JBL ES 150PW (serv.man5) EMC - CB Certificate ▷ View online
Page 26 of 58
Report No.: 1009950
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Transmitter JBLSUBTX1
7.1
TABLE: temperature rise measurements on Transmitter JBLSUBTX1 : Conditions
P
Power consumption in the OFF/Stand-by mode of the
functional switch (W)………..….:…………....:
functional switch (W)………..….:…………....:
No stand-by mode
P
Cond.
Un (V)
Hz
In (mA)
Pn (W)
V out
Pout (W)
Operating Condition
1 264 50 24 2.4
-
-
2 18 dc 90 1.62 -
-
-
1. Supplied from AC-adapter (mfr/type, see table 14)
2. Supplied from dc-power supply
2. Supplied from dc-power supply
Loudspeaker impedance (Ω) ..................................:
-
—
Several loudspeaker systems
-
—
Marking of loudspeaker terminals
—
—
Temperature Rise dT of Part
dT (K)
Limit max dT (K)
Test Condition No.
No 1
No ___
No ___
Top of enclosure, plastic
13
-
-
60 (50)
Bottom of enclosure, plastic
11
-
-
40 (30)
PCB 17
-
-
85
(75)
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ..............................
Ambient temperature t2 (
o
C) ..............................
-
-
— — —
—
Temperature rise dT of winding:
dT = (R
dT = (R
2
– R
1
) x (234.5 + t1) – (t2 – t1)
R
1
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit
maxK)
Insulation class
Note: The limit values in parenthesis are the limit values for tropical climate.
Page 27 of 58
Report No.: 1009950
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
7.2
TABLE: softening temperature of thermoplastics
P
Temperature T of part
T - normal con-
ditions (
o
C)
T - fault condi-
tions (
o
C)
Min T softening
(
o
C)
Mains fuse holder
<85
<85
>150
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
>10
Min 2
Between parts separated by basic or supplementary insulation
>10
Min 2
Between parts separated by double or reinforced insulation
>10
Min 4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120 pk
No
Between parts separated by basic or supplementary insulation
2120 pk
No
Between parts separated by double or reinforced insulation
4240 pk
No
Page 28 of 58
Report No.: 1009950
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage .............: 220-230
—
Ambient temperature (
o
C) .......................................: 25
—
No
Component
Fault
Temp Rise/
Component
Component
Other results
(include description and test duration)
(include description and test duration)
1
--
Pout = 100%
Transformer steel
washer:63K
PCB: 54K
enclosure: 53K
Rear metal enclosure:
40K
Un = 253V, In = 1.1A, Pn = 200W. After
52min the unit began switching ON/OFF
due to temp regulation on amplifier. After
2h mains fuse F1 opened due to short
circuit in speaker coil. (Tested with
transformer
52min the unit began switching ON/OFF
due to temp regulation on amplifier. After
2h mains fuse F1 opened due to short
circuit in speaker coil. (Tested with
transformer
TD-230-0300A+C)
No remarks
2
C19
sc
--
Un = 198V. F1 opened immediately.
No high temperature, no remarks.
No high temperature, no remarks.
3
Q11 d-g
sc
--
Un = 198V. F1 opened immediately.
Q10, Q10B, Q11 damaged. No high
temperature, no remarks.
Q10, Q10B, Q11 damaged. No high
temperature, no remarks.
4
R6
d
--
Un = 253V, Pn=111-172W. The unit
turned to standby mode after 1 min 50
sec. No high temperature, no remarks.
turned to standby mode after 1 min 50
sec. No high temperature, no remarks.
5
Q5B c-b
sc
--
Un = 253V, Pn= 60W. Uout decreased to
6.5V. The negative part of the output signal
disappeared. Test was interrupted after
5min. No high temperature, no remarks.
6.5V. The negative part of the output signal
disappeared. Test was interrupted after
5min. No high temperature, no remarks.
6a C134
sc
--
Un = 253V. R241 opened after 2s.
No high temperatures, no remarks.
No high temperatures, no remarks.
6b C134
sc
--
Un = 198V, Pn=9W. R241 heated. R241
lifted vertical from PCB. PCB=150K
(<210K), (PCB rated V0)
R241 opened after 16min. No high
temperatures, no remarks.
lifted vertical from PCB. PCB=150K
(<210K), (PCB rated V0)
R241 opened after 16min. No high
temperatures, no remarks.
7 C166
sc
--
Un = 253V, In = 127mA, Pn = 15W
Test time: 15min No high temperatures,
no remarks.
Test time: 15min No high temperatures,
no remarks.
8 C168
sc
--
Un = 198V
F1 opened immediately. No remarks.
F1 opened immediately. No remarks.
9 C170
sc
--
Un = 198V. R255 and R256 opened
immediately. No remarks.
immediately. No remarks.
10 Capacitor,
(600pF) in RC
snubber
sc
--
Un = 198/253V. Resistor, (18Ω) in RC
snubber opened immediately. No remarks.
snubber opened immediately. No remarks.
11 D124
~to+
sc
--
Un = 198V. Normal operation. Test time
15 min. No high temperatures, no
remarks.
15 min. No high temperatures, no
remarks.
12 C503
on wireless
board
sc
--
198V. Resistor R505 (10ohm) opened
immediately. No remarks.
immediately. No remarks.
Page 29 of 58
Report No.: 1009950
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
13 U501
pin 1-8
on wireless
board
sc
--
198V. Resistor R505 (10ohm) opened
immediately. No remarks
immediately. No remarks
Transmitter JBLSUBTX1 supplied from external dc-power supply (Iin limited to 20A)
14
C07
sc
-
Uin=18V Iin=0.18A Test time 5min.
No high temperatures. No remarks
No high temperatures. No remarks
15
C04
sc
-
Uin=18V Iin=0.2A Test time 5min.
No high temperatures. No remarks
No high temperatures. No remarks
16
C03
sc
-
Uin=18V Iin=1.2A Test time 5min.
After 3s interruption in Q01, which was
damaged.
No high temperatures. No remarks
After 3s interruption in Q01, which was
damaged.
No high temperatures. No remarks
17
Q01 c-e
sc
-
Uin=18V Iin=0.09A Test time 5min.
No high temperatures. No remarks
No high temperatures. No remarks
18
C02
sc
-
Uin=18V Iin=15.5A Test time 5min.
After 7s interruption in D01.
No high temperatures. No remarks
After 7s interruption in D01.
No high temperatures. No remarks
Standby PCB
19
C10
sc
TR1 winding / 67K
Un=253V, Pn = 5.5W, In = 0.065A Relay
switched OFF. No remarks
switched OFF. No remarks
20
D2
d -
Un=253V, Pn = 0.3W
Protection mode immediately. No remarks
Protection mode immediately. No remarks
21
D2
sc -
Un=253V, Pn = 45W
Normal function. No remarks
Normal function. No remarks
22
D6
d -
Un=253V, Pn = 47W
Normal function. No remarks
Normal function. No remarks
23
IC1
(5-8)
sc -
Un=198V, Pn = 0W,
Mains Fuse on Standby PCB opened
immediately; Optocoupler OP1 intact.
No Remarks
Mains Fuse on Standby PCB opened
immediately; Optocoupler OP1 intact.
No Remarks
Click on the first or last page to see other ES 150PW (serv.man5) service manuals if exist.