JBL ESC Xcite EMC - CB Certificate ▷ View online
page 13 of 34
Ref. No.:408507
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14.6
Switches
(See list of critical components)
14.6.1 Permanently
connected
equipment
provided
with
an all-pole mains switch unless 5.4.2 is met
N
14.6.2
Manually operated mechanical switch (MOMS),
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required ................... :
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required ................... :
No, “ timer “ function
N
Switch readily accessible and not in mains cord
N
Exception
for
automatic
switching
Yes
P
Exception for continuous operation
N
14.6.3
Manually operated mechanical switch (MOMS):
switch indication On position clearly discernible
switch indication On position clearly discernible
ON N
Indication by marking meets Cl. 5
AC POWER
N
Indication
of
the
OFF
position
OFF
N
14.6.4
Manually operated mechanical switch (MOMS)
fitted, is there a Stand-by mode ............................ :
fitted, is there a Stand-by mode ............................ :
No N
Stand-by mode clearly discernible ........................ :
N
Exception for low Stand-by current < 0.7 mA
(peak)
(peak)
N
14.6.5
Components bridging contacts of mains switches
comply with 14.1 a) or 14.2.2
comply with 14.1 a) or 14.2.2
C1 P
14.6.6
Manually operated mechanical switches (MOMS)
separately approved to IEC 61058-1
separately approved to IEC 61058-1
SW 1
(Peak surge current = 36A)
(Peak surge current = 36A)
P
Manually operated mechanical switch (MOMS)
tested as part of the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
tested as part of the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
N
14.7
Safety interlocks
Safety interlocks to 2.8 of IEC 60950
N
14.8
Voltage setting devices
Voltage setting device not likely to be changed
accidentally
accidentally
N
page 14 of 34
Ref. No.:408507
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14.9
Motors
14.9.1
Endurance test on motors
N
Motor
start
test
N
Dielectric
strength
test
N
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet Cl. B.8, B.9 and
B.10 of IEC 60950, Annex B
motors and series motors meet Cl. B.8, B.9 and
B.10 of IEC 60950, Annex B
N
14.10
Batteries
(See list of critical components)
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
No connection if the battery is
turned the wrong way.
turned the wrong way.
P
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
No recharging.
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
Battery UL – rec.
(Short circuit test included).
(Short circuit test included).
P
14.11
Optocouplers
Optocouplers comply with Cl. 8
N
N
page 15 of 34
Ref. No.:408507
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
15 TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
See list of critical components
P
15.1.2
Connectors for antenna, earth, audio, video or data:
No risk of insertion in mains socket-outlets
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
N
15.1.3
Output terminals of AC adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
N
15.2
Provision for protective earthing
Accessible conductive parts of Class
Ι equipment
reliably connected to earth terminal, within
equipment
equipment
N
Class
Ι supply equipment with non-hazardous live
output voltage: output circuit not connected to
earth
earth
N
Protective earth conductors correctly coloured
N
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N
Protective earth terminal resistant to corrosion
N
Earth resistance (
Ω) ≤ 0.1 Ω at 25 A ..................... : N
page 16 of 34
Ref. No.:408507
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
15.3
Terminals for external flexible cords and for permanent connection to the mains supply
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N
15.3.2 Reliable
connection
of
non-detachable
cords:
not soldered to conductors of a printed circuit
board
board
No P
adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
All well fixed in a bundle tie.
P
wire secured by additional means to the conductor
P
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
P
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
Clamping in a so called “bell
connector”
connector”
P
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
sectional area of conductors, for the rated current
of the equipment
N
15.3.6
Terminals to 15.3.3 have sizes required by Table 8
N
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
N
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N
15.3.8
Terminals carrying a current more than 0.2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N
15.3.9 Termination
of
non-detachable
cords:
wires
terminated near to each other
P
Terminals located and shielded: test with 8 mm
strand
strand
P
15.4
Devices forming a part of the mains plug
15.4.1
No undue strain on mains socket-outlets
N
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N
Click on the first or last page to see other ESC Xcite service manuals if exist.