JBL ESC Xcite EMC - CB Certificate ▷ View online
page 1 of 34
Ref. No.:408507
TEST REPORT
IEC 60065
Audio, video and similar apparatus
Safety requirements
Report
Reference No. ................................... : 408507
Tested by (+ signature) ..................... : Sven-Olov Lundsjö
.......................................................
Approved by (+ signature)................. :
Kjell Fredriksson
.......................................................
Date of issue ..................................... : 4 August 2004
Contents............................................ : See below.
Testing laboratory
Name................................................. : Intertek Semko AB
Address ............................................. : P.O. Box 1103, SE-164 22, Kista, SWEDEN
Testing location ................................. : Torshamnsgatan 43, Kista, SWEDEN
Client
Name................................................. : HARMAN CONSUMER GROUP
Address ............................................. : 250 Crossways Park Drive Woodbury, NY 11797-2015, USA
Test specification
Standard............................................ : IEC 60065:1998, Group differences and for the CENELEC
countries ( EN 60065 )
Test procedure ................................. : CB-scheme
Procedure deviation .......................... : N.A.
Non-standard test method ................ : N.A.
Test Report Form/blank test report
Test Report Form No. ....................... : 60065__C/99-02
Master TRF ....................................... : Reference No. 60065, dated 98-12
Page 1- 26
IEC 60065 Test Report.
Page 27-31
Group differences and for the CENELEC countries.
Page 32-33
National differences for Singapore.
Page 34
National differences for Korea.
6 photo pages enclosed.
page 2 of 34
Ref. No.:408507
Test item
Description ........................................ : 6-channel active subwoofer
Trademark......................................... :
Model and/or type reference ............. : esc xcite
Manufacturer ..................................... : HARMAN CONSUMER GROUP
Rating(s)............................................ : 220 – 240V , 50/60Hz, 400W, Class
ΙΙ
Test case verdicts
Test case does not apply to the test object..................: N (Not Applicable)
Test item does meet the requirement ..........................: P (Pass)
Test item does not meet the requirement ....................: F (Fail)
Testing
Date of receipt of test item ..........................................: -
Date(s) of performance of test .....................................: -
General remarks
“This report is not valid as a CB Test Report unless appended to a CB Test Certificate issued by a NCB, in
accordance with IECEE 02”.
accordance with IECEE 02”.
This test report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item tested.
“(see remark #)” refers to a remark appended to the report.
“(see appended table)” refers to a table appended to the report.
Throughout this report a point is used as the decimal separator.
page 3 of 34
Ref. No.:408507
Copy of marking plate
Note: This Test Report is based on the test report for model ESC360, ref No. 204743. The differences
between the models are:
- the model name of main unit and speakers,
- the art work of rear panel, remote control, speaker labels, owners manual and beauty box,
- the high frequency speaker component is changed from dome tweeter to piezo tweeter.
between the models are:
- the model name of main unit and speakers,
- the art work of rear panel, remote control, speaker labels, owners manual and beauty box,
- the high frequency speaker component is changed from dome tweeter to piezo tweeter.
page 4 of 34
Ref. No.:408507
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................ : Class
ΙΙ
P
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test
box
box
No Noted
5 MARKING
Comprehensible and easily discernible
P
Permanent durability against water and petroleum
spirit
spirit
P
5.1
Identification, maker, model .................................. :
,
esc xcite
P
Class
ΙΙ symbol
P
Rated supply voltage and symbol ......................... : 220 – 240V , 50/60Hz
P
Rated current or power consumption .................... : 400W
N
5.2 Earth
terminal
N
Hazardous live terminals
N
Supply output terminals (other than mains)
N
5.3
Use of triangle with exclamation mark
Only in schematic diagram.
P
5.4
Instructions for use
5.4.1
Mains powered equipment not exposed to dripping
or splashing
or splashing
P
Hazardous live terminals, instructions for wiring
N
Instructions for replacing lithium battery
In the user and service manual
instructions.
instructions.
P
Explanation of marking of the manually operated
mechanical switch (MOMS)
mechanical switch (MOMS)
P
5.4.2
Instructions for permanently connected equipment
N
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation
≤ 36 pA/kg (0.5 mR/h)
N
6.2
Laser radiation, emission limits to IEC 60825 ....... :
N
Emission limits under fault conditions
N