JBL ESC Xcite EMC - CB Certificate ▷ View online

 
 
page 9 of 34 
Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
12 MECHANICAL 
STRENGTH 
 
12.1.1 
Bump test 
Weight 14 kg 
12.1.2 
Vibration test 
No connection or part, which 
might impair safety, can 
become loose.    
12.1.3 Impact 
test 
 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
12.3 
Remote controls with hazardous live parts 
 
12.4 
Drawers (pull test 50 N, 10 s) 
 
12.5 
Antenna coaxial sockets providing isolation 
 
 
13 
CLEARANCES AND CREEPAGE DISTANCES 
 
13.1 
Clearances and creepage distances in accordance 
with 13.2 (fig. 9); minimum distance  ..................... :
Fuse holder (Prim.)  – accessible 
metal part = >15 mm  
13.1.1 
Reduction applied if the 3 conditions are met  ....... : No 
 
Reduction applied for Grade 2 winding wire  ......... : No 
13.1.2 
Use of cemented joints .......................................... : No 
 
Tests to confirm cemented joints 
 
13.2 
Clearances and creepage distances of parts of 
different polarity connected to the mains, as in 
fig. 9; minimum distance  ....................................... :
5 mm 
 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 N 
13.3 
Enclosed, enveloped or hermetically sealed parts: 
clearances and creepage distances to Table 4 
 N 
13.4 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
 N 
13.5 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 N 
 
 
 
page 10 of 34 
Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
14 COMPONENTS 
 
14.1 
Resistors 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
 N 
 
a) Resistors separately approved ......................... :  
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N 
 
b) Resistors separately approved ......................... :  
14.2 
Capacitors and RC units 
 
Capacitors separately approved 
 
14.2.1 
Y capacitors tested to IEC 60384-14, 2:nd Edition  :  
14.2.2 
X capacitors tested to IEC 60384-14, 2:nd Edition : C1, X2 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ..................... :
 N 
14.2.5 
Capacitors with volume exceeding 1750 mm
3
 
where short-circuit current exceeds 0.2 A: 
compliance with IEC 60384-1, 4.38 category B or 
better ..................................................................... :
 N 
 
Capacitors with volume exceeding 1750 mm
3
mounted closer to a potential ignition source than 
Table 5 permits: compliance with IEC 60384-1, 
4.38 category B or better ....................................... :
 N 
 
Shielded by a barrier to FV 0 or metal  .................. :  
 
 
page 11 of 34 
Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
14.3 
Inductors and windings 
14.3.1 
Transformers and inductors marked with 
manufacturer’s name and type  ............................. :
Transformer T1: 
DAR PLUS, TTK223001-0001 
 
Transformers and inductors separately approved  : No 
14.3.2 
Isolating transformer complies with 14.3.3, 
14.3.4.1 or 14.3.4.2 and 14.3.5.1 or 14.3.5.2 …….:
T1: 14.3.3, 14.3.4.1, 14.3.5.1 
 
Separating transformer complies with 14.3.3, 
14.3.4.3 and 14.3.5.1 or 14.3.5.2 …….……………:
 N 
 
Flammability test of insulating material acc. to 
20.1.4 (except in thin sheet form) 
Bobbin in T1 
14.3.3.1 
Clearances and creepage distances according to 
clause 13 
 P 
14.3.3.2 
Transformers meet the constructional 
requirements 
 P 
14.3.4.1 
Class 
ΙΙ transformers have adequate separation 
between hazardous live windings and accessible 
windings (double or reinforced insulation) 
Reinforced insulation T1: 
Prim. – sec. = 15.3 mm 
 
Coil formers and partition walls 
≥ 0.4 mm 
Bobbin insulation T1: 1.5 mm 
14.3.4.2 
Class 
Ι transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
 N 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 N 
14.3.5.1 
Class 
ΙΙ transformers have adequate insulation 
between hazardous live windings and accessible 
parts (double or reinforced insulation) 
Reinforced insulation T1: 
Prim. – acc. parts = 11.4 mm 
 
Coil formers and partition walls 
≥ 0.4 mm 
Bobbin insulation T1: 1.5 mm 
14.3.5.2 
Class 
Ι transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 N 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N 
 
 
page 12 of 34 
Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
14.4 
High voltage components 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 N 
 
Component meets category FV 1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 N 
14.5 
Protective 
devices 
    
 
(See list of critical components) 
 
Protective devices used within their ratings 
 
 
External clearance and creepage distances 
appropriate for the voltage across the device when 
opened 
 P 
14.5.1.1 
a) Thermal cut-outs separately approved 
 
 
b) Thermal cut-outs tested as part of the 
submission 
Thermal Cut-out not activated 
during the tests. 
14.5.1.2 
a) Thermal links separately approved 
 
 
b) Thermal links tested as part of the submission 
 
14.5.1.3 
Thermal devices resettable by soldering 
 
14.5.2.1 
Fuse-links in the mains circuit according to 
IEC 60127 
Mains fuse  
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... : Mains fuse: T4AL,  
Secondary fuses: 
F901 and F902: T8H 
F903 and F904: T1.6AL 
F905: T2AL 
F906 and F907: T4AL 
14.5.2.3 
Not possible to connect fuses in parallel ............... :  
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ........ :
Tools are required. 
14.5.3 
PTC-S thermistors comply with IEC 60738 
 
 
PTC-S devices (15 W) category FV 1 or better 
 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
 N 
 
 
Page of 46