
 
N/A 
2.10.9 
Thermal cycling 
 
N/A 
2.10.10 
Test for Pollution Degree 1 environment and 
insulating compound 
 
N/A 
2.10.11 
Tests for semiconductor devices and cemented 
joints 
 
N/A 
2.10.12 
Enclosed and sealed parts 
 
N/A 
 
WIRING, CONNECTIONS AND SUPPLY 
3.1 
General 
3.1.1 
Current rating and overcurrent protection 
All internal wires are UL 
recognized. Cross-sectional 
area of internal wiring is 
suitable for current intended to 
be carried. 
Report No. U1011006-610
 
Page 16 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
3.1.2 
Protection against mechanical damage 
Wires do not touch sharp 
edges or heat sinks, which 
could damage insulation and 
cause hazard. 
3.1.3 
Securing of internal wiring 
3.1.4 
Insulation of conductors 
Insulation of the conductor is 
suitable for the application. 
For insulation material see 
sub-clause 3.1.1. 
3.1.5 
Beads and ceramic insulators 
Not used. 
N/A 
3.1.6 
Screws for electrical contact pressure 
No such screws provided. 
N/A 
3.1.7 
Insulating materials in electrical connections 
All connections are metal to 
metal. 
N/A 
3.1.8 
Self-tapping and spaced thread screws 
No self-tapping screws are 
used. 
N/A 
3.1.9 
Termination of conductors 
Class III equipment without 
TNV circuit. 
N/A 
 
10 N pull test 
Same as above. 
N/A 
3.1.10 
Sleeving on wiring 
No sleeving on wiring used as 
supplementary insulation. 
N/A 
 
3.2 
Connection to a mains supply 
Class III equipment. No direct connection to mains supply. 
N/A 
3.2.1 
Means of connection  
 
N/A 
3.2.1.1 
Connection to an a.c. mains supply 
 
N/A 
3.2.1.2 
Connection to a d.c. mains supply 
 
N/A 
3.2.2 
Multiple supply connections  
 
N/A 
3.2.3 
Permanently connected equipment 
 
N/A 
 
Number of conductors, diameter of cable and 
conduits (mm) ........................................................ : 
 
 
3.2.4 
Appliance inlets 
 
N/A 
3.2.5 
Power supply cords  
 
N/A 
3.2.5.1 
AC power supply cords 
 
N/A 
 
Type  ....................................................................... : 
 
 
 
Rated current (A), cross-sectional area (mm
2
),  
AWG  ...................................................................... : 
 
 
3.2.5.2 
DC power supply cords 
 
N/A 
3.2.6 
Cord anchorages and strain relief 
 
N/A 
 
Mass of equipment (kg), pull (N)   .......................... : 
 
 
 
Longitudinal displacement (mm)  ........................... : 
 
 