DOWNLOAD JBL ESC Xcite Service Manual ↓ Size: 1.85 MB | Pages: 46 in PDF or view online for FREE

Model
ESC Xcite
Pages
46
Size
1.85 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
esc-xcite.pdf
Date

JBL ESC Xcite EMC - CB Certificate ▷ View online

 
 
page 17 of 34 
Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
16 EXTERNAL 
FLEXIBLE 
CORDS 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords  .......................................................... :
PVC  
 
Non-detachable cords for Class 
Ι have 
green/yellow core for protective earth 
 N 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment 
2 x 0.75 mm² 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength 
 N 
 
b) Flexible cords not complying with 16.1, 
withstand bending and mechanical stress (3.2 of 
IEC 60227-2) 
 N 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions 
 N 
16.5 
Adequate strain relief on external flexible cords 
Strain relief bushing under 
compression 
 
Not possible to push cord back into equipment 
 
 
Strain relief device unlikely to damage flexible cord  
 
For mains cords of Class 
Ι equipment, hazardous 
live conductors become taut before earth 
conductor 
 N 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use 
 P 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet 
to IEC 60320-1 
 N 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord 
 N 
 
 
 
page 18 of 34 
Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
17 
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS 
 
17.1 
Torque test to Table 12: 
 
 
- screws into metal: 5 times 
 
 
- screws into non-metallic material: 10 times 
Diam. 4 mm,  
wood torque 1.2Nm 
17.2 Correct 
introduction 
into female threads in non-
metallic material 
Screwing 10 times into  wood 
17.3 
Cover fixing screws: captive 
 
 
Non-captive fixing screws: no hazard when 
replaced by a screw whose length is 10 times its 
diameter 
 P 
17.4 
No loosening of conductive parts carrying a current 
> 0.2 A 
 N 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0.2 A 
 N 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0.2 A with screw terminals not 
consolidated by solder 
 N 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
 N 
17.8 
Fixing devices for detachable legs or stands 
provided 
 N 
17.9 
 P 
 
 
 
page 19 of 34 
Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST 
THE EFFECTS OF IMPLOSION 
 
18.1 
Picture tube separately approved  ......................... :  
 
Picture tubes > 16 cm intrinsically protected 
 
 
Non-intrinsically protected tubes > 16 cm used 
with protective screen 
 N 
18.2 
Intrinsically protected tubes: tests on 12 samples 
 
18.2.1 
Samples subject to ageing: 6 
 
18.2.2 
Samples subject to implosion test: 6 
 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
 N 
18.3 
Non-intrinsically protected tubes tested to 18.3 
 
 
19 
STABILITY AND MECHANICAL HAZARDS 
 
 
Mass of the equipment exceeding 18 kg  .............. : No, 14 kg  
19.1 
Test on a plane, inclined at 10º to the horizontal 
 
19.2 
100 N applied vertically downwards 
 
19.3 
Smooth edges and corners 
 
19.4 
Glass surfaces with an area exceeding 0.1 m
2
 or 
maximum dimension > 450 mm, pass the test of 
19.4.1 
 N 
 
 
 
page 20 of 34 
Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
20 RESISTANCE 
TO 
FIRE 
 
20.1 
Electrical components and mechanical parts 
  (See list of critical components) 
 
 
a) Exemption for components contained in an 
enclosure of material FV 0 to IEC 60707 with 
openings not exceeding 1 mm in width 
 N 
 
b) Exemption for small components as defined in 
20.1 
 P 
20.1.1 
Electrical components meet the requirements of 
14.2.5, 14.4, 14.5.3, 14.6.6 or 20.1.4 
 P 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, not 
contributing to the spread of fire 
 N 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
FV 1 or better to IEC 60707, unless used in a fire 
enclosure 
 P 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
exceeding 400 V (peak) a.c. or d.c. meets FV 0 to 
IEC 60707 
 N 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 13 comply with the relevant 
flammability category in Table 13 
 P 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 13 and fig. 13 
 N 
20.2 
Fire enclosure 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to FV 1 
 N 
20.2.2 
 N 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
 N 
 
Page of 46
Display

Click on the first or last page to see other ESC Xcite service manuals if exist.