DOWNLOAD JBL ESC Xcite Service Manual ↓ Size: 1.85 MB | Pages: 46 in PDF or view online for FREE

Model
ESC Xcite
Pages
46
Size
1.85 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
esc-xcite.pdf
Date

JBL ESC Xcite EMC - CB Certificate ▷ View online

 
 
page 33 of 34 
Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
16.3b 
(16.4b) 
 
Delete “Subclause 3.1 of IEC Publication 60227-2: Part 2: 
Test Methods“ and insert “Subclause 9.1 of SS 236“: 
9.1 Flexing test (except for tinsel cords, twisted twin and 
single core cords). The test shall be carried out  by means of 
the apparatus shown in Figure 5. This apparatus has a 
carrier C supporting two pulleys A and B arranged so that 
the cord is horizontal between the pulleys. The carrier 
moves backward and forward over a distance of 1 m at an 
approximately constant speed of 0.33 m/s.                
A sample of flexible cord about 5 m long shall be stretched 
over the pulleys as shown in the figure, each end being 
loaded with a weight. The weight and the diameter of the 
pulleys A and B shall be given in Table 1. 
Screene cords in accordance with Table 7 shall be tested 
before application of the screen and outer sheath.                 
The pulleys shall have a semi-circular shaped groove for 
circular cords and a flat groove for parallel twin cords. The 
restraining clamps D shall be fixed so that the pull is 
always applied by the weight from which the carrier is 
moving away. The carrier shall make 30 000 backward and 
forward movements (60 000 single strokes). Each 
conductor of the sample shall be loaded with the current 
specified in Table 2.                                
For twin cords and for light PVC-sheated 3-core cords, the 
voltage between the conductors shall be approximately 230 
V a.c. For all other cords having three or more cores a 
three-phase a.c. voltage of about 400 V shall be applied to 
three conductors, any additional conductors being 
connected to the neutral.                                
During the test no open-circuit in any core or short-circuit 
between cores shall occur.                                                  
After the test, any sheath on cords having three or more 
cores shall be removed. The cord, or the laid up cores, 
shall then withstand the voltage test specified in Subclause 
8.2 or 8.3 as appropriate, but with a test voltage not 
exceeding 2000 V. 
TABLE 1, TABLE 2, FIGURES 4 and  5, see the           
CB BULLETIN 
 Noted 
 
* in parenthesis: clauses acc. to IEC 60065:1993 
 
 
 
 
 
 
page 34 of 34 
Ref. No.:408507  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
National differences  KOREA 
IEC 60065:1998 
 
CB Bulletin 105A / KR 03 I 
 
 
5.101 Addition 
Other marking; 
Wording “            “ ( See the CB Bulletine) or an 
information regulated in IEC Publication 60417 
giving high voltage warning to layman shall be 
marked, if an apparatus contains a part more 
than 600 volts. 
 
Noted 
15.1.1 
Plugs for the connection of the apparatus to the 
supply mains and socket outlets for providing 
mains power to other apparatus shall comply with 
the Korean requirements (KSC 8300 and 8305). 
 P 
31 Radio 
frequency 
Interference 
The apparatus shall comply with the relevant 
CISPR requirements. (EMC=EMI + EMS) 
 
Not 
checked 
 
 
408507
408507
408507
408507
408507
408507
Page of 46
Display

Click on the first or last page to see other ESC Xcite service manuals if exist.