DOWNLOAD JBL ESC Xcite Service Manual ↓ Size: 1.85 MB | Pages: 46 in PDF or view online for FREE

Model
ESC Xcite
Pages
46
Size
1.85 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
esc-xcite.pdf
Date

JBL ESC Xcite EMC - CB Certificate ▷ View online

 
 
page 21 of 34 
Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
 N 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 N 
A.10.2.2 
Humidity treatment carried out for 7 days 
 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
 
B.5.4.1 
e) Where the separation of TNV circuits from other 
circuits relies on protective earthing the 
instructions make it clear that protective earthing is 
essential 
 N 
B.8.1 
TNV circuits separated from the mains circuit and from hazardous live parts by either: 
 
 
a) double or reinforced insulation 
 
 
b) basic insulation with earthed protective 
screening 
 N 
B.8.2 
TNV circuits separated from circuits other than 
those in B.8.1 and from accessible conductive 
parts by basic insulation meeting the requirements 
for clearances and creepage distances for the 
voltages concerned 
 N 
B.9.1.1 
TNV circuit terminals contacts which cannot be 
touched by probe B.1, exempt from the 
requirements inaccessible terminal contacts in 
9.1.1 
 N 
B.10.1 
Insulation between TNV terminals and antenna 
terminals (including interconnection terminals 
which may be connected to equipment with 
antenna terminals) withstands the 50 discharges of 
10.1 
 N 
B.14.12 
Surge suppressors between TNV circuits and 
other parts of the equipment have breakdown 
voltage at least 1.8 times the mains voltage 
 N 
 
 
 
 
page 22 of 34 
Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
 
 
 
position of the functional switch (W) ...................... : 0 / 46  
 
Operating conditions 
Un = 254.4V. Pro Logic surround mode. Input aux, one–eight of max. non – clipping output power (pink noise) 
according to sub-clause 4.1.6. 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
254.4 
198 
0.45 
0.38 
80 
55 
Front 2 x 0.72 
Center 2 x 0.25 
Surround 2 x 0.17 
Subwoofer 7.5 
 
Loudspeaker impedance (
Ω) ................................ : Front, Center, Surround = 4 
Subwoofer = 5.3 
 
 
Several loudspeaker systems 
Left and Right for Front, 
Center, Surround and Subw. 
 
 
Marking of loudspeaker terminals 
Left and Right for Front, 
Center, Surround. 
 
monitored point: 
dT (K) 
Permitted dT (K) 
1. Supply wiring insulation (not under mechanical stress) 
19 
60 (50) 
2. Mains switch (plastic) 
10 
50 (40)  
3. Iron core Transformer T1 
37 
4. PCB 
32 
85 (75) 
5. Rear enclosure (metallic) near mains switch   
24 
40 (30) 
6. Heat sink (metallic) near mains switch   
26 
40 (30) 
7. Heat sink (metallic).    
28 
40 (30) 
8. Wooden enclosure. 
13 
60 (50) 
9. Front panel (plastic) 
60 (50) 
Values in parenthesis are for tropical climate. 
 
 
page 23 of 34 
Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
7.1 
TABLE: temperature rise measurements 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (ºC)  ................................. : 21 
 
 
Ambient temperature t2 (
°C) ................................. : 22 
 
temperature rise dT of winding: 
R
1
 (
Ω) 
R
2
 (
Ω) 
dT (K) 
permitted 
dT (K) 
insulation 
class 
Transformer T1  Prim. 
5.590 
6.490 
41 
85 
 
 
Sec. 1 (white - white ) 
0.254 
0.292 
39 
85 
 
 
Sec. 2 (yellow – yellow) 
1.846 
2.110 
37 
85 
 
 
Sec. 3 (red – red) 
0.392 
0.449 
37 
85 
 
 
Sec. 1 (blue– blue) 
0.915 
1.054 
39 
85 
 
7.2 
TABLE: softening temperature of thermoplastics 
temperature T of part 
T - normal  
conditions (ºC) 
T - fault  
conditions (ºC) 
T softening 
(ºC) 
 
 
 
 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
Insulation resistance R between… 
R (M
Ω) 
required R (M
Ω) 
… parts of different polarity directly connected to the mains. 
> 100 
Min. 2 
… parts separated by reinforced insulation. 
> 100 
Min. 4 
 
10.3 TABLE: 
electric 
strength 
measurements 
Test voltage applied between… 
test voltage (V) 
Breakdown 
… parts of different polarity directly connected to the mains. 
2120V peak 
No 
… parts separated by reinforced insulation. 
4240V peak 
No 
 
 
 
page 24 of 34 
Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0.9 or 1.06 times rated voltage  .......... : 220 - 240 
 
 
Ambient temperature (
°C) ..................................... : 24 
 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (ºC)  ................................. : 22 
 
 
Ambient temperature t2 (ºC)  ................................. : 24 
 
No.  Component 
No. 
Fault 
Test voltage 
 (V) 
Test  
time 
Fuse No.
Fuse  
current
(A) 
Result 
Sc = short circuit,  dis = disconnection 
1 Mode: 
Prologic 
Surround 
100% 
output 
254.4 4 
F901/2
F903/4
F905 
F906/7 
5.0 
0.5 
0.8 
1.7 
Pin = 217W, In = 1.1A 
After 4 h following rise temperatures 
were measured: Transformer T1 
Prim. winding dT = 73K 
Sec. windings dT = 65 – 68K 
Rear side (metallic) dT = 30K 
PCB dT = 35K 
No remarks. 
2 BD901 
(+ - –) 
sc 
198 / 254.4 
F901/2 
> 16.8  Fuses 
F901 / F902
 blew immediately
No hazard.  
3 BD901 
(+ -  ) 
sc 198  - 
F901 
16.8 
Fuse 
F901
 blew immediately. 
No hazard.  
4 BD901 
(+ -  ) 
sc 
254.4 
F901/2 
> 16.8  See fault No. 2 
5 BD902 
(+ - –) 
sc 
198 / 254.4 
F901/2 
> 16.8  Fuses 
F901 / F902
 blew immediately
No hazard.  
6 BD902 
(+ -  ) 
sc 
198 / 254.4 
10 min.
F901 
> 16.8  Fuse 
F901
 blew immediately. 
Apparatus in the standby mode 
after 5s will apparatus start up and 
down mode. No hazard.  
7 BD903 
(+ - –) 
sc 
198 / 254.4 
F905 
> 4.2  Fuses 
F905
 blew immediately. 
No hazard.  
8 BD903 
(+ -  ) 
sc 
198 / 254.4 
F905 
> 4.2  See fault No. 7 
9 BD904 
(+ - –) 
sc 
198 / 254.4 
F906/7 
> 8.4  Fuses 
F906 / F907 
blew immediately
No hazard.  
10 BD904 
(+ -  ) 
sc 
198 / 254.4 
F906 
> 8.4  Fuses 
F906
 blew immediately. 
No hazard.  
 
Page of 46
Display