Report No. U1011006-610
 
Page 33 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
Annex H 
Replace the last paragraph of this annex by: 
At any point 10 cm from the surface of the OPERATOR ACCESS AREA, the dose 
rate shall not exceed 1 µSv/h (0,1 mR/h) (see NOTE). Account is taken of the 
background level. 
Replace the notes as follows: 
NOTE These values appear in Directive 96/29/Euratom. 
Delete NOTE 2. 
N/A 
Biblio-
graphy 
Additional EN standards. 
 
 
ZA 
NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR 
CORRESPONDING EUROPEAN PUBLICATIONS 
 
 
ZB 
SPECIAL NATIONAL CONDITIONS 
1.2.4.1 
In Denmark, certain types of Class I appliances (see 3.2.1.1) may be provided with 
a plug not establishing earthing conditions when inserted into Danish socket-outlets. 
N/A 
1.5.7.1 
In Finland, Norway and Sweden, resistors bridging BASIC INSULATION in 
CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in 
1.5.7.2. 
N/A 
1.5.8 
In Norway, due to the IT power system used (see annex V, Figure V.7), capacitors 
are required to be rated for the applicable line-to-line voltage (230 V). 
N/A 
1.5.9.4 
In Finland, Norway and Sweden, the third dashed sentence is applicable only to 
equipment as defined in 6.1.2.2 of this annex. 
N/A 
1.7.2.1 
In Finland, Norway and Sweden, CLASS I PLUGGABLE EQUIPMENT TYPE A 
intended for connection to other equipment or a network shall, if safety relies on 
connection to protective earth or if surge suppressors are connected between the 
network terminals and accessible parts, have a marking stating that the equipment 
must be connected to an earthed mains socket-outlet. 
The marking text in the applicable countries shall be as follows: 
In Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun 
pistorasiaan" 
In Norway: “Apparatet må tilkoples jordet stikkontakt” 
In Sweden: “Apparaten skall anslutas till jordat uttag” 
N/A 
1.7.5 
In Denmark, socket-outlets for providing power to other equipment shall be in 
accordance with the Heavy Current Regulations, Section 107-2-D1, Standard Sheet 
DK 1-3a, DK 1-5a or DK 1-7a, when used on Class I equipment. For STATIONARY 
EQUIPMENT the socket-outlet shall be in accordance with Standard Sheet DK 1-1b 
or DK 1-5a. 
N/A 
2.2.4 
In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex. 
N/A 
2.3.2 
In Finland, Norway and Sweden there are additional requirements for the 
insulation. See 6.1.2.1 and 6.1.2.2 of this annex. 
N/A 
2.3.4 
In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex. 
N/A 
2.6.3.3 
In the United Kingdom, the current rating of the circuit shall be taken as 13 A, not 
16 A. 
N/A 
Report No. U1011006-610
 
Page 34 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
2.7.1 
In the United Kingdom, to protect against excessive currents and short-circuits in 
the PRIMARY CIRCUIT of DIRECT PLUG-IN EQUIPMENT, tests according to 5.3 
shall be conducted, using an external protective device rated 30 A or 32 A. If these 
tests fail, suitable protective devices shall be included as integral parts of the 
DIRECT PLUG-IN EQUIPMENT, so that the requirements of 5.3 are met. 
N/A 
2.10.5.13 
In Finland, Norway and Sweden, there are additional requirements for the 
insulation, see 6.1.2.1 and 6.1.2.2 of this annex. 
N/A 
3.2.1.1 
In Switzerland, supply cords of equipment having a RATED CURRENT not 
exceeding 10 A shall be provided with a plug complying with SEV 1011 or IEC 
60884-1 and one of the following dimension sheets: 
SEV 6532-2.1991   Plug Type 15  
3P+N+PE  
250/400 V, 10 A  
SEV 6533-2.1991   Plug Type 11  
L+N    
250 V, 10 A 
SEV 6534-2.1991   Plug Type 12  
L+N+PE  
250 V, 10 A 
In general, EN 60309 applies for plugs for currents exceeding 10 A. However, a 16 
A plug and socket-outlet system is being introduced in Switzerland, the plugs of 
which are according to the following dimension sheets, published in February 1998: 
SEV 5932-2.1998   Plug Type 25  
3L+N+PE  
230/400 V, 16 A 
SEV 5933-2.1998   Plug Type 21  
L+N    
250 V, 16 A 
SEV 5934-2.1998   Plug Type 23  
L+N+PE  
250 V, 16 A 
N/A 
3.2.1.1 
In Denmark, supply cords of single-phase equipment having a rated current not 
exceeding13 A shall be provided with a plug according to the Heavy Current 
Regulations, Section 107-2-D1. 
CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are 
intended to be used in locations where protection against indirect contact is required 
according to the wiring rules shall be provided with a plug in accordance with 
standard sheet DK 2-1a or DK 2-5a. 
If poly-phase equipment and single-phase equipment having a RATED CURRENT 
exceeding 13 A is provided with a supply cord with a plug, this plug shall be in 
accordance with the Heavy Current Regulations, Section 107-2-D1 or EN 60309-2. 
N/A 
3.2.1.1 
In Spain, supply cords of single-phase equipment having a rated current not 
exceeding 10 A shall be provided with a plug according to UNE 20315:1994. 
Supply cords of single-phase equipment having a rated current not exceeding 2,5 A 
shall be provided with a plug according to UNE-EN 50075:1993. 
CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are 
intended to be used in locations where protection against indirect contact is required 
according to the wiring rules, shall be provided with a plug in accordance with 
standard UNE 20315:1994. 
If poly-phase equipment is provided with a supply cord with a plug, this plug shall be 
in accordance with UNE-EN 60309-2. 
N/A 
3.2.1.1 
In the United Kingdom, apparatus which is fitted with a flexible cable or cord and is 
designed to be connected to a mains socket conforming to BS 1363 by means of 
that flexible cable or cord and plug, shall be fitted with a ‘standard plug’ in 
accordance with Statutory Instrument 1768:1994 - The Plugs and Sockets etc. 
(Safety) Regulations 1994, unless exempted by those regulations. 
NOTE ‘Standard plug’ is defined in SI 1768:1994 and essentially means an approved plug 
conforming to BS 1363 or an approved conversion plug. 
N/A 
Report No. U1011006-610
 
Page 35 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
3.2.1.1 
In Ireland, apparatus which is fitted with a flexible cable or cord and is designed to 
be connected to a mains socket conforming to I.S. 411 by means of that flexible 
cable or cord and plug, shall be fitted with a 13 A plug in accordance with Statutory 
Instrument 525:1997 - National Standards Authority of Ireland (section 28) (13 A 
Plugs and Conversion Adaptors for Domestic Use) Regulations 1997. 
N/A 
3.2.4 
In Switzerland, for requirements see 3.2.1.1 of this annex. 
N/A 
3.2.5.1 
In the United Kingdom, a power supply cord with conductor of 1,25 mm2 is 
allowed for equipment with a rated current over 10 A and up to and including 13 A. 
N/A 
3.3.4 
In the United Kingdom, the range of conductor sizes of flexible cords to be 
accepted by terminals for equipment with a RATED CURRENT of over 10 A up to 
and including 13 A is: 
• 1,25 mm
2
 to 1,5 mm
2
 nominal cross-sectional area. 
N/A 
4.3.6 
In the United Kingdom, the torque test is performed using a socket outlet 
complying with BS 1363 part 1:1995, including Amendment 1:1997 and Amendment 
2:2003 and the plug part of DIRECT PLUG-IN EQUIPMENT shall be assessed to 
BS 1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.13, 12.16 and 12.17, 
except that the test of 12.17 is performed at not less than 125 °C. Where the metal 
earth pin is replaced by an Insulated Shutter Opening Device (ISOD), the 
requirements of clauses 22.2 and 23 also apply. 
N/A 
4.3.6 
In Ireland, DIRECT PLUG-IN EQUIPMENT is known as plug similar devices. Such 
devices shall comply with Statutory Instrument 526:1997 - National Standards 
Authority of Ireland (Section 28) (Electrical plugs, plug similar devices and sockets 
for domestic use) Regulations, 1997. 
N/A 
5.1.7.1 
In Finland, Norway and Sweden TOUCH CURRENT measurement results 
exceeding 3,5 mA r.m.s. are permitted only for the following equipment: 
• STATIONARY PLUGGABLE EQUIPMENT TYPE A that  
 
○ 
is intended to be used in a RESTRICTED ACCESS LOCATION where 
 
 
equipotential bonding has been applied, for example, in a  
 
 
telecommunication centre; and 
 
○ 
has provision for a permanently connected PROTECTIVE EARTHING  
 
 
CONDUCTOR; and 
 
○ 
is provided with instructions for the installation of that conductor by a 
 
 
SERVICE PERSON; 
• STATIONARY PLUGGABLE EQUIPMENT TYPE B; 
• STATIONARY PERMANENTLY CONNECTED EQUIPMENT. 
N/A 
Report No. U1011006-610
 
Page 36 of 42 
 
IEC/EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IECEN60950_1C 
 
6.1.2.1 
In Finland, Norway and Sweden, add the following text between the first and 
second paragraph of the compliance clause: 
If this insulation is solid, including insulation forming part of a component, it shall at 
least consist of either 
two layers of thin sheet material, each of which shall pass the electric  
 
strength test below, or 
one layer having a distance through insulation of at least 0,4 mm, which shall  
 
pass the electric strength test below. 
If this insulation forms part of a semiconductor component (e.g. an optocoupler), 
there is no distance through insulation requirement for the insulation consisting of 
an insulating compound completely filling the casing, so that CLEARANCES and 
CREEPAGE DISTANCES do not exist, if the component passes the electric 
strength test in accordance with the compliance clause below and in addition 
passes the tests and inspection criteria of 2.10.11 with an electric strength  
 
test of 1,5 kV multiplied by 1,6 (the electric strength test of 2.10.10 shall be  
 
performed using 1,5 kV), and 
is subject to ROUTINE TESTING for electric strength during manufacturing,  
 
using a test voltage of 1,5 kV. 
It is permitted to bridge this insulation with a capacitor complying with 
EN 132400:1994, subclass Y2. 
A capacitor classified Y3 according to EN 132400:1994, may bridge this insulation 
under the following conditions: 
the insulation requirements are satisfied by having a capacitor classified Y3  
 
as defined by EN 132400, which in addition to the Y3 testing, is tested with  
 
an impulse test of 2,5 kV defined in EN 60950-1:2006, 6.2.2.1; 
the additional testing shall be performed on all the test specimens as  
 
described in EN 132400; 
the impulse test of 2,5 kV is to be performed before the endurance test in 
 
EN 132400, in the sequence of tests as described in EN 132400. 
N/A 
6.1.2.2 
In Finland, Norway and Sweden, the exclusions are applicable for 
PERMANENTLY CONNECTED EQUIPMENT, PLUGGABLE EQUIPMENT TYPE B 
and equipment intended to be used in a RESTRICTED ACCESS LOCATION where 
equipotential bonding has been applied, e.g. in a telecommunication centre, and 
which has provision for a permanently connected PROTECTIVE EARTHING 
CONDUCTOR and is provided with instructions for the installation of that conductor 
by a SERVICE PERSON. 
N/A 
7.2 
In Finland, Norway and Sweden, for requirements see 6.1.2.1 and 6.1.2.2 of this 
annex. 
The term TELECOMMUNICATION NETWORK in 6.1.2 being replaced by the term 
CABLE DISTRIBUTION SYSTEM. 
N/A 
7.3 
In Norway and Sweden, there are many buildings where the screen of the coaxial 
cable is normally not connected to the earth in the building installation. 
N/A 
7.3 
In Norway, for installation conditions see EN 60728-11:2005. 
N/A 
 
ZC 