JBL ESC Xcite EMC - CB Certificate ▷ View online
page 25 of 34
Ref. No.:408507
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
No. Component
No.
Fault
Test voltage
(V)
Test
time
Fuse No.
Fuse
current
(A)
Result
11 IC703
(Pin 3 - 5)
sc
254.4
11 min.
F906/7
6.2A
Pn = 370W, In = 1.7A.
After 11 min. IC703 damage.
No hazard.
After 11 min. IC703 damage.
No hazard.
12 IC703
(Pin 5 - 11)
sc
254.4
10 min.
F906/7
0.9
Pn = 80W, In = 0.45A.
Nothing happened, normal power.
No remarks.
Nothing happened, normal power.
No remarks.
13 IC703
(Pin 5 - 7)
sc 254.4 -
F906/7
>8.4A
Fuses
F905
blew immediately.
No hazard.
14 IC901
(Pin 1 – 2)
sc
198 / 254.4
20 min.
F901/2
F903/4
F903/4
F905
F906/7
0.5
0.5
0.8
0.2
0.5
0.8
0.2
Pn=70 → 58W, In = 0.34 → 0.30A.
Black display, less power output.
No high temp.
No hazard.
Black display, less power output.
No high temp.
No hazard.
15 IC902
(Pin 1 – 2)
sc
198 / 254.4
20 min.
F901/2
F903/4
F903/4
F905
F906/7
0.5
2 → 1.4
0.7
0.2
0.2
Pn=70 → 58W, In = 0.34 → 0.30A.
Less power output, no high temp.
No hazard.
Less power output, no high temp.
No hazard.
16 IC904
(Pin 1 – 2)
sc
198 / 254.4
20 min.
F901/2
F903/4
F903/4
F905
F906/7
0.5
0.5
0.8
0.2
0.5
0.8
0.2
Pn=63W, In = 0.30A.
Black display, only ON light.
Less power output, no high temp.
No hazard.
Black display, only ON light.
Less power output, no high temp.
No hazard.
17 Front
speaker R
output pins
sc 254.4
20
min.
F901/2
F903/4
F903/4
F905
F906/7
-
-
-
-
-
-
-
Pn=
124W
in 1min. after
600W
in 10s
In=0.63A.in 1min. after 3A in 10s
IC501 damage after 1 min. 10s
Only subw. power output, no high
temp. No hazard.
IC501 damage after 1 min. 10s
Only subw. power output, no high
temp. No hazard.
page 26 of 34
Ref. No.:408507
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
14
TABLE: list of critical components and materials
P
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
Mains switch
SW1
SW1
Chily Precision
Ind. Ltd.
3051
5 / 80A 250V
IEC 61058-1
Approved by
FIMKO
Mains capacitor
C1 across the
mains switch
C1 across the
mains switch
Carli Electronics
Co. Ltd.
MPX series
0.01
µF, 275V
X2
IEC 60384-14
2
nd
edition
Tube over fuse-
holder, switch
(plastic material)
holder, switch
(plastic material)
Shenzhen
Changbao Spec.
Plastic Prod. Co.
Plastic Prod. Co.
Changbo 102
(VW-1)
FV-0
IEC 60065
(Annex G)
Tested as a part
of the appliance
Transformer T1
DAR PLUS
TTK223001-
0001
230V, 50Hz
IEC 60065
-
Thermal cut-outs
Texas
Instruments INC
17 AM 033
-
IEC 60065
Tested as a part
of the appliance
Bobbin
(plastic material)
(plastic material)
Dupont De
Nemours Co.
Nylon 66
FV0
IEC 60065
(Annex G)
Tested as a part
of the appliance
Mains Fuse
Walter
TSD
T4AL 250V
IEC 60127
Secondary
Fuses
Fuses
F901,F902
Bel
-
T8H 250V
IEC 60065
Tested as a part
of the appliance
Secondary
Fuses F903, F904
Walter
TSD
T1.6AL 250V
IEC 60127
Secondary
Fuse F905
Fuse F905
Walter
TSD
T2AL 250V
IEC 60127
Secondary
Fuses F906, F907
Walter
TSD
T4AL 250V
IEC 60127
M-Fuse holder
ECHO EL
FH-B02
6.3A 250V
IEC 60065
PCB Dongguan
Huiho
Electronics Co.
4B-2
FV - 0
IEC 60707: 1981
-
Lithium battery
Hitachi Maxell
Ltd.
CR 2025
3V
IEC 60065
UL Rec.
Mains plug
Kenic
KE-21
2.5A 250V
CEE 7
Mains cord
H03VVH2-F or
H05VVH2-F
2 x 0.75 mm²
IEC 60227
UK: Mains plug
Winbo
MS323
3A 250V
BS 1363
BSI
Mains cord
H03VVH2-F or
H03VV-F
2 x 0.75 mm²
BS 6500
BASEC
Korea: Mains plug
Volex MP2217
3A
250V
KSC8305
Mains cord
VCTFK
2 x 0.75 mm²
KSC3304
page 27 of 34
Ref. No.:408507
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
GROUP DIFFERENCES (COMMON MODIFICATIONS) TO IEC 60065
CONTENTS
Add the following annexes:
Annex ZB (normative) Special national conditions
Annex ZC (informative) A-deviations
Noted
1.1.1
Replace the text of note 1 by:
NOTE 1 This standard can be used as a guide for
the testing of battery operated apparatus.
the testing of battery operated apparatus.
Noted
3.1 Delete
the
note.
Add the following indent:
-
Exposure to excessive sound pressures from
headphones or earphones
headphones or earphones
NOTE A new method is under consideration by
CENELEC/TC 206
CENELEC/TC 206
Noted
15.1.1
Delete notes 1 and 2.
Add to note 4:
Attention is drawn to the fact that a standard is
under preparation (presently prEN 50074) for
socket-outlets which allow connection of Class II
appliances only.
under preparation (presently prEN 50074) for
socket-outlets which allow connection of Class II
appliances only.
Noted
15.2
Delete note 2.
Noted
16.1
Delete note 1.
Noted
16.2 Delete
the
note.
Noted
20
Delete note 2.
Noted
Annex B
Delete note 2.
Noted
B.5.4.1e)
Delete notes 1 and 2.
Noted
B.8.1
Delete notes 1, 2 and 3.
Noted
B.8.2 Delete
the
note.
Noted
B.14.12
Delete notes 1 and 2.
Noted
Annex G
Delete the note.
Noted
page 28 of 34
Ref. No.:408507
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Annex P
Bibliography
Add the following notes for the standards
indicated:
indicated:
IEC 60130
NOTE: IEC 60130-9:1989 +
A1: 1993 are harmonized as EN
60130-9
(not
modified).
IEC 60169
NOTE: Parts 23, 24 and25 are
harmonized as Ens (not modified)
IEC 60173
NOTE: Harmonized as HD 27
S1: 1983 (not modified).
IEC 60260
NOTE: Harmonized as HD 98
S1: 1977 (not modified).
IEC 60335-2-56 NOTE: Harmonized as EN 60335-
2-56:1997 (not modified).
IEC 61040
NOTE: Harmonized as EN
61040:1992 (not modified).
IEC 60695
NOTE: Harmonized as EN 60695
series
(not
modified).
Noted
Click on the first or last page to see other ESC Xcite service manuals if exist.